Abstract: As biometric systems become widely deployed, the security of identification systems can be easily attacked by various spoof materials. This paper contributes to finding a reliable and practical anti-spoofing method using Convolutional Neural Networks (CNNs) based on the types of loss functions and optimizers. The types of CNNs used in this paper include AlexNet, VGGNet, and ResNet. By using various loss functions including Cross-Entropy, Center Loss, Cosine Proximity, and Hinge Loss, and various loss optimizers which include Adam, SGD, RMSProp, Adadelta, Adagrad, and Nadam, we obtained significant performance changes. We realize that choosing the correct loss function for each model is crucial since different loss functions lead to different errors on the same evaluation. By using a subset of the Livdet 2017 database, we validate our approach to compare the generalization power. It is important to note that we use a subset of LiveDet and the database is the same across all training and testing for each model. This way, we can compare the performance, in terms of generalization, for the unseen data across all different models. The best CNN (AlexNet) with the appropriate loss function and optimizers result in more than 3% of performance gain over the other CNN models with the default loss function and optimizer. In addition to the highest generalization performance, this paper also contains the models with high accuracy associated with parameters and mean average error rates to find the model that consumes the least memory and computation time for training and testing. Although AlexNet has less complexity over other CNN models, it is proven to be very efficient. For practical anti-spoofing systems, the deployed version should use a small amount of memory and should run very fast with high anti-spoofing performance. For our deployed version on smartphones, additional processing steps, such as quantization and pruning algorithms, have been applied in our final model.
Abstract: During the process of the industrialization of steel structure housing, a composite structural system with separated gravity and lateral resistant systems has been applied in engineering practices, which consists of composite frame with hinged beam-column joints, steel brace and RC shear wall. As an attempt in steel structural system area, seismic performance evaluation of the separated composite structure is important for further application in steel housing. This paper focuses on the seismic performance comparison of the separated composite structural system and traditional steel frame-shear wall system under the same inter-story drift ratio (IDR) provision limit. The same architectural layout of a high-rise building is designed as two different structural systems at the same IDR level, and finite element analysis using pushover method is carried out. Static pushover analysis implies that the separated structural system exhibits different lateral deformation mode and failure mechanism with traditional steel frame-shear wall system. Different indexes are adopted and discussed in seismic performance evaluation, including IDR, safe factor (SF), shear wall damage, etc. The performance under maximum considered earthquake (MCE) demand spectrum shows that the shear wall damage of two structural systems are similar; the separated composite structural system exhibits less plastic hinges; and the SF index value of the separated composite structural system is higher than the steel frame shear wall structural system.
Abstract: The relative motion of a robotic arm formed by homogeneous bars of different lengths and masses, hinged to each other is investigated. The first bar of the mechanism is articulated on a platform, considered initially fixed on the surface of the Earth, while for the second case the platform is considered to be in rotation with respect to the Earth. For both analyzed cases the motion equations are determined using the Lagrangian formalism, applied in its traditional form, valid with respect to an inertial reference system, conventionally considered as fixed. However, in the second case, a generalized form of the formalism valid with respect to a non-inertial reference frame will also be applied. The numerical calculations were performed using a MATLAB program.
Abstract: The principal objective of this study is the evaluation of the seismic performance of reinforced concrete frame structures, taking into account of the behavior laws, reflecting the real behavior of materials, using CASTEM2000 software. A finite element model used is based in modified Takeda model with Timoshenko elements for columns and beams. This model is validated on a Vecchio experimental reinforced concrete (RC) frame model. Then, a study focused on the behavior of a RC frame with three-level and three-story in order to visualize the positioning the plastic hinge (plastic rotation), determined from the curvature distribution along the elements. The results obtained show that the beams of the 1st and 2nd level developed a very large plastic rotations, or these rotations exceed the values corresponding to CP (Collapse prevention with cp qCP = 0.02 rad), against those developed at the 3rd level, are between IO and LS (Immediate occupancy and life Safety with qIO = 0.005 rad and rad qLS = 0.01 respectively), so the beams of first and second levels submit a very significant damage.
Abstract: In India, cooling loads in residential sector is a major contributor to its total energy consumption. Due to the increasing cooling need, the market penetration of air-conditioners is further expected to rise. Natural Ventilation (NV), however, possesses great potential to save significant energy consumption especially for residential buildings in moderate climates. As multifamily residential apartment buildings are designed by repetitive use of prototype designs, deriving individual NV based design prototype solutions for a combination of different wind incidence angles and orientations would provide significant opportunity to address the rise in cooling loads by residential sector. This paper presents the results of NV performance of a selected prototype apartment design with a cluster of four units in Pune, India, and an attempt to improve the NV performance through design modifications. The water table apparatus, a physical modelling tool, is used to study the flow patterns and simulate wind-induced NV performance. Quantification of NV performance is done by post processing images captured from video recordings in terms of percentage of area with good and poor access to ventilation. NV performance of the existing design for eight wind incidence angles showed that of the cluster of four units, the windward units showed good access to ventilation for all rooms, and the leeward units had lower access to ventilation with the bedrooms in the leeward units having the least access. The results showed improved performance in all the units for all wind incidence angles to more than 80% good access to ventilation. Some units showed an additional improvement to more than 90% good access to ventilation. This process of design and performance evaluation improved some individual units from 0% to 100% for good access to ventilation. The results demonstrate the ease of use and the power of the water table apparatus for performance-based design to simulate wind induced NV.
Abstract: This paper presents a numerical solution, namely limit and shakedown analysis, to predict the safety state of smart structures made of heterogeneous materials under unknown cyclic loadings, for instance, the flexure hinge in the micro-positioning stage driven by piezoelectric actuator. In combination of homogenization theory and finite-element method (FEM), the safety evaluation problem is converted to a large-scale nonlinear optimization programming for an acceptable bounded loading as the design reference. Furthermore, a general numerical scheme integrated with the FEM and interior-point-algorithm based optimization tool is developed, which makes the practical application possible.
Abstract: Increasing demand for large-sized Floating, Storage and Regasification Units (FSRUs) for oil and gas industries led to the development of novel geometric form of Buoyant Leg Storage and Regasification Platform (BLSRP). BLSRP consists of a circular deck supported by six buoyant legs placed symmetrically with respect to wave direction. Circular deck is connected to buoyant legs using hinged joints, which restrain transfer of rotational response from the legs to deck and vice-versa. Buoyant legs are connected to seabed using taut moored system with high initial pretension, enabling rigid body motion in vertical plane. Encountered environmental loads induce dynamic tether tension variations, which in turn affect stability of the platform. The present study investigates Mathieu stability of BLSRP under the postulated tether pullout cases by inducing additional tension in the tethers. From the numerical studies carried out, it is seen that postulated tether pullout on any one of the buoyant legs does not result in Mathieu type instability even under excessive tether tension. This is due to the presence of hinged joints, which are capable of dissipating the unbalanced loads to other legs. However, under tether pullout of consecutive buoyant legs, Mathieu-type instability is observed.
Abstract: In many applied engineering problems, structural analysis is usually conducted by assuming a rigid bed, while imposing the effect of structure bed flexibility can affect significantly on the structure response. This article focuses on investigation and evaluation of the effects arising from considering a soil-structure system in evaluation of dynamic characteristics of a steel structure with respect to elastic and inelastic behaviors. The recorded structure acceleration during Taiwan’s strong Chi-Chi earthquake on different floors of the structure was our evaluation criteria. The respective structure is an eight-story steel bending frame structure designed using a displacement-based direct method assuring weak beam - strong column function. The results indicated that different identification methods i.e. reverse Fourier transform or transfer functions, is capable to determine some of the dynamic parameters of the structure precisely, rather than evaluating all of them at once (mode frequencies, mode shapes, structure damping, structure rigidity, etc.). Response evaluation based on the input and output data elucidated that the structure first mode is not significantly affected, even considering the soil-structure interaction effect, but the upper modes have been changed. Also, it was found that the response transfer function of the different stories, in which plastic hinges have occurred in the structure components, provides similar results.
Abstract: An efficient method is developed for the response of a group of vertical, cylindrical fixed-head, finite length piles embedded in a homogeneous elastic stratum, subjected to harmonic force atop the pile group cap. Pile to pile interaction is represented through simplified beam-on-dynamic-Winkler-foundation (BDWF) with realistic frequency-dependent springs and dashpots. Pile group effect is considered through interaction factors. New closed-form expressions for interaction factors and curvature ratios atop the pile are extended by considering different boundary conditions at the tip of the piles (fixed, hinged). In order to investigate the fundamental characteristics of inertial bending strains in pile groups, inertial bending strains at the head of each pile are expressed in terms of slenderness ratio. The results of parametric study give valuable insight in understanding the behavior of fixed head pile groups in fundamental natural frequency of soil stratum.
Abstract: This paper focuses on parametric analysis of reinforced concrete structures equipped with supplemental damping braces. Practitioners still luck sufficient data for current design of damper added structures and often reduce the real model to a pure damper braced structure even if this assumption is neither realistic nor conservative. In the present study, the damping brace is modelled as made by a linear supporting brace connected in series with the viscous/hysteretic damper. Deformation capacity of existing structures is usually not adequate to undergo the design earthquake. In spite of this, additional dampers could be introduced strongly limiting structural damage to acceptable values, or in some cases, reducing frame response to elastic behavior. This work is aimed at providing useful considerations for retrofit of existing buildings by means of supplemental damping braces. The study explicitly takes into consideration variability of (a) relative frame to supporting brace stiffness, (b) dampers’ coefficient (viscous coefficient or yielding force) and (c) non-linear frame behavior. Non-linear time history analysis has been run to account for both dampers’ behavior and non-linear plastic hinges modelled by Pivot hysteretic type. Parametric analysis based on previous studies on SDOF or MDOF linear frames provide reference values for nearly optimal damping systems design. With respect to bare frame configuration, seismic response of the damper-added frame is strongly improved, limiting deformations to acceptable values far below ultimate capacity. Results of the analysis also demonstrated the beneficial effect of stiffer supporting braces, thus highlighting inadequacy of simplified pure damper models. At the same time, the effect of variable damping coefficient and yielding force has to be treated as an optimization problem.
Abstract: Beam-column connections play an important role in the reinforced concrete moment resisting frame (RCMRF), which is one of the most commonly used structural systems around the world. The premature failure of such connections would severely limit the seismic performance and increase the vulnerability of RCMRF. In the past decades, researchers primarily focused on investigating the structural behaviour and failure mechanisms of conventional beam-column joints, the beam width of which is either smaller than or equal to the column width, while studies in wide beam-column joints were scarce. This paper presents the preliminary experimental results of two full-scale exterior wide beam-column connections, which are mainly designed and detailed according to ACI 318-14 and ACI 352R-02, under reversed cyclic loading. The ratios of the design shear force to the nominal shear strength of these specimens are 1.0 and 1.7, respectively, so as to probe into differences of the joint shear strength between experimental results and predictions by design codes of practice. Flexural failure dominated in the specimen with ratio of 1.0 in which full-width plastic hinges were observed, while both beam hinges and post-peak joint shear failure occurred for the other specimen. No sign of premature joint shear failure was found which is inconsistent with ACI codes’ prediction. Finally, a modification of current codes of practice is provided to accurately predict the joint shear strength in wide beam-column joint.
Abstract: This paper presents a design and optimization for a compliant gripper. The gripper is constructed based on the concept of compliant mechanism with flexure hinge. A passive force regulation mechanism is presented to control the grasping force a micro-sized object instead of using a sensor force. The force regulation mechanism is designed using the planar springs. The gripper is expected to obtain a large range of displacement to handle various sized objects. First of all, the statics and dynamics of the gripper are investigated by using the finite element analysis in ANSYS software. And then, the design parameters of the gripper are optimized via Taguchi method. An orthogonal array L9 is used to establish an experimental matrix. Subsequently, the signal to noise ratio is analyzed to find the optimal solution. Finally, the response surface methodology is employed to model the relationship between the design parameters and the output displacement of the gripper. The design of experiment method is then used to analyze the sensitivity so as to determine the effect of each parameter on the displacement. The results showed that the compliant gripper can move with a large displacement of 213.51 mm and the force regulation mechanism is expected to be used for high precision positioning systems.
Abstract: This paper presents a robust software package for practical advanced analysis of space steel framed structures. The pre- and post-processors of the presented software package are coded in the C++ programming language while the solver is written by using the FORTRAN programming language. A user-friendly graphical interface of the presented software is developed to facilitate the modeling process and result interpretation of the problem. The solver employs the stability functions for capturing the second-order effects to minimize modeling and computational time. Both the plastic-hinge and fiber-hinge beam-column elements are available in the presented software. The generalized displacement control method is adopted to solve the nonlinear equilibrium equations.
Abstract: This paper deals with different modeling aspects of masonry infill: no infill model, Layered shell infill model, and strut infill model. These models consider the complicated behavior of the in-filled plane frames under lateral load similar to an earthquake load. Three strut infill models are used: NBCC (2005) strut infill model, ASCE/SEI 41-06 strut infill model and proposed strut infill model based on modification to Canadian, NBCC (2005) strut infill model. Pushover and modal analyses of a masonry infill concrete frame with a single storey and an existing 5-storey RC building have been carried out by using different models for masonry infill. The corresponding hinge status, the value of base shear at target displacement as well as their dynamic characteristics have been determined and compared. A validation of the structural numerical models for the existing 5-storey RC building has been achieved by comparing the experimentally measured and the analytically estimated natural frequencies and their mode shapes. This study shows that ASCE/SEI 41-06 equation underestimates the values for the equivalent properties of the diagonal strut while Canadian, NBCC (2005) equation gives realistic values for the equivalent properties. The results indicate that both ASCE/SEI 41-06 and Canadian, NBCC (2005) equations for strut infill model give over estimated values for dynamic characteristic of the building. Proposed modification to Canadian, NBCC (2005) equation shows that the fundamental dynamic characteristic values of the building are nearly similar to the corresponding values using layered shell elements as well as measured field results.
Abstract: In this paper, de Laval rotor system has been
characterized by a hinge model and its transient response numerically
treated for a dynamic solution. The effect of the ensuing non-linear
disturbances namely rub and breathing crack is numerically
simulated. Subsequently, three analysis methods: Orbit Analysis, Fast
Fourier Transform (FFT), and Wavelet Transform (WT) are
employed to extract features of the vibration signal of the faulty
system. An analysis of the system response orbits clearly indicates
the perturbations due to the rotor-to-stator contact. The sensitivities
of WT to the variation in system speed have been investigated by
Continuous Wavelet Transform (CWT). The analysis reveals that
features of crack, rubs and unbalance in vibration response can be
useful for condition monitoring. WT reveals its ability to detect nonlinear
signal, and obtained results provide a useful tool method for
detecting machinery faults.
Abstract: We consider the problem of stabilization of an unstable
heat equation in a 2-D, 3-D and generally n-D domain by deriving a
generalized backstepping boundary control design methodology. To
stabilize the systems, we design boundary backstepping controllers
inspired by the 1-D unstable heat equation stabilization procedure.
We assume that one side of the boundary is hinged and the other
side is controlled for each direction of the domain. Thus, controllers
act on two boundaries for 2-D domain, three boundaries for 3-D
domain and ”n” boundaries for n-D domain. The main idea of the
design is to derive ”n” controllers for each of the dimensions by
using ”n” kernel functions. Thus, we obtain ”n” controllers for the
”n” dimensional case. We use a transformation to change the system
into an exponentially stable ”n” dimensional heat equation. The
transformation used in this paper is a generalized Volterra/Fredholm
type with ”n” kernel functions for n-D domain instead of the one
kernel function of 1-D design.
Abstract: Environmental and functional conditions, sometimes,
necessitate the architectural plan of the building to be asymmetric,
and this result in an asymmetric structure. In such cases finding an
optimal pattern for locating the components of lateral load bearing
system, including shear walls, in the building’s plan is desired. In
case of shear wall in addition to the location the shape of the wall
cross-section is also an effective factor. Various types of shear walls
and their proper layout might come effective in better stiffness
distribution and more appropriate seismic response of the building.
Several studies have been conducted in the context of analysis and
design of shear walls; however, few studies have been performed on
making decisions for the location and form of shear walls in multistory
buildings, especially those with irregular plan. In this study, an
attempt has been made to obtain the most reliable seismic behavior of
multi-story reinforced concrete vertically chamfered buildings by
using more appropriate shear walls form and arrangement in 7-, 10-,
12-, and 15-stoy buildings. The considered forms and arrangements
include common rectangular walls and L-, T-, U- and Z-shaped plan,
located as the core or in the outer frames of the building structure.
Comparison of seismic behaviors of the buildings, including
maximum roof displacement and particularly formation of plastic
hinges and their distribution in the buildings’ structures, have been
done based on the results of a series of nonlinear time history
analyses, by using a set of selected earthquake records. Results show
that shear walls with U-shaped cross-section, placed as the building
central core, and also walls with Z-shaped cross-section, placed at the
corners give the building more reliable seismic behavior.
Abstract: This paper presents a methodology for probabilistic
assessment of bearing capacity and prediction of failure mechanism
of masonry vaults at the ultimate state with consideration of the
natural variability of Young’s modulus of stones. First, the
computation model is explained. The failure mode corresponds to the
four-hinge mechanism. Based on this consideration, the study of a
vault composed of 16 segments is presented. The Young’s modulus of
the segments is considered as random variable defined by a mean
value and a coefficient of variation. A relationship linking the vault
bearing capacity to the voussoirs modulus variation is proposed. The
most probable failure mechanisms, in addition to that observed in the
deterministic case, are identified for each variability level as well as
their probability of occurrence. The results show that the mechanism
observed in the deterministic case has decreasing probability of
occurrence in terms of variability, while the number of other
mechanisms and their probability of occurrence increases with the
coefficient of variation of Young’s modulus. This means that if a
significant change in the Young’s modulus of the segments is proven,
taking it into account in computations becomes mandatory, both for
determining the vault bearing capacity and for predicting its failure
mechanism.
Abstract: Currently there are many use of threaded reinforcing
bars in construction fields because those do not need additional screw
processing when connecting reinforcing bar by threaded coupler. In
this study, reinforced concrete bridge piers using threaded rebar
coupler system at the plastic hinge area were tested to evaluate seismic
performance. The test results showed that threads of the threaded rebar
coupler system could be loosened while under tension-compression
cyclic loading because tolerance and rib face angle of a threaded rebar
coupler system are greater than that of a conventional ribbed rebar
coupler system. As a result, cracks were concentrated just outside of
the mechanical coupler and stiffness of reinforced concrete bridge pier
decreased. Therefore, it is recommended that connection ratio of
mechanical couplers in one section shall be below 50% in order that
cracks are not concentrated just outside of the mechanical coupler.
Also, reduced stiffness of the specimen should be considered when
using the threaded rebar coupler system.
Abstract: Failure of typical seismic frames has been found by
plastic hinge occurring on beams section near column faces. On the
other hand, the seismic capacity of the frames can be enhanced if the
plastic hinges of the beams are shifted away from the column faces.
This paper presents detailing of reinforcements in the interior beam–
column connections aiming to relocate the plastic hinge of reinforced
concrete and precast concrete frames. Four specimens were tested
under quasi-static cyclic load including two monolithic specimens
and two precast specimens. For one monolithic specimen, typical
seismic reinforcement was provided and considered as a reference
specimen named M1. The other reinforced concrete frame M2
contained additional intermediate steel in the connection area
compared with the specimen M1. For the precast specimens,
embedded T-section steels in joint were provided, with and without
diagonal bars in the connection area for specimen P1 and P2,
respectively. The test results indicated the ductile failure with beam
flexural failure in monolithic specimen M1 and the intermediate steel
increased strength and improved joint performance of specimen M2.
For the precast specimens, cracks generated at the end of the steel
inserts. However, slipping of reinforcing steel lapped in top of the
beams was seen before yielding of the main bars leading to the brittle
failure. The diagonal bars in precast specimens P2 improved the
connection stiffness and the energy dissipation capacity.