Abstract: The thermal control in many systems is widely
accomplished applying mixed convection process due to its low cost,
reliability and easy maintenance. Typical applications include the
aircraft electronic equipment, rotating-disc heat exchangers, turbo
machinery, and nuclear reactors, etc. Natural convection in an inclined
square enclosure heated via wall heater has been studied numerically.
Finite volume method is used for solving momentum and energy
equations in the form of stream function–vorticity. The right and left
walls are kept at a constant temperature, while the other parts are
adiabatic. The range of the inclination angle covers a whole revolution.
The method is validated for a vertical cavity. A general power law
dependence of the Nusselt number with respect to the Rayleigh
number with the coefficient and exponent as functions of the
inclination angle is presented. For a fixed Rayleigh number, the
inclination angle increases or decreases is found.
Abstract: Meeting the growth in demand for digital services
such as social media, telecommunications, and business and cloud
services requires large scale data centres, which has led to an increase
in their end use energy demand. Generally, over 30% of data centre
power is consumed by the necessary cooling overhead. Thus energy
can be reduced by improving the cooling efficiency. Air and liquid
can both be used as cooling media for the data centre. Traditional
data centre cooling systems use air, however liquid is recognised as a
promising method that can handle the more densely packed data
centres. Liquid cooling can be classified into three methods; rack heat
exchanger, on-chip heat exchanger and full immersion of the
microelectronics. This study quantifies the improvements of heat
transfer specifically for the case of immersed microelectronics by
varying the CPU and heat sink location. Immersion of the server is
achieved by filling the gap between the microelectronics and a water
jacket with a dielectric liquid which convects the heat from the CPU
to the water jacket on the opposite side. Heat transfer is governed by
two physical mechanisms, which is natural convection for the fixed
enclosure filled with dielectric liquid and forced convection for the
water that is pumped through the water jacket. The model in this
study is validated with published numerical and experimental work
and shows good agreement with previous work. The results show that
the heat transfer performance and Nusselt number (Nu) is improved
by 89% by placing the CPU and heat sink on the bottom of the
microelectronics enclosure.
Abstract: This article is trying to determine the status of flue gas
that is entering the KWH heat exchanger from combustion chamber
in order to calculate the heat transfer ratio of the heat exchanger.
Combination of measurement, calculation and computer simulation
was used to create a useful way to approximate the heat transfer rate.
The measurements were taken by a number of sensors that are
mounted on the experimental device and by a thermal imaging
camera. The results of the numerical calculation are in a good
correspondence with the real power output of the experimental
device. That result shows that the research has a good direction and
can be used to propose changes in the construction of the heat
exchanger, but still needs enhancements.
Abstract: A thermosyphon system is a heat transfer loop which
operates on the basis of gravity and buoyancy forces. It guarantees a
good reliability and low maintenance cost as it does not involve any
mechanical pump. Therefore, it can be used in many industrial
applications such as refrigeration and air conditioning, electronic
cooling, nuclear reactors, geothermal heat extraction, etc. But flow
instabilities and loop configuration are the major problems in this
system. Several previous researchers studied that stabilities can be
suppressed by using nanofluids as loop fluid. In the present study a
rectangular thermosyphon loop with end heat exchangers are
considered for the study. This configuration is more appropriate for
many practical applications such as solar water heater, geothermal
heat extraction, etc. In the present work, steady-state analysis is
carried out on thermosyphon loop with parallel flow coaxial heat
exchangers at heat source and heat sink. In this loop nanofluid is
considered as the loop fluid and water is considered as the external
fluid in both hot and cold heat exchangers. For this analysis onedimensional
homogeneous model is developed. In this model,
conservation equations like conservation of mass, momentum, energy
are discretized using finite difference method. A computer code is
written in MATLAB to simulate the flow in thermosyphon loop. A
comparison in terms of heat transfer is made between water and
nanofluid as working fluids in the loop.
Abstract: Cross flow water tube heat exchanger can be designed
and made operational using methods of model building and
simulation of the system. This paper projects the design and
development of a model of cross flow water tube heat-exchanger
system, simulation and validation of control analysis of different
tuning methods. Feedback and override control system is developed
using inputs acquired with the help of sensory system. A
mathematical model is formulated for analysis of system behaviour.
The temperature is regulated at the desired set point automatically.
Abstract: Solar air heater is a type of heat exchanger which
transforms solar radiation into heat energy. The thermal performance
of conventional solar air heater has been found to be poor because of
the low convective heat transfer coefficient from the absorber plate to
the air. It is attributed to the formation of a very thin boundary layer
at the absorber plate surface commonly known as viscous sub-layer.
Thermal efficiency of solar air heater can be improved by providing
the artificial roughness on absorber plate is the most efficient
technique. In this paper an attempt is made to provide artificial
roughness by incorporating inclined multiple V-ribs in the underside
of the absorber plate. 60˚V – ribs are arranged inclined to the
direction of air flow. Performance of collector estimated theoretically
and experimentally. Results of the investigation reveal that thermal
efficiency of collector with multiple V-ribs increased by 14%.
Abstract: Using cold EGR method with variable venturi and
turbocharger has a very significant effect on reduction of NOX and
grime simultaneously. EGR cooler is one of the most important parts
in the cold EGR circuit. In this paper optimum design of cooler for
working in different percentages of EGR and for determining
optimum temperature of exhausted gases, growth of efficiency,
reduction of weight, dimension, expenditures, sediment and also
optimum performance by using gasoil which has significant amounts
of brimstone are investigated and optimized.
Abstract: The thermo-mechanical behaviour of concrete energy
pile foundations with different single and double U-tube shapes
incorporated was analysed using the Comsol Multi-physics package.
For the analysis, a 3D numerical model in real scale of the concrete
pile and surrounding soil was simulated regarding actual operation of
ground heat exchangers (GHE) and the surrounding ambient
temperature. Based on initial ground temperature profile measured in
situ, tube inlet temperature was considered to range from 6oC to 0oC
(during the contraction process) over a 30-day period. Extra thermal
stresses and deformations were calculated during the simulations and
differences arising from the use of two different systems (single-tube
and double-tube) were analysed. The results revealed no significant
difference for extra thermal stresses at the centre of the pile in either
system. However, displacements over the pile length were found to
be up to 1.5-fold higher in the double-tube system than the singletube
system.
Abstract: Heat transfer from flat tube is studied numerically. Reynolds number is defined base on equivalent circular tube which is varied in range of 100 to 300. In these range of Reynolds number flow is considered to be laminar, unsteady, and incompressible. Equations are solved by using finite volume method. Results show that increasing l/D from 1 to 2 has insignificant effect on heat transfer and Nusselt number of flat tube is slightly lower than circular tube. However, thermal-hydraulic performance of flat tube is up to 2.7 times greater than circular tube.
Abstract: In industrial environments, the heat exchanger is a
necessary component to any strategy of energy conversion. Much of
thermal energy used in industrial processes passes at least one times
by a heat exchanger, and methods systems recovering thermal
energy.
This survey paper tries to presents in a systemic way an sample
control of a heat exchanger by comparison between three controllers
LQR (linear quadratic regulator), PID (proportional, integrator and
derivate) and Pole Placement. All of these controllers are used mainly
in industrial sectors (chemicals, petrochemicals, steel, food
processing, energy production, etc…) of transportation (automotive,
aeronautics), but also in the residential sector and tertiary (heating, air
conditioning, etc...) The choice of a heat exchanger, for a given
application depends on many parameters: field temperature and
pressure of fluids, and physical properties of aggressive fluids,
maintenance and space. It is clear that the fact of having an
exchanger appropriate, well-sized, well made and well used allows
gain efficiency and energy processes.
Abstract: The subject of this paper is the design analysis of a single well power production unit from low enthalpy geothermal resources. A complexity of the project is defined by a low temperature heat source that usually makes such projects economically disadvantageous using the conventional binary power plant approach. A proposed new compact design is numerically analyzed. This paper describes a thermodynamic analysis, a working fluid choice, downhole heat exchanger (DHE) and turbine calculation results. The unit is able to produce 321 kW of electric power from a low enthalpy underground heat source utilizing n-Pentane as a working fluid. A geo-pressured reservoir located in Vermilion Parish, Louisiana, USA is selected as a prototype for the field application. With a brine temperature of 126 , the optimal length of DHE is determined as 304.8 m (1000ft). All units (pipes, turbine, and pumps) are chosen from commercially available parts to bring this project closer to the industry requirements. Numerical calculations are based on petroleum industry standards. The project is sponsored by the Department of Energy of the US.
Abstract: The problem of magnetohydrodynamics boundary layer flow and heat transfer on a permeable stretching surface in a second grade nanofluid under the effect of heat generation and partial slip is studied theoretically. The Brownian motion and thermophoresis effects are also considered. The boundary layer equations governed by the PDE’s are transformed into a set of ODE’s with the help of local similarity transformations. The differential equations are solved by variational finite element method. The effects of different controlling parameters on the flow field and heat transfer characteristics are examined. The numerical results for the dimensionless velocity, temperature and nanoparticle volume fraction as well as the reduced Nusselt and Sherwood number have been presented graphically. The comparison confirmed excellent agreement. The present study is of great interest in coating and suspensions, cooling of metallic plate, oils and grease, paper production, coal water or coal-oil slurries, heat exchangers technology, materials processing exploiting.
Abstract: The ice rink floor is the largest heat exchanger in an ice rink. The important part of the floor consists of concrete, and the thermophysical properties of this concrete have strong influence on the energy usage of the ice rink. The thermal conductivity of concrete can be increased by using iron ore as ballast. In this study, the Transient Plane Source (TPS) method showed an increase up to 58.2% of thermal conductivity comparing the improved concrete to standard concrete. Moreover, two alternative ice rink floor designs are suggested to incorporate the improved concrete. A 2D simulation was developed to investigate the temperature distribution in the conventional and the suggested designs. The results show that the suggested designs reduce the temperature difference between the ice surface and the brine by 1-4˚C, when comparing with convectional designs at equal heat flux. This primarily leads to an increased coefficient of performance (COP) in the primary refrigeration cycle and secondly to a decrease in the secondary refrigerant pumping power. The suggested designs have great potential to reduce the energy usage of ice rinks. Depending on the load scenario in the ice rink, the saving potential lies in the range of 3-10% of the refrigeration system energy usage. This calculation is based on steady state conditions and the potential with improved dynamic behavior is expected to increase the potential saving.
Abstract: Distillation consumes enormous quantity of energy. This work proposed a process to recover the energy from exit streams during the distillation process of three consecutive columns. There are several novel techniques to recover the heat with the distillation system; however, a complex control system is required. This work proposed a simpler technique by exchanging the heat between streams without interrupting the internal distillation process that might cause a serious control problem. The proposed process is executed by using heat exchanger network with pinch analysis to maximize the process heat recovery. The test model is the distillation of butane, pentane, hexane, and heptanes, which is a common mixture in the petroleum refinery. This proposed process saved the energy consumption for hot and cold utilities of 29 and 27%, which is considered significant. Therefore, the recovery of heat from exit streams from distillation process is proved to be effective for energy saving.
Abstract: Flows developed between two parallel disks have
many engineering applications. Two types of non-swirling flows can
be generated in such a domain. One is purely source flow in disc type
domain (outward flow). Other is purely sink flow in disc type domain
(inward flow). This situation often appears in some turbo machinery
components such as air bearings, heat exchanger, radial diffuser,
vortex gyroscope, disc valves, and viscosity meters. The main goal of
this paper is to show the mesh convergence, because mesh
convergence saves time, and economical to run and increase the
efficiency of modeling for both sink and source flow. Then flow field
is resolved using a very fine mesh near-wall, using enhanced wall
treatment. After that we are going to compare this flow using
standard k-epsilon, RNG k-epsilon turbulence models. Lastly
compare some experimental data with numerical solution for sink
flow. The good agreement of numerical solution with the
experimental works validates the current modeling.
Abstract: In the present time, energy crises is considered a severe problem across the world. For the protection of global environment and maintain ecological balance, energy saving is considered one of the most vital issues from the view point of fuel consumption. As the industrial sectors everywhere continue efforts to improve their energy efficiency, recovering waste heat losses provides an attractive opportunity for an emission free and less costly energy resource. In the other hand the using of solar energy has become more insistent particularly after the high gross of prices and running off the conventional energy sources. Therefore, it is essential that we should endeavor for waste heat recovery as well as solar energy by making significant and concrete efforts. For these reasons this investigation is carried out to study and analyze the performance of a power plant working by a combined cycle in which heat recovery system generator (HRSG) gets its energy from the waste heat of a gas turbine unit. Evaluation of the performance of the plant is based on different thermal efficiencies of the main components in addition to the second law analysis considering the exergy destructions for the whole components. The contribution factors including the solar as well as the wasted energy are considered in the calculations. The final results have shown that there is significant exergy destruction in solar concentrator and the combustion chamber of the gas turbine unit. Other components such as compressor, gas turbine, steam turbine and heat exchangers having insignificant exergy destruction. Also, solar energy can contribute by about 27% of the input energy to the plant while the energy lost with exhaust gases can contribute by about 64% at maximum cases.
Abstract: This paper deals with the conceptual design of Experimental Helium Cooling Loop (EHCL) for Indian Test Blanket Module (TBM) and its related thermal hydraulic experiments. Indian TBM team is developing Lead Lithium cooled Ceramic Breeder (IN-LLCB) TBM to be tested in ITER. The TBM box structure is cooled by high pressure (8 MPa) and high temperature (300-500C) helium gas.
The first wall of TBM made of complex channel geometry having several parallel channels carrying helium gas for efficient heat extraction. Several mock-ups of these channels need to be tested before finalizing the TBM first wall design and fabrication. Besides the individual testing of such mock-ups of breeding blanket, the testing of Pb-Li to helium heat exchanger, the operational experience of helium loop and understanding of the behavior of high pressure and high temperature system components are very essential for final development of Helium Cooling System for LLCB TBM in ITER. The main requirements and characteristics of the EHCL and its conceptual design are presented in this paper.
Abstract: Ground Coupled Heat Pumps (GCHPs) exploit effectively the heat capacity of the ground, with the use of Ground Heat Exchangers (GHE). Depending on the mode of operation of the GCHPs, GHEs dissipate or absorb heat from the ground. For sizing the GHE the thermal properties of the ground need to be known. This paper gives information about the density, thermal conductivity, specific heat and thermal diffusivity of various lithologies encountered in Cyprus with various relations between these properties being examined through comparison and modeling. The results show that the most important correlation is the one encountered between thermal conductivity and thermal diffusivity with both properties showing similar response to the inlet and outlet flow temperature of vertical and horizontal heat exchangers.
Abstract: This paper presents experimental investigation carried out on an unmodified four stroke diesel engine running with preheated straight vegetable oil (SVO) of Karanja. The viscosity of straight karanja oil was reduced by preheating the oil up to 1600C under different load condition. The preheating was done with the help of a Shell and Tube heat exchanger equipment without using any external power source. The heat exchanger was designed in the lab and the heating source was by waste exhaust gas from engine. The experimental results data were analyzed by using 20% blends of svo of Karanja with 80% diesel by volume and 100% preheated svo of karanja for various parameters like specific fuel consumption, brake thermal efficiency and emission of exhaust gas like CO, CO2, HC and NOx. The results indicated that by using straight karanja oil, the emission parameter increases as compared to diesel but regarding engine performance it was found to be very close to that of diesel. All total it can be a replacement of diesel with a small efficiency drop.
Abstract: Finned-tube heat exchangers are predominantly used in space conditioning systems, as well as other applications requiring heat exchange between two fluids. The design of finned-tube heat exchangers requires the selection of over a dozen design parameters by the designer such as tube pitch, tube diameter, tube thickness, etc… Finned-tube heat exchangers are common devices; however, their performance characteristics are complicated. In this paper numerical studies have been carried out to analyze the performances of finned tube heat exchanger (without fins considered for experimental purpose) by predicting the characteristics of temperature difference and pressure drop. In this study, a design considering 5 design variables and also maximizing the temperature difference and pressure drop was suggested by applying DOE. During this process, L18 orthogonal array was adopted. Parametric analytical studies have been carried out using ANOVA to determine the relative importance of each variable with respect to the temperature difference and the pressure drop. Following the results, the final design was suggested by predicting the optimum design therefore confirming the optimized condition.