Abstract: Amoxicillin is an antibiotic which is widely used to
treat various infections in both human beings and animals. However,
when amoxicillin is released into the environment, it is a major
problem. Amoxicillin causes bacterial resistance to these drugs and
failure of treatment with antibiotics. Liquid membrane is of great
interest as a promising method for the separation and recovery of the
target ions from aqueous solutions due to the use of carriers for the
transport mechanism, resulting in highly selectivity and rapid
transportation of the desired metal ions. The simultaneous processes
of extraction and stripping in a single unit operation of liquid
membrane system are very interesting. Therefore, it is practical to
apply liquid membrane, particularly the HFSLM for industrial
applications as HFSLM is proved to be a separation process with
lower capital and operating costs, low energy and extractant with
long life time, high selectivity and high fluxes compared with solid
membranes. It is a simple design amenable to scaling up for industrial
applications. The extraction and recovery for (Amoxicillin) through
the hollow fiber supported liquid membrane (HFSLM) using
aliquat336 as a carrier were explored with the experimental data. The
important variables affecting on transport of amoxicillin viz.
extractant concentration and operating time were investigated. The
highest AMOX- extraction percentages of 85.35 and Amoxicillin
stripping of 80.04 were achieved with the best condition at 6 mmol/L
[aliquat336] and operating time 100 min. The extraction reaction
order (n) and the extraction reaction rate constant (kf) were found to
be 1.00 and 0.0344 min-1, respectively.
Abstract: The separation of silver ions from medicinal wastewater via hollow fiber supported liquid membrane (HFSLM) was examined to promote the performance of this technique. The wastewater consisting of 30mg/L silver ions and 120mg/L ferric ions was used as the feed solution. LIX84I dissolving in kerosene and sodium thiosulfate pentahydrate solution were used as the liquid membrane and stripping solution, respectively. In order to access the highest performance of HFSLM, the optimum condition was investigated via several influential variables. Final concentration of silver ions in feed solution was obtained 0.2mg/L which was lower than the discharge limit of Thailand’s mandatory.
Abstract: A double module hollow fiber supported liquid
membrane (HFSLM) was applied to selectively separate lead and
mercury ions from dilute synthetic produced water. The experiments
were investigated on several variables: types of extractants
(D2EHPA, Cyanex 471, Aliquat 336, and TOA), concentration of the
selected extractant and operating time. The results clearly showed
that the double module HFSLM could selectively separate Pb(II) and
Hg(II) in feed solution at a very low concentration to less than the
regulatory discharge limit of 0.2 and 0.005 mg/L issued by the
Ministry of Industry and the Ministry of Natural Resource
Environment, Thailand. The highest extractions of lead and mercury
ions from synthetic produced water were 96% and 100% using 0.03
M D2EHPA and 0.06 M Aliquat 336 as the extractant for the first
and second modules.