Abstract: The thermal conductivity of thermal insulation materials are measured by Heat Flow Meter (HFM) apparatus. The components of uncertainty are complex and difficult on routine measurement by modelling approach. In this study, uncertainty of thermal conductivity measurement was estimated by single laboratory validation approach. The within-laboratory reproducibility was 1.1%. The standard uncertainty of method and laboratory bias by using SRM1453 expanded polystyrene board was dominant at 1.4%. However, it was assessed that there was no significant bias. For sample measurement, the sources of uncertainty were repeatability, density of sample and thermal conductivity resolution of HFM. From this approach to sample measurements, the combined uncertainty was calculated. In summary, the thermal conductivity of sample, polystyrene foam, was reported as 0.03367 W/m·K ± 3.5% (k = 2) at mean temperature 23.5 °C. The single laboratory validation approach is simple key of routine testing laboratory for estimation uncertainty of thermal conductivity measurement by using HFM, according to ISO/IEC 17025-2017 requirements. These are meaningful for laboratory competent improvement, quality control on products, and conformity assessment.
Abstract: This research involved the utilization of fluid flow energy to predict power output using Lead Zirconate Titanate (PZT) piezoelectric stacks. The aim of this work is to extract energy from a controlled level of pressure fluctuation in single-phase flow which forms a part of the energy harvesting technology that powers flow meters. A device- Perspex box was developed and fixed to 50.8 mm rig to induce pressure fluctuation in the flow. An experimental test was carried out using the single-phase water flow in the developed rig in order to measure the power output generation from the piezoelectric stacks. 16 sets of experimental tests were conducted to ensure the maximum output result. The acquired signal of the pressure fluctuation was used to simulate the expected electrical output from the piezoelectric material. The results showed a maximum output voltage of 12 V with an instantaneous output power of 1 µW generated, when the pressure amplitude is 2.6 kPa at a frequency of 2.4 Hz.
Abstract: A prospective double-blind placebo controlled trial carried out on 60 children known to be asthmatic who presented to the emergency department at Alexandria University of Children’s Hospital at El-Shatby with acute asthma exacerbations to assess the efficacy of adding inhaled magnesium sulfate to β-agonist, compared with β-agonist in saline, in the management of acute asthma exacerbations in children. The participants in the study were divided in two groups; Group A (study group) received inhaled salbutamol solution (0.15 ml/kg) plus isotonic magnesium sulfate 2 ml in a nebulizer chamber. Group B (control group): received nebulized salbutamol solution (0.15 ml/kg) diluted with placebo (2 ml normal saline). Both groups received inhaled solution every 20 minutes that was repeated for three doses. They were evaluated using the Pediatric Asthma Severity Score (PASS), oxygen saturation using portable pulse oximetry and peak expiratory flow rate using a portable peak expiratory flow meter at initially recorded as zero-minute assessment and every 20 minutes from the end of each nebulization (nebulization lasts 5-10 minutes) recorded as 20, 40 and 60-minute assessments. Regarding PASS, comparison showed non-significant difference with p-value 0.463, 0.472, 0.0766 at 20, 40 and 60 minutes. Regarding oxygen saturation, improvement was more significant towards group A starting from 40 min with significant p-value=0.000. At 60 min p-value=0.000. Although mean PEFR significantly improved from zero-min in both groups; however, improvement was more significant in group A with significant p-value = 0.015, 0.001, 0.001 at 20 min, 40 min and 60 min, respectively. The conclusion this study suggests is that inhaled magnesium sulfate is an efficient add on drug to standard β- agonist inhalation used in the treatment of moderate to severe asthma exacerbations.
Abstract: Present study was aimed to develop a discharge
measuring device for irrigation and laboratory channels. Experiments
were conducted on sharp edged constricted flow meters having four
types of width constrictions namely 2:1, 1.5:1, 1:1 and 90o in the
direction of flow. These devices were made of MS sheets and
installed separately in a rectangular flume. All these four devices
were tested under free and submerged flow conditions. Eight
different discharges varying from 2 lit/sec to 30 lit/sec were passed
through each device. In total around 500 observations of upstream
and downstream depths were taken in the present work. For each
discharge, free submerged and critical submergence under different
flow conditions were noted and plotted. Once the upstream and
downstream depths of flow over any of the device are known, the
discharge can be easily calculated with the help of the curves
developed for free and submerged flow conditions. The device
having contraction 2:1 is the most efficient one as it allows maximum
critical submergence.
Abstract: Background: Diabetic sensorimotor polyneuropathy
(DSP) is one of the most common microvascular complications of
type 2 diabetes. Loss of sensation is thought to contribute to a lack of
static and dynamic stability and increased risk of falling. Purpose:
The purpose of this study was to compare the effects of low-level
laser (LLL) and monochromatic near-infrared photo energy (MIRE)
on pain, cutaneous sensation, static stability, and index of lower limb
blood flow in diabetic patients with peripheral neuropathy. Methods:
Forty diabetic patients with peripheral neuropathy were recruited for
participation in this study. They were divided into two groups: The
MIRE group, which contained 20 patients, and the LLL group, which
contained 20 patients. All patients who participated in the study had
been subjected to various physical assessment procedures, including
pain, cutaneous sensation, Doppler flow meter, and static stability
assessments. The baseline measurements were followed by treatment
sessions that were conducted twice a week for six successive weeks.
Results: The statistical analysis of the data revealed significant
improvement of pain in both groups, with significant improvement in
cutaneous sensation and static balance in the MIRE group compared
to the LLL group; on the other hand, the results showed no
significant differences in lower limb blood flow between the groups.
Conclusion: LLL and MIRE can improve painful symptoms in
patients with diabetic neuropathy. On the other hand, MIRE is also
useful in improving cutaneous sensation and static stability in
patients with diabetic neuropathy.
Abstract: This paper outlines the basic installation and operation of magnetic inductive flow velocity sensors on large underground cooling water pipelines. Research on the effects of cathodic protection as well as into other factors that might influence the overall performance of the meter is presented in this paper. The experiments were carried out on an immersion type magnetic meter specially used for flow measurement of cooling water pipeline. An attempt has been made in this paper to outline guidelines that can ensure accurate measurement related to immersion type magnetic meters on underground pipelines.
Abstract: Electromagnetic flow meter by measuring the varying of magnetic flux, which is related to the velocity of conductive flow, can measure the rate of fluids very carefully and precisely. Electromagnetic flow meter operation is based on famous Faraday's second Law. In these equipments, the constant magnetostatic field is produced by electromagnet (winding around the tube) outside of pipe and inducting voltage that is due to conductive liquid flow is measured by electrodes located on two end side of the pipe wall. In this research, we consider to 2-dimensional mathematical model that can be solved by numerical finite difference (FD) solution approach to calculate induction potential between electrodes. The fundamental concept to design the electromagnetic flow meter, exciting winding and simulations are come out by using MATLAB and PDE-Tool software. In the last stage, simulations results will be shown for improvement and accuracy of technical provision.
Abstract: Nozzle is the main part of various spinning systems
such as air-jet and Murata air vortex systems. Recently, many
researchers worked on the usage of the nozzle on different spinning
systems such as conventional ring and compact spinning systems. In
these applications, primary purpose is to improve the yarn quality. In
present study, it was produced the yarns with two different nozzle
types and determined the changes in yarn properties. In order to
explain the effect of the nozzle, airflow structure in the nozzle was
modelled and airflow variables were determined. In numerical
simulation, ANSYS 12.1 package program and Fluid Flow (CFX)
analysis method was used. As distinct from the literature, Shear
Stress Turbulent (SST) model is preferred. And also air pressure at
the nozzle inlet was measured by electronic mass flow meter and
these values were used for the simulation of the airflow. At last, the
yarn was modelled and the area from where the yarn is passing was
included to the numerical analysis.
Abstract: The sensitivity of orifice plate metering to disturbed
flow (either asymmetric or swirling) is a subject of great concern to
flow meter users and manufacturers. The distortions caused by pipe
fittings and pipe installations upstream of the orifice plate are major
sources of this type of non-standard flows. These distortions can alter
the accuracy of metering to an unacceptable degree. In this work, a
multi-scale object known as metal foam has been used to generate a
predetermined turbulent flow upstream of the orifice plate. The
experimental results showed that the combination of an orifice plate
and metal foam flow conditioner is broadly insensitive to upstream
disturbances. This metal foam demonstrated a good performance in
terms of removing swirl and producing a repeatable flow profile
within a short distance downstream of the device. The results of using
a combination of a metal foam flow conditioner and orifice plate for
non-standard flow conditions including swirling flow and asymmetric
flow show this package can preserve the accuracy of metering up to
the level required in the standards.
Abstract: A study of electromagnetic flow meter is presented in the paper. Comparison has been made between the analytical and the numerical results by the use of FEM numerical analysis (Quick Field 5.6) for determining polarization voltage through the circle cross section of the polarization transducer. Exciting and geometrical parameters increasing its effectiveness has been examined. The aim is to obtain maximal output signal. The investigations include different variants of the magnetic flux density distribution around the tube: homogeneous field of magnitude Bm, linear distribution with maximal value Bm and trapezium distribution conserving the same exciting magnetic energy as the homogeneous field.
Abstract: The new semi-experimental method for simulation of
the turbine flow meters rotation in the transitional flow has been
developed. The method is based on the experimentally established
exponential low of changing of dimensionless relative turbine gas
meter rotation frequency and meter inertia time constant. For
experimental evaluation of the meter time constant special facility
has been developed. The facility ensures instant switching of turbine
meter under test from one channel to the other channel with different
flow rate and measuring the meter response. The developed method
can be used for evaluation and predication of the turbine meters
response and dynamic error in the transitional flow with any arbitrary
law of flow rate changing. The examples of the method application
are presented.