Abstract: This paper is concerning the issues of behaviour of
lightweight expanded clay aggregates concrete exposed to high
temperature. Lightweight aggregates from expanded clay are
produced by firing of row material up to temperature 1050°C.
Lightweight aggregates have suitable properties in terms of volume
stability, when exposed to temperatures up to 1050°C, which could
indicate their suitability for construction applications with higher risk
of fire. The test samples were exposed to heat by using the standard
temperature-time curve ISO 834. Negative changes in resulting
mechanical properties, such as compressive strength, tensile strength,
and flexural strength were evaluated. Also visual evaluation of the
specimen was performed. On specimen exposed to excessive heat, an
explosive spalling could be observed, due to evaporation of
considerable amount of unbounded water from the inner structure of
the concrete.
Abstract: This paper attempts to evaluate the effect of fire
damage on concrete by using nonlinear resonance vibration method,
one of the nonlinear nondestructive method. Concrete exhibits not
only nonlinear stress-strain relation but also hysteresis and discrete
memory effect which are contained in consolidated materials.
Hysteretic materials typically show the linear resonance frequency
shift. Also, the shift of resonance frequency is changed according to
the degree of micro damage. The degree of the shift can be obtained
through nonlinear resonance vibration method. Five exposure
scenarios were considered in order to make different internal micro
damage. Also, the effect of post-fire-curing on fire-damaged concrete
was taken into account to conform the change in internal damage.
Hysteretic nonlinearity parameter was obtained by amplitudedependent
resonance frequency shift after specific curing periods. In
addition, splitting tensile strength was measured on each sample to
characterize the variation of residual strength. Then, a correlation
between the hysteretic nonlinearity parameter and residual strength
was proposed from each test result.
Abstract: Disasters are quite experienced in our days. They are
caused by floods, landslides, and building fires that is the main
objective of this study. To cope with these unexpected events,
precautions must be taken to protect human lives. The emphasis on
disposal work focuses on the resolution of the evacuation problem in
case of no-notice disaster. The problem of evacuation is listed as a
dynamic network flow problem. Particularly, we model the
evacuation problem as an earliest arrival flow problem with load
dependent transit time. This problem is classified as NP-Hard. Our
challenge here is to propose a metaheuristic solution for solving the
evacuation problem. We define our objective as the maximization of
evacuees during earliest periods of a time horizon T. The objective
provides the evacuation of persons as soon as possible. We
performed an experimental study on emergency evacuation from the
tunisian children’s hospital. This work prompts us to look for
evacuation plans corresponding to several situations where the
network dynamically changes.
Abstract: Strontium hexaferrite (SrFe12O19; Sr-ferrite) is one of
the well-known materials for permanent magnets. In this study, Mtype
strontium ferrite was prepared by following the conventional
ceramic method from steelmaking by-product. Initial materials;
SrCO3 and by-product, were mixed together in the composition of
SrFe12O19 in different Sr/Fe ratios. The mixtures of these raw
materials were dry-milled for 6h. The blended powder was presintered
(i.e. calcination) at 1000°C for different times periods, then
cooled down to room temperature. These pre-sintered samples were
re-milled in a dry atmosphere for 1h and then fired at different
temperatures in atmospheric conditions, and cooled down to room
temperature. The produced magnetic powder has a dense hexagonal
grain shape structure. The calculated energy product values for the
produced samples ranged from 0.3 to 2.4 MGOe.
Abstract: The objectives of the research are to study patterns of fire location distribution and develop techniques of Geographic Information System application in fire risk assessment for fire planning and management. Fire risk assessment was based on two factors: the vulnerability factor such as building material types, building height, building density and capacity for mitigation factor such as accessibility by road, distance to fire station, distance to hydrants and it was obtained from four groups of stakeholders including firemen, city planners, local government officers and local residents. Factors obtained from all stakeholders were converted into Raster data of GIS and then were superimposed on the data in order to prepare fire risk map of the area showing level of fire risk ranging from high to low. The level of fire risk was obtained from weighted mean of each factor based on the stakeholders. Weighted mean for each factor was obtained by Analytical Hierarchy Analysis.
Abstract: This study analyzes the crisis management and image repair strategies during the crisis of Mahidol Wittayanusorn School (MWIT) library burning. The library of this school was burned by a 16-year-old-male student on June 6th, 2010. This student blamed the school that the lesson was difficult, and other students were selfish. Although no one was in the building during the fire, it had caused damage to the building, books and electronic supplies around 130 million bahts (4.4 million USD). This event aroused many discourses arguing about the education system and morality. The strategies which were used during crisis were denial, shift the blame, bolstering, minimization, and uncertainty reduction. The results of using these strategies appeared after the crisis. That was the numbers of new students, who registered for the examination to get into this school in the later years, have remained the same.
Abstract: The adsorption efficiency of various adsorbents for the removal of Zn(II) ions from the waste printing developer was studied in laboratory batch mode. The maximum adsorption efficiency of 94.1% was achieved with unfired clay pellets size (d ≈ 15 mm). The obtained values of adsorption efficiency was subjected to the independent-samples t test in order to investigate the statistically significant differences of the investigated adsorbents for the effective removal of Zn(II) ions from the waste printing developer. The most statistically significant differences of adsorption efficiencies for Zn(II) ions removal were obtained between unfired clay pellets (size d ≈ 15 mm) and activated carbon (½t½=6.909), natural zeolite (½t½=10.380), mixture of activated carbon and natural zeolite (½t½=9.865), bentonite (½t½=6.159), fired clay (½t½=6.641), fired clay pellets (size d ≈ 5 mm) (½t½=6.678), fired clay pellets (size d ≈ 8 mm) (½t½=3.422), respectively.
Abstract: By running transactions under the SNAPSHOT isolation
we can achieve a good level of concurrency, specially in databases
with high-intensive read workloads. However, SNAPSHOT is not
immune to all the problems that arise from competing transactions
and therefore no serialization warranty exists. We propose in this
paper a technique to obtain data consistency with SNAPSHOT by using
some special triggers that we named DAEMON TRIGGERS. Besides
keeping the benefits of the SNAPSHOT isolation, the technique is
specially useful for those database systems that do not have an
isolation level that ensures serializability, like Firebird and Oracle. We
describe all the anomalies that might arise when using the SNAPSHOT
isolation and show how to preclude them with DAEMON TRIGGERS.
Based on the methodology presented here, it is also proposed the
creation of a new isolation level: DAEMON SNAPSHOT.
Abstract: Stoneware clay, fired clay (as a grog), calcite waste and class C fly ash in various mixing rations were the basic raw materials for the mixture for production of dry pressed ceramic tiles. Mechanical properties (water absorption, bulk density, apparent porosity, flexural strength) as well as mineralogical composition were studied on samples with different source of calcium oxide after firing at 900, 1000, 1100 and 1200°C. It was found that samples with addition of calcite waste contain dmisteinbergit and anorthite. This minerals help to improve the strength of the body and reduce porosity fired at lower temperatures. Class C fly ash has not significantly influence on properties of the fired body as calcite waste.
Abstract: Cross-laminated timber is increasingly being used in
the construction of high-rise buildings due to its simple
manufacturing system. In term of fire resistance, cross-laminated
timber panels are promoted as having excellent fire resistance,
comparable to that of non-combustible materials and to heavy
timber construction, due to the ability of thick wood assemblies to
char slowly at a predictable rate while maintaining most of their
strength during the fire exposure. This paper presents an overview of
fire performance of cross-laminated timber and evaluation of its
resistance to elevated temperature in comparison to homogeneous
timber panels. Charring rates for cross-laminated timber panels of
those obtained experimentally were compared with those provided by
Eurocode simplified calculation methods.
Abstract: The lignite-fired power plants in the Western Macedonia Lignite Center produce more than 8106 t of fly ash per year. Approximately 90% of this quantity is used for restoration-reclamation of exhausted open-cast lignite mines and slope stabilization of the overburden. The purpose of this work is to evaluate the environmental behavior of the mixture of waste rock and fly ash that is being used in the external deposition site of the South Field lignite mine. For this reason, a borehole was made within the site and 86 samples were taken and subjected to chemical analyses and leaching tests. The results showed very limited leaching of trace elements and heavy metals from this mixture. Moreover, when compared to the limit values set for waste acceptable in inert waste landfills, only few excesses were observed, indicating only minor risk for groundwater pollution. However, due to the complexity of both the leaching process and the contaminant pathway, more boreholes and analyses should be made in nearby locations and a systematic groundwater monitoring program should be implemented both downstream and within the external deposition site.
Abstract: Homemade HPC clusters are widely used in many small labs, because they are easy to build and cost-effective. Even though incremental growth is an advantage of clusters, it results in heterogeneous systems anyhow. Instead of adding new nodes to the cluster, we can extend clusters to include some other Internet servers working independently on the same LAN, so that we can make use of their idle times, especially during the night. However extension across a firewall raises some security problems with NFS. In this paper, we propose a method to solve such a problem using SSH tunneling, and suggest a modified structure of the cluster that implements it.
Abstract: A mathematical heat transfer model for the prediction of transient heating of the slab in a direct-fired walking beam type reheating furnace has been developed by considering the nongray thermal radiation with given furnace environments. The furnace is modeled as radiating nongray medium with carbon dioxide and water with five-zoned gas temperature and the furnace wall is considered as a constant temperature lower than furnace gas one. The slabs are moving with constant velocity depending on the residence time through the non-firing, charging, preheating, heating, and final soaking zones. Radiative heat flux obtained by considering the radiative heat exchange inside the furnace as well as convective one from the surrounding hot gases are introduced as boundary condition of the transient heat conduction within the slab. After validating thermal radiation model adopted in this work, thermal fields in both model and real reheating furnace are investigated in terms of radiative heat flux in the furnace and temperature inside the slab. The results show that the slab in the furnace can be more heated with higher slab emissivity and residence time.
Abstract: The contribution of the infill walls to the overall earthquake response of a structure is limited and this contribution is generally ignored in the analyses. Strengthening of the infill walls through different techniques has been and is being studied extensively in the literature to increase this limited contribution and the ductilities and energy absorption capacities of the infill walls to create non-structural components where the earthquake-induced energy can be absorbed without damaging the bearing components of the structural frame. The present paper summarizes an extensive research project dedicated to investigate the effects of strengthening the brick infill walls of a reinforced concrete (RC) frame on its lateral earthquake response. Perforated steel plates were used in strengthening due to several reasons, including the ductility and high deformation capacity of these plates, the fire resistant, recyclable and non-cancerogenic nature of mild steel, and the ease of installation and removal of the plates to the wall with the help of anchor bolts only. Furthermore, epoxy, which increases the cost and amount of labor of the strengthening process, is not needed in this technique. The individual behavior of the strengthened walls under monotonic diagonal and lateral reversed cyclic loading was investigated within the scope of the study. Upon achieving brilliant results, RC frames with strengthened infill walls were tested and are being tested to examine the influence of this strengthening technique on the overall behavior of the RC frames. Tests on the wall and frame specimens indicated that the perforated steel plates contribute to the lateral strength, rigidity, ductility and energy absorption capacity of the wall and the infilled frame to a major extent.
Abstract: Transient plane source method has been used to
measure the thermal diffusivity and thermal conductivity of a compact
isostatic electroceramics at room temperature. The samples were fired
at temperatures from 100 up to 1320 degrees Celsius in steps of
50. Bulk density and specific heat capacity were also measured with
their corresponding standard uncertainties. The results were compared
with further thermal analysis (dilatometry and thermogravimetry).
Structural processes during firing were discussed.
Abstract: The objective of this work is to use the Fire Dynamics Simulator (FDS) to investigate the behavior of a kerosene small-scale fire. FDS is a Computational Fluid Dynamics (CFD) tool developed specifically for fire applications. Throughout its development, FDS is used for the resolution of practical problems in fire protection engineering. At the same time FDS is used to study fundamental fire dynamics and combustion. Predictions are based on Large Eddy Simulation (LES) with a Smagorinsky turbulence model. LES directly computes the large-scale eddies and the sub-grid scale dissipative processes are modeled. This technique is the default turbulence model which was used in this study. The validation of the numerical prediction is done using a direct comparison of combustion output variables to experimental measurements. Effect of the mesh size on the temperature evolutions is investigated and optimum grid size is suggested. Effect of width openings is investigated. Temperature distribution and species flow are presented for different operating conditions. The effect of the composition of the used fuel on atmospheric pollution is also a focus point within this work. Good predictions are obtained where the size of the computational cells within the fire compartment is less than 1/10th of the characteristic fire diameter.
Abstract: Recently, distributed generation technologies have received much attention for the potential energy savings and reliability assurances that might be achieved as a result of their widespread adoption. The distribution feeder reconfiguration (DFR) is one of the most important control schemes in the distribution networks, which can be affected by DGs. This paper presents a new approach to DFR at the distribution networks considering wind turbines. The main objective of the DFR is to minimize the deviation of the bus voltage. Since the DFR is a nonlinear optimization problem, we apply the Adaptive Modified Firefly Optimization (AMFO) approach to solve it. As a result of the conflicting behavior of the single- objective function, a fuzzy based clustering technique is employed to reach the set of optimal solutions called Pareto solutions. The approach is tested on the IEEE 32-bus standard test system.
Abstract: Storage tank farms are essential industrial facilities to accumulate oil, petrochemicals and gaseous products. Since tank farms contain huge mass of fuel and hazardous materials, they are always targets of serious accidents such as fire, explosion, spill and toxic release which may cause severe impacts on human health, environmental and properties.
Although having a safe layout is not able to prevent initiating accidents, however it effectively controls and reduces the adverse impact of such accidents.
The aim of this paper is to determine the optimal layout for a storage tank contains different type of hydrocarbon fuels. A quantitative risk assessment is carried out on a selected tank farm in Jaipur, India, with particular attention given to both the consequence modeling and the overall risk assessment using PHAST Software. Various designs of tank layouts are examined taking into consideration several issues of plant operations and maintenance. In all stages of the work, standard guidelines specified by the industry are considered and recommendations are substantiated with simulation results and risk quantification.
Abstract: This study investigated the improvement in concrete properties with addition of cellulose, steel, carbon and PET fibers. Each fiber was added at four percentages to the fresh concrete, which was moist-cured for 28-days and then tested for compressive, flexural and tensile strengths. Changes in strength and increases in cost were analyzed. Results showed that addition of cellulose caused a decrease between 9.8% and 16.4% in compressive strength. This range may be acceptable as cellulose fibers can significantly increase the concrete resistance to fire, and freezing and thawing cycles. Addition of steel fibers to concreteincreased the compressive strength by up to 20%. Increases 121.5% and 80.7% were reported in tensile and flexural strengths respectively. Carbon fibers increased flexural and tensile strengths by up to 11% and 45%, respectively. Concrete strength properties decreased after the addition of PET fibers. Results showed that improvement in strength after addition of steel and carbon fibers may justify the extra cost of fibers.
Abstract: Forest areas are particularly susceptible to fires, which are often manmade. One of the most fire affected forest regions in the world is the Mediterranean. Libya, in the Mediterranean region, has soils that are considered to be arid except in a small area called Aljabal Alakhdar (Green mountain), which is the geographic area covered by this study. Like other forests in the Mediterranean it has suffered extreme degradation. This is mainly due to people removing fire wood, or sometimes converting forested areas to agricultural use, as well as fires which may alter several soil chemical and physical properties. The purpose of this study was to evaluate the effects of fires on the physical properties of soil of Aljabal Alakhdar forest in the north-east of Libya. The physical properties of soil following fire in two geographic areas have been determined, with those subjected to the fire compared to those in adjacent unburned areas in one coastal and one mountain site. Physical properties studied were: soil particle size (soil texture), soil water content, soil porosity and soil particle density. For the first time in Libyan soils, the effect of burning on the magnetic susceptibility properties of soils was also tested. The results showed that the soils in both study sites, irrespective of burning or depth fell into the category of a silt loam texture, low water content, homogeneity of porosity of the soil profiles, relatively high soil particle density values and there is a much greater value of the soil magnetic susceptibility in the top layer from both sites except for the soil water content and magnetic susceptibility, fire has not had a clear effect on the soils’ physical properties.