Proportion and Particle Size Distribution of Fine Aggregates Extracted From the Drained Binder in a Binder Drainage Test

Binder drainage test is widely used to set an upper limit to the design binder content of porous asphalt. However, the presence of high amount of fine particles in the drained binder may affect the accuracy of the test result. This paper presents a study to characterize the composition and particle size distribution of fine particles accumulated in the drained binder. Fine aggregates and filler in the drained binder were extracted using a suitable solvent. Then, wet and dry sieve analysis was carried out to identify the actual composition of the extracted fine aggregates and filler. From the results, almost half of the drained binder consisted of fine aggregates and this significantly affects the accuracy of the design binder content of porous asphalt mix. This simple finding highlights the importance of taking into account the presence of fine aggregates in the calculation of drained binder.