Abstract: Cesium iodide (CsI) melt was injected into anodic aluminum oxide (AAO) template and was solidified to CsI column. The controllable AAO channel size (10~500 nm) can makes CsI column size from 10 to 500 nm in diameter. In order to have a shorter light irradiate from each singe CsI column top to bottom the AAO template was coated a TiO2 nano-film. The TiO2 film acts a refraction film and makes X-ray has a shorter irradiation path in the CsI crystal making a stronger the photo-electron signal. When the incidence light irradiate from air (R=1.0) to CsI’s first surface (R=1.84) the first refraction happen, the first refraction continue into TiO2 film (R=2.88) and produces the low angle of the second refraction. Then the second refraction continue into AAO wall (R=1.78) and produces the third refraction after refractions between CsI and AAO wall (R=1.78) produce the fourth refraction. The incidence light through TiO2 filmand the first surface of CsI then arrive to the second surface of CsI. Therefore, the TiO2 film can has shorter refraction path of incidence light and increase the photo-electron conversion efficiency.
Abstract: The paper aims at investigating influence of medium
capacity on linear adsorbed solute dispersion into chemically
heterogeneous fixed beds. A discrete chemical heterogeneity
distribution is considered in the one-dimensional advectivedispersive
equation. The partial differential equation is solved using
finite volumes method based on the Adam-Bashforth algorithm.
Increased dispersion is estimated by comparing breakthrough curves
second order moments and keeping identical hydrodynamic
properties. As a result, dispersion increase due to chemical
heterogeneity depends on the column size and surprisingly on the
solid capacity. The more intense capacity is, the more important
solute dispersion is. Medium length which is known to favour this
effect vanishing according to the linear adsorption in fixed bed seems
to create nonmonotonous variation of dispersion because of the
heterogeneity. This nonmonotonous behaviour is also favoured by
high capacities.
Abstract: A method to predict the column size for displacement based design of reinforced concrete frame buildings with higher target inter storey drift is reported here. The column depth derived from empirical relation as a function of given beam section, target inter-story drift, building plan features and common displacement based design parameters is used. Regarding the high drift requirement, a minimum column-beam moment capacity ratio is maintained during capacity design. The method is used in designing four, eight and twelve story frame buildings with displacement based design for three percent target inter storey drift. Non linear time history analysis of the designed buildings are performed under five artificial ground motions to show that the columns are found elastic enough to avoid column sway mechanism assuring that for the design the column size can be used with or without minor changes.