Abstract: Hybrid photovoltaic thermal (PVT) collectors allow simultaneous production of electrical energy thus heat energy. There are several configurations of hybrid collectors (to produce water or air). For hybrids water collectors, there are several configurations that differ by the nature of the absorber (serpentine, tubes...). In this paper, an absorber tank is studied. The circulation of the coolant is natural (we do not use the pump). We present the obtained results in our experimental study and we analyzed the data, and then we compare the results with the theory practices. The electrical performances of the hybrid collector are compared with those of conventional photovoltaic module mounted on the same structure and measured under the same conditions.
We conducted experiments with natural circulation of the coolant (Thermosyphon), for a flow rate of 0.025kg/m².
Abstract: The paper represents the dependence of ammonia concentration on microclimate parameters and photocopying shop circulation. The concentration of ammonia was determined during 8-hours working time over five days including three sampling points of a photocopying shop in Novi Sad, Serbia. The obtained results pointed out that the room temperature possesses the highest impact on ammonia release. The obtained ammonia concentration was in the range of 1.53 to 0.42ppm and decreased with the temperature decreasing from 24.6 to 20.7oC. As the detected concentrations were within the permissible levels of The Occupational Safety and Health Administration, The National Institute for Occupational Safety and The Health and Official Gazette of Republic of Serbia, in the range of 35 to 200ppm, there was no danger to the employee’s health in the photocopying shop.
Abstract: Numerical study of heat transfer and fluid flow over vertical double forward facing step were presented. The k-w model with finite volume method was employed to solve continuity, momentum, and energy equations. Different step heights were adopted for range of Reynolds number varied from 10000 to 40000, and range of temperature varied from 310K to 340 K. The straight side of duct is insulated while the side of double forward facing step is heated. The result shows augmentation of heat transfer due to the recirculation region created after and before steps. Effect of step length and Reynolds number observed on increase of local Nusselt number particularly at recirculation regions. Contour of streamline velocity is plotted to show recirculation regions after and before steps. Numerical simulation in this paper done by used ANSYS FLUENT 14.
Abstract: Heat transfer and laminar fluid flow over backward facing step with and without obstacle numerically studied in this paper. The finite volume method adopted to solve continuity, momentum and energy equations in two dimensions. Backward facing step without obstacle and with different dimension of obstacle were presented. The step height and expansion ratio of channel were 4.8mm and 2 respectively, the range of Reynolds number varied from 75 to 225, constant heat flux subjected on downstream of wall was 2000W/m2, and length of obstacle was 1.5, 3, and 4.5mm with width 1.5mm. The separation length noticed increase with increase Reynolds number and height of obstacle. The result shows increase of heat transfer coefficient for backward facing step with obstacle in compared to those without obstacle. The maximum enhancement of heat transfer observed at 4.5mm of height obstacle due to increase recirculation flow after the obstacle in addition that at backward. Streamline of velocity showing the increase of recirculation region with used obstacle in compared without obstacle and highest recirculation region observed at obstacle height 4.5mm. The amount of enhancement heat transfer was varied between 3-5% compared to backward without obstacle.
Abstract: Cavitation is one of the most well-known process faults that may occur in different industrial equipment especially centrifugal pumps. Cavitation also may happen in water pumps and turbines. Sometimes cavitation has been severe enough to wear holes in the impeller and damage the vanes to such a degree that the impeller becomes very ineffective. More commonly, the pump efficiency will decrease significantly during cavitation and continue to decrease as damage to the impeller increases. Typically, when cavitation occurs, an audible sound similar to ‘marbles’ or ‘crackling’ is reported to be emitted from the pump. In this paper, the most effective monitoring items and techniques in detecting cavitation discussed in details. Besides, some successful solutions for solving this problem for sea water vertical Centrifugal lift Pump discussed through a case history related to Iran oil industry. Furthermore, balance line modification, strainer choking and random resonance in sea water pumps discussed. In addition, a new Method for diagnosing mechanical conditions of sea water vertical Centrifugal lift Pumps introduced. This method involves disaggregating bus current by device into disaggregated currents having correspondences with operating currents in response to measured bus current. Moreover, some new patents and innovations in mechanical sea water pumping and cooling systems discussed in this paper.
Abstract: The speed profiles, gas holdup (eG) and global oxygen transfer coefficient (kLa) from a stirred airlift bioreactor using water as the fluid model, was investigated by computational fluid dynamics modeling. The parameters predicted by the computer model were validated with the experimental dates. The CFD results were very close to those obtained experimentally. During the simulation it was verified a prevalent impeller effect at low speeds, propelling a large volume of fluid against the walls of the vessel, which without recirculation, results in low values of eG and kLa; however, by increasing air velocity, the impeller effect is smaller with the air flow being greater, in the region of the riser, causing fluid recirculation, which explains the increase in eG and kLa.
Abstract: As the ecology of Lake Shihwa has been restored significantly nowadays, the urban development is in progress around Lake Shihwa areas. Each development project includes a plan on utilizing waterfront areas, but there exist a difference on waterfront design criteria between experts and users. Therefore, it is significant to analyze preferences in design elements of existing waterfront parks around Lake Shihwa (Ansan Waterfront Park, Shihwa Reed Wetland Park, and T-Light Park) based on users’ perspectives and to reflect the result on upcoming waterfront developments. This study derives design elements on waterfront parks from literature reviews. The survey questionnaires are created based on these classified elements and the surveys are conducted to experts and users with in-depth interviews. For all three parks, several park facilities appear to be not recognized by users. Therefore the circulation path should be introduced in guide maps and information activities and furthermore in disposition of park facilities.
Abstract: Microcirculatory dysfunction is very common in sepsis and may results in organ failure and increased risk of death. Analyzing oxygen utilization can potentially assess microcirculation function of an individual. In this study, a modified pulse oximeter is used to extract information signals due to absorption of red (R) and infrared (IR) light. IR and R signal are related to the overall blood volume and reduced hemoglobin, respectively. Differences between these two signals thus represent the amount of oxygenated hemoglobin. Avascular occlusion test has been conducted on healthy individuals to validate the pulse oximeter concept. In this test, both R and IR signals rapidly changed according to the occlusion process. The pulse oximeter concept presented is capable of extracting valuable information to assess microcirculation condition. Implementing this concept on ICU patients has the potential to aid sepsis diagnosis and provide more accurate tracking of patient state and sepsis status.
Abstract: The characteristics of physiological blood flow in human carotid arterial bifurcation model have been numerically studied using a fully coupled fluid-structure interaction (FSI) analysis. This computational model with the fluid-structure interaction is constructed to investigate the flow characteristics and wall shear stress in the carotid artery. As the flow begins to decelerate after the peak flow, a large recirculation zone develops at the non-divider wall of both internal carotid artery (ICA) and external carotid artery (ECA) in FSI model due to the elastic energy stored in the expanding compliant wall. The calculated difference in wall shear stress (WSS) in both Non-FSI and FSI models is a range of between 5 and 11% at the mean WSS. The low WSS corresponds to regions of carotid artery that are more susceptible to atherosclerosis.
Abstract: An experimental study of the turbulent near wake of a rotating circular cylinder was made at a Reynolds number of 2000 for velocity ratios, λ between 0 and 2.7. Particle image velocimetry data are analyzed to study the effects of rotation on the flow structures behind the cylinder. The results indicate that the rotation of the cylinder causes significant changes in the vortex formation. Kármán vortex shedding pattern of alternating vortices gives rise to strong periodic fluctuations of a vortex street for λ < 2.0. Alternate vortex shedding is weak and close to being suppressed at λ = 2.0 resulting a distorted street with vortices of alternating sense subsequently being found on opposite sides. Only part of the circulation is shed due to the interference in the separation point, mixing in the base region, re-attachment, and vortex cut-off phenomenon. Alternating vortex shedding pattern diminishes and completely disappears when the velocity ratio is 2.7. The shed vortices are insignificant in size and forming a single line of vortex street. It is clear that flow asymmetries will deteriorate vortex shedding, and when the asymmetries are large enough, total inhibition of a periodic street occurs.
Abstract: Haemodialysis (HD) is a procedure saving patient lives around the world, unfortunately it brings numerous complications. Oxidative stress is one of the major factors which lead to erythrocytes destruction during extracorporeal circulation. Repeated HD procedures destroy blood elements and the organism is not able to keep up with their production. 30 HD procedures on healthy sheep were performed to evaluate effects of such treatment. Oxidative stress study was performed together with an analysis of basic blood parameters and empirical assessment of dialyzer condition after the procedure. A reversible decline in absolute leukocyte count, during first 30 min of HD, was observed. Blood clots were formed in the area of the blood inlet and outlet of the dialyzer. Our results are consistent with outcomes presented throughout the literature specifically with respect to the effects observed in humans and will provide a basis to evaluate methods for blood protection during haemodialysis.
Abstract: Heat transfer and laminar air flow over a double backward-facing step numerically studied in this paper. The simulations was performed by using ANSYS ICEM for meshing process and using ANSYS fluent 14 (CFD) for solving. The k-ɛ standard model adopted with Reynolds number varied between 98.5 to 512 and three step height at constant heat flux (q=2000 W/m2). The top of wall and bottom of upstream are insulated with bottom of downstream is heated. The results show increase in Nusselt number with increases of Reynolds number for all cases and the maximum of Nusselt number happens at the first step in compared to the second step. Due to increase of cross section area of downstream to generate sudden expansion then Nusselt number decrease but the profile of Nusselt number keep same trend for all cases where increase after the first and second steps. Recirculation region after the first and second steps are denoted by contour of streamline velocity. The higher augmentation of heat transfer rate observed for case 1 at Reynolds number of 512 and heat flux q=2000 W/m2.
Abstract: The central recirculation zone (CRZ) in a swirl
stabilized gas turbine combustor has a dominant effect on the fuel air
mixing process and flame stability. Most of state of the art swirlers
share one disadvantage; the fixed swirl number for the same swirler
configuration. Thus, in a mathematical sense, Reynolds number
becomes the sole parameter for controlling the flow characteristics
inside the combustor. As a result, at low load operation, the
generated swirl is more likely to become feeble affecting the flame
stabilization and mixing process. This paper introduces a new swirler
concept which overcomes the mentioned weakness of the modern
configurations. The new swirler introduces air tangentially and
axially to the combustor through tangential vanes and an axial vanes
respectively. Therefore, it provides different swirl numbers for the
same configuration by regulating the ratio between the axial and
tangential flow momenta. The swirler aerodynamic performance was
investigated using four CFD simulations in order to demonstrate the
impact of tangential to axial flow rate ratio on the CRZ. It was found
that the length of the CRZ is directly proportional to the tangential to
axial air flow rate ratio.
Abstract: This work presents a theoretical investigation of the
simultaneous absorption of CO2 and H2S into aqueous solutions of
MDEA and DEA. In this process the acid components react
with the basic alkanolamine solution via an exothermic,
reversible reaction in a gas/liquid absorber. The use of amine
solvents for gas sweetening has been investigated using
process simulation programs called HYSYS and ASPEN. We
use Electrolyte NRTL and Amine Package and Amines
(experimental) equation of state. The effects of temperature and
circulation rate and amine concentration and packed column and
murphree efficiency on the rate of absorption were studied.
When lean amine flow and concentration increase, CO2 and H2S
absorption increase too. With the improvement of inlet amine
temperature in absorber, CO2 and H2S penetrate to upper stages of
absorber and absorption of acid gases in absorber decreases. The CO2
concentration in the clean gas can be greatly influenced by the
packing height, whereas for the H2S concentration in the clean gas the
packing height plays a minor role. HYSYS software can not
estimate murphree efficiency correctly and it applies the same
contributions in all diagrams for HYSYS software. By
improvement in murphree efficiency, maximum temperature
of absorber decrease and the location of reaction transfer to the
stages of bottoms absorber and the absorption of acid gases
increase.
Abstract: This paper presents a cold flow simulation study of a small gas turbine combustor performed using laboratory scale test rig. The main objective of this investigation is to obtain physical insight of the main vortex, responsible for the efficient mixing of fuel and air. Such models are necessary for predictions and optimization of real gas turbine combustors. Air swirler can control the combustor performance by assisting in the fuel-air mixing process and by producing recirculation region which can act as flame holders and influences residence time. Thus, proper selection of a swirler is needed to enhance combustor performance and to reduce NOx emissions. Three different axial air swirlers were used based on their vane angles i.e., 30°, 45°, and 60°. Three-dimensional, viscous, turbulent, isothermal flow characteristics of the combustor model operating at room temperature were simulated via Reynolds- Averaged Navier-Stokes (RANS) code. The model geometry has been created using solid model, and the meshing has been done using GAMBIT preprocessing package. Finally, the solution and analysis were carried out in a FLUENT solver. This serves to demonstrate the capability of the code for design and analysis of real combustor. The effects of swirlers and mass flow rate were examined. Details of the complex flow structure such as vortices and recirculation zones were obtained by the simulation model. The computational model predicts a major recirculation zone in the central region immediately downstream of the fuel nozzle and a second recirculation zone in the upstream corner of the combustion chamber. It is also shown that swirler angles changes have significant effects on the combustor flowfield as well as pressure losses.
Abstract: This paper presents the prediction of air flow,
humidity and temperature patterns in a co-current pilot plant spray
dryer fitted with a pressure nozzle using a three dimensional model.
The modelling was done with a Computational Fluid Dynamic
package (Fluent 6.3), in which the gas phase is modelled as
continuum using the Euler approach and the droplet/ particle phase is
modelled by the Discrete Phase model (Lagrange approach).Good
agreement was obtained with published experimental data where the
CFD simulation correctly predicts a fast downward central flowing
core and slow recirculation zones near the walls. In this work, the
effects of the air flow pattern on droplets trajectories, residence time
distribution of droplets and deposition of the droplets on the wall also
were investigated where atomizing of maltodextrin solution was
used.
Abstract: Freeze concentration freezes or crystallises the water
molecules out as ice crystals and leaves behind a highly concentrated
solution. In conventional suspension freeze concentration where ice
crystals formed as a suspension in the mother liquor, separation of
ice is difficult. The size of the ice crystals is still very limited which
will require usage of scraped surface heat exchangers, which is very
expensive and accounted for approximately 30% of the capital cost.
This research is conducted using a newer method of freeze
concentration, which is progressive freeze concentration. Ice crystals
were formed as a layer on the designed heat exchanger surface. In
this particular research, a helical structured copper crystallisation
chamber was designed and fabricated. The effect of two operating
conditions on the performance of the newly designed crystallisation
chamber was investigated, which are circulation flowrate and coolant
temperature. The performance of the design was evaluated by the
effective partition constant, K, calculated from the volume and
concentration of the solid and liquid phase. The system was also
monitored by a data acquisition tool in order to see the temperature
profile throughout the process. On completing the experimental
work, it was found that higher flowrate resulted in a lower K, which
translated into high efficiency. The efficiency is the highest at 1000
ml/min. It was also found that the process gives the highest
efficiency at a coolant temperature of -6 °C.
Abstract: Laser Doppler flowmetry is a modern method of noninvasive
microcirculation investigation. The aim of our study was to
use this method in the examination of patients with secondary
lymphedema of the lower extremities and obliterating atherosclerosis
of lower extremities. In the analysis of the amplitude-frequency
spectrum of secondary lymphedema patients we have identified
remarkable changes. To describe the changes we used a special
amplitude rate. In both of patients groups this rate was significally
(p
Abstract: Both prognostic and diagnostic modes of a 3D baroclinic
model in hydrodynamic and sediment transport models of
the Princeton Ocean Model (POM) were conducted to separate
prognose and diagnose effects of different hydrodynamic factors on
transport of suspended sediment discharged from the rivers to the
Gulf of Thailand (GoT). Both transport modes of suspended sediment
distribution in the GoT were numerically simulated. It could be
concluded that the suspended sediment discharged from the rivers
around the GoT. Most of sediments in estuaries and coastal areas are
deposited outside the GoT under the condition of wind-driven current,
and very small amount of the sediments of them are transported
faraway. On the basis of wind forcing, sediments from the lower
GoT to the upper GoT are mainly transported south-northwestward
and also continuously moved north-southwestward. An obvious 3D
characteristic of suspended sediment transport is produced in the
wind-driven current residual circulation condition. In this study, the
transport patterns at the third layer are generally consistent with
the typhoon-induced strong currents in two case studies of Typhoon
Linda 1997. The case studies presented the prognostic and diagnostic
modes during 00UTC28OCT1997 to 12UTC06NOV1997 in a short
period with the current condition for pre-operation of the suspended
sediment transport model in estuaries and coastal areas.
Abstract: Now-a-days, numbers of simulation software are
being used all over the world to solve Computational Fluid
Dynamics (CFD) related problems. In this present study, a
commercial CFD simulation software namely STAR-CCM+ is
applied to analyze the airflow characteristics inside a 2.5" hard
disk drive. Each step of the software is described adequately to
obtain the output and the data are verified with the theories to
justify the robustness of the simulation outcome. This study
gives an insight about the accuracy level of the CFD
simulation software to compute CFD related problems
although it largely depends upon the computer speed. Also
this study will open avenues for further research.