Abstract: This research aimed to develop plasma system used in air conditioners. This developed plasma system could be installed in the air conditioners - all split type. The quality of air could be improved to be equal to present plasma system. Development processes were as follows: 1) to study the plasma system used in the air conditioners, 2) to design a plasma generator, 3) to develop the plasma generator, and 4) to test its performance in many types of the air conditioners. This plasma system was developed by AC high voltage – 14 kv with a frequency of 50 kHz. Carbon was a conductor to generate arc in air purifier system. The research was tested by installing the plasma generator in the air conditioners - wall type. Whereas, there were 3 types of installations: air flow out, air flow in, and room center. The result of the plasma generator installed in the air conditioners, split type, revealed that the air flow out installation provided the highest average of o-zone at 223 mg/h. This type of installation provided the highest efficiency of air quality improvement. Moreover, the air flow in installation and the room center installation provided the average of the o-zone at 163 mg/h and 64 mg/h, respectively.
Abstract: The work presented in this study is related to an
energy system analysis based on passive cooling system for
dwellings. It consists to solar chimney energy performances
determination versus geometrical and environmental considerations
as the size and inlet width conditions of the chimney. Adrar site
located in the southern region of Algeria is chosen for this study
according to ambient temperature and solar irradiance technical data
availability. Obtained results are related to the glazing temperature
distributions, the chimney air flow and internal wall temperatures.
The air room change per hour (ACH) parameter, the outlet air
velocity and mass air flow rate are also determined. It is shown that
the chimney width has a significant effect on energy performances
compared to its entry size. A good agreement is observed between
these results and those obtained by others from the literature.
Abstract: This paper presents a numerical study on surface heat
transfer characteristics of laminar air flows in parallel-plate dimpled
channels. The two-dimensional numerical model is provided by
commercial code FLUENT and the results are obtained for channels
with symmetrically opposing hemi-cylindrical cavities onto both
walls for Reynolds number ranging from 1000 to 2500. The influence
of variations in relative depth of dimples (the ratio of cavity depth to
the cavity curvature diameter), the number of them and the thermophysical
properties of channel walls on heat transfer enhancement is
studied. The results are evident for existence of an optimum value for
the relative depth of dimples in which the largest wall heat flux and
average Nusselt number can be achieved. In addition, the results of
conjugation simulation indicate that the overall influence of the ratio
of wall thermal conductivity to the one of the fluid on heat transfer
rate is not much significant and can be ignored.
Abstract: Applying corona wind as a novel technique can lead
to a great level of heat and mass transfer augmentation by using very
small amount of energy. Enhancement of forced flow evaporation
rate by applying electric field (corona wind) has been experimentally
evaluated in this study. Corona wind produced by a fine wire
electrode which is charged with positive high DC voltage impinges
to water surface and leads to evaporation enhancement by disturbing
the saturated air layer over water surface. The study was focused on
the effect of corona wind velocity, electrode spacing and air flow
velocity on the level of evaporation enhancement. Two sets of
experiments, i.e. with and without electric field, have been
conducted. Data obtained from the first experiment were used as
reference for evaluation of evaporation enhancement at the presence
of electric field. Applied voltages ranged from corona threshold
voltage to spark over voltage at 1 kV increments. The results showed
that corona wind has great enhancement effect on water evaporation
rate, but its effectiveness gradually diminishes by increasing air flow
velocity. Maximum enhancements were 7.3 and 3.6 for air velocities
of 0.125 and 1.75 m/s, respectively.
Abstract: There have been widespread applications of fluidized beds in industries which are related to the combination of gas-solid particles during the last decade. For instance, in order to crack the catalyses in petrochemical industries or as a drier in food industries. High capacity of fluidized bed in heat and mass transfer has made this device very popular. In order to achieve a higher efficiency of fluidized beds, a particular attention has been paid to beds with pulsating air flow. In this paper, a fluidized bed device with pulsating flow has been designed and constructed. Size of particles have been used during the test are in the range of 40 to 100μm. The purpose of this experimental test is to investigate the air flow regime, observe the particles- movement and measure the pressure loss along the bed. The effects of pulsation can be evaluated by comparing the results for both continuous and pulsating flow. Results of both situations are compared for various gas speeds. Moreover the above experiment is numerically simulated by using Fluent software and its numerical results are compared with the experimental results.
Abstract: The present paper was concerned primarily with the
analysis, simulation of the air flow and thermal patterns in a lecture
room. The paper is devoted to numerically investigate the influence
of location and number of ventilation and air conditioning supply and
extracts openings on air flow properties in a lecture room. The work
focuses on air flow patterns, thermal behaviour in lecture room where
large number of students. The effectiveness of an air flow system is
commonly assessed by the successful removal of sensible and latent
loads from occupants with additional of attaining air pollutant at a
prescribed level to attain the human thermal comfort conditions and
to improve the indoor air quality; this is the main target during the
present paper. The study is carried out using computational fluid
dynamics (CFD) simulation techniques as embedded in the
commercially available CFD code (FLUENT 6.2). The CFD
modelling techniques solved the continuity, momentum and energy
conservation equations in addition to standard k – ε model equations
for turbulence closure.
Throughout the investigations, numerical validation is carried out by
way of comparisons of numerical and experimental results. Good
agreement is found among both predictions.
Abstract: This paper addresses one important aspect of
combustion system analysis, the spray evaporation and
dispersion modeling. In this study we assume an empty
cylinder which is as a simulator for a ramjet engine and the
cylinder has been studied by cold flow. Four nozzles have the
duties of injection which are located in the entrance of
cylinder. The air flow comes into the cylinder from one side
and injection operation will be done. By changing injection
velocity and entrance air flow velocity, we have studied
droplet sizing and efficient mass fraction of fuel vapor near
and at the exit area. We named the mass of fuel vapor inside
the flammability limit as the efficient mass fraction. Further,
we decreased the initial temperature of fuel droplets and we
have repeated the investigating again. To fulfill the calculation
we used a modified version of KIVA-3V.
Abstract: Natural ventilation is an important means to improve indoor thermal comfort and reduce the energy consumption. A solar chimney system is an enhancing natural draft device, which uses solar radiation to heat the air inside the chimney, thereby converting the thermal energy into kinetic energy. The present study considered some parameters such as chimney width and solar intensity, which were believed to have a significant effect on space ventilation. Fluent CFD software was used to predict buoyant air flow and flow rates in the cavities. The results were compared with available published experimental and theoretical data from the literature. There was an acceptable trend match between the present results and the published data for the room air change per hour, ACH. Further, it was noticed that the solar intensity has a more significant effect on ACH.
Abstract: In an effort to understand the preliminary effects of aerodynamic stress on alveolar epithelial cells, we developed a multifluidic cell culture platform capable of supporting alveolar cultures at an air-liquid interface under constant air flow and exposure to varying pressure stimuli on the apical side while providing nourishment on the basolateral plane. Our current study involved utilizing the platform to study the effect of basement membrane coating and addition of dexamethasone on cellular response to pressure in A549 and H441 alveolar epithelial cells.
Abstract: Understanding of how and where NOx formation
occurs in industrial burner is very important for efficient and clean
operation of utility burners. Also the importance of this problem is
mainly due to its relation to the pollutants produced by more burners
used widely of gas turbine in thermal power plants and glass and steel
industry.
In this article, a numerical model of an industrial burner operating
in MILD combustion is validated with experimental data.. Then
influence of air flow rate and air temperature on combustor
temperature profiles and NOX product are investigated. In order to
modification this study reports on the effects of fuel and air dilution
(with inert gases H2O, CO2, N2), and also influence of lean-premixed
of fuel, on the temperature profiles and NOX emission.
Conservation equations of mass, momentum and energy, and
transport equations of species concentrations, turbulence, combustion
and radiation modeling in addition to NO modeling equations were
solved together to present temperature and NO distribution inside the
burner.
The results shows that dilution, cause to a reduction in value of
temperature and NOX emission, and suppresses any flame
propagation inside the furnace and made the flame inside the furnace
invisible. Dilution with H2O rather than N2 and CO2 decreases further
the value of the NOX. Also with raise of lean-premix level, local
temperature of burner and the value of NOX product are decreases
because of premixing prevents local “hot spots" within the combustor
volume that can lead to significant NOx formation. Also leanpremixing
of fuel with air cause to amount of air in reaction zone is
reach more than amount that supplied as is actually needed to burn
the fuel and this act lead to limiting NOx formation
Abstract: This study deals with Computational Fluid Dynamics
(CFD) studies of the interactions between the air flow and louvered
fins which equipped the automotive heat exchangers. 3D numerical
simulation results are obtained by using the ANSYS Fluent 13.0 code
and compared to experimental data. The paper studies the effect of
louver angle and louver pitch geometrical parameters, on overall
thermal hydraulic performances of louvered fins.
The comparison between CFD simulations and experimental data
show that established 3-D CFD model gives a good agreement. The
validation agrees, with about 7% of deviation respectively of friction
and Colburn factors to experimental results. As first, it is found that
the louver angle has a strong influence on the heat transfer rate. Then,
louver angle and louver pitch variation of the louvers and their effects
on thermal hydraulic performances are studied. In addition to this
study, it is shown that the second half of the fin takes has a
significant contribution on pressure drop increase without any
increase in heat transfer.
Abstract: The nonlinear damping behavior is usually ignored in
the design of a miniature moving-coil loudspeaker. But when the
loudspeaker operated in air, the damping parameter varies with the
voice-coil displacement corresponding due to viscous air flow. The
present paper presents an identification model as inverse problem to
identify the nonlinear damping parameter in the lumped parameter
model for the loudspeaker. Theoretical results for the nonlinear
damping are verified by using laser displacement measurement
scanner. These results indicate that the damping parameter has the
greatly different nonlinearity between in air and vacuum. It is believed
that the results of the present work can be applied in diagnosis and
sound quality improvement of a miniature loudspeaker.
Abstract: The objective of this study is to investigate fire
behaviors, experimentally and numerically, in a scaled version of an
underground station. The effect of ventilation velocity on the fire is
examined. Fire experiments are simulated by burning 10 ml
isopropyl alcohol fuel in a fire pool with dimensions 5cm x 10cm x 4
mm at the center of 1/100 scaled underground station model. A
commercial CFD program FLUENT was used in numerical
simulations. For air flow simulations, k-ω SST turbulence model and
for combustion simulation, non-premixed combustion model are
used. This study showed that, the ventilation velocity is increased
from 1 m/s to 3 m/s the maximum temperature in the station is found
to be less for ventilation velocity of 1 m/s. The reason for these
experimental result lies on the relative dominance of oxygen supply
effect on cooling effect. Without piston effect, maximum temperature
occurs above the fuel pool. However, when the ventilation velocity
increased the flame was tilted in the direction of ventilation and the
location of maximum temperature moves along the flow direction.
The velocities measured experimentally in the station at different
locations are well matched by the CFD simulation results. The
prediction of general flow pattern is satisfactory with the smoke
visualization tests. The backlayering in velocity is well predicted by
CFD simulation. However, all over the station, the CFD simulations
predicted higher temperatures compared to experimental
measurements.
Abstract: The combustion of liquid fuel in the porous burner
(PB) was experimented to investigate evaporation mechanism and
combustion behavior. The diesel oil was used as fuel and the pebbles
carefully chosen in the same size like the solid sphere homogeneously
was adopted as the porous media. Two structures of the liquid porous
burner, i.e. the PB without and with installation of porous emitter
(PE), were performed. PE was installed by lower than PB with
distance of 20 cm. The pebbles having porosity (φ) of 0.45 and 0.52
were, respectively, used in PB and PE. The fuel was supplied dropwise
from the top through the PB and the combustion was occurred between
PB and PE. Axial profiles of temperature along the burner length were
measured to clarify the evaporation and combustion phenomena. The
pollutant emission characteristics were monitored at the burner exit.
From the experiment, it was found that the temperature profiles of both
structures decreased with the three ways swirling air flows (QA)
increasing. On the other hand, the temperature profiles increased with
fuel heat input (QF). Obviously, the profile of the porous burner
installed with PE was higher than that of the porous burner without
PE
Abstract: Water recycling represents an important challenge for many countries, in particular in countries where this natural resource is rare. On the other hand, in many operations, water is used as a cooling medium, as a high proportion of water consumed in industry is used for cooling purposes. Generally this water is rejected directly to the nature. This reject will cause serious environment damages as well as an important waste of this precious element.. On way to solve these problems is to reuse and recycle this warm water, through the use of natural cooling medium, such as air in a heat exchanger unit, known as a cooling tower. A poor performance, design or reliability of cooling towers will result in lower flow rate of cooling water an increase in the evaporation of water, an hence losses of water and energy. This paper which presents an experimental investigate of thermal and hydraulic performances of a mechanical cooling tower, enables to show that the water evaporation rate, Mev, increases with an increase in the air and water flow rates, as well as inlet water temperature and for fixed air flow rates, the pressure drop (ΔPw/Z) increases with increasing , L, due to the hydrodynamic behavior of the air/water flow.
Abstract: In research on natural ventilation, and passive cooling
with forced convection, is essential to know how heat flows in a solid
object and the pattern of temperature distribution on their surfaces,
and eventually how air flows through and convects heat from the
surfaces of steel under roof. This paper presents some results from
running the computational fluid dynamic program (CFD) by
comparison between natural ventilation and forced convection within
roof attic that is received directly from solar radiation. The CFD
program for modeling air flow inside roof attic has been modified to
allow as two cases. First case, the analysis under natural ventilation,
is closed area in roof attic and second case, the analysis under forced
convection, is opened area in roof attic. These extend of all cases to
available predictions of variations such as temperature, pressure, and
mass flow rate distributions in each case within roof attic. The
comparison shows that this CFD program is an effective model for
predicting air flow of temperature and heat transfer coefficient
distribution within roof attic. The result shows that forced convection
can help to reduce heat transfer through roof attic and an around area
of steel core has temperature inner zone lower than natural
ventilation type. The different temperature on the steel core of roof
attic of two cases was 10-15 oK.
Abstract: The fluid mechanics principle is used extensively in
designing axial flow fans and their associated equipment. This paper presents a computational fluid dynamics (CFD) modeling of air flow
distribution from a radiator axial flow fan used in an acid pump truck Tier4 (APT T4) Repower. This axial flow fan augments the transfer
of heat from the engine mounted on the APT T4.
CFD analysis was performed for an area weighted average static pressure difference at the inlet and outlet of the fan. Pressure contours, velocity vectors, and path lines were plotted for detailing
the flow characteristics for different orientations of the fan blade. The results were then compared and verified against known theoretical observations and actual experimental data. This study
shows that a CFD simulation can be very useful for predicting and understanding the flow distribution from a radiator fan for further
research work.
Abstract: This paper addresses one important aspect of
combustion system analysis, the spray evaporation and
dispersion modeling. In this study we assume an empty
cylinder which is as a simulator for a ramjet engine and the
cylinder has been studied by cold flow. Four nozzles have the
duties of injection which are located in the entrance of
cylinder. The air flow comes into the cylinder from one side
and injection operation will be done. By changing injection
velocity and entrance air flow velocity, we have studied
droplet sizing and efficient mass fraction of fuel vapor near
and at the exit area. We named the mass of fuel vapor inside
the flammability limit as the efficient mass fraction. Further,
we decreased the initial temperature of fuel droplets and we
have repeated the investigating again. To fulfill the calculation
we used a modified version of KIVA-3V.
Abstract: The major part of light weight timber constructions
consists of insulation. Mineral wool is the most commonly used
insulation due to its cost efficiency and easy handling. The fiber
orientation and porosity of this insulation material enables flowthrough.
The air flow resistance is low. If leakage occurs in the
insulated bay section, the convective flow may cause energy losses
and infiltration of the exterior wall with moisture and particles. In
particular the infiltrated moisture may lead to thermal bridges and
growth of health endangering mould and mildew. In order to prevent
this problem, different numerical calculation models have been
developed. All models developed so far have a potential for
completion. The implementation of the flow-through properties of
mineral wool insulation may help to improve the existing models.
Assuming that the real pressure difference between interior and
exterior surface is larger than the prescribed pressure difference in the
standard test procedure for mineral wool ISO 9053 / EN 29053,
measurements were performed using the measurement setup for
research on convective moisture transfer “MSRCMT".
These measurements show, that structural inhomogeneities of
mineral wool effect the permeability only at higher pressure
differences, as applied in MSRCMT. Additional microscopic
investigations show, that the location of a leak within the
construction has a crucial influence on the air flow-through and the
infiltration rate. The results clearly indicate that the empirical values
for the acoustic resistance of mineral wool should not be used for the
calculation of convective transfer mechanisms.
Abstract: The presented article deals with the description of a
numerical model of a corridor at a Central Interim Spent Fuel Storage
Facility (hereinafter CISFSF). The model takes into account the
effect of air flows on the temperature of stored waste. The
computational model was implemented in the ANSYS/CFX
programming environment in the form of a CFD task solution, which
was compared with an approximate analytical calculation. The article
includes a categorization of the individual alternatives for the
ventilation of such underground systems. The aim was to evaluate a
ventilation system for a CISFSF with regard to its stability and
capacity to provide sufficient ventilation for the removal of heat
produced by stored casks with spent nuclear fuel.