Abstract: Segmenting the lungs in medical images is a
challenging and important task for many applications. In particular,
automatic segmentation of lung cavities from multiple magnetic
resonance (MR) images is very useful for oncological applications
such as radiotherapy treatment planning. However, distinguishing of
the lung areas is not trivial due to largely changing lung shapes, low
contrast and poorly defined boundaries. In this paper, we address
lung segmentation problem from pulmonary magnetic resonance
images and propose an automated method based on a robust regionaided
geometric snake with a modified diffused region force into the
standard geometric model definition. The extra region force gives the
snake a global complementary view of the lung boundary
information within the image which along with the local gradient
flow, helps detect fuzzy boundaries. The proposed method has been
successful in segmenting the lungs in every slice of 30 magnetic
resonance images with 80 consecutive slices in each image. We
present results by comparing our automatic method to manually
segmented lung cavities provided by an expert radiologist and with
those of previous works, showing encouraging results and high
robustness of our approach.
Abstract: A mammography image is composed of low contrast area where the breast tissues and the breast abnormalities such as microcalcification can hardly be differentiated by the medical practitioner. This paper presents the application of active contour models (Snakes) for the segmentation of microcalcification in mammography images. Comparison on the microcalcifiation areas segmented by the Balloon Snake, Gradient Vector Flow (GVF) Snake, and Distance Snake is done against the true value of the microcalcification area. The true area value is the average microcalcification area in the original mammography image traced by the expert radiologists. From fifty images tested, the result obtained shows that the accuracy of the Balloon Snake, GVF Snake, and Distance Snake in segmenting boundaries of microcalcification are 96.01%, 95.74%, and 95.70% accuracy respectively. This implies that the Balloon Snake is a better segmentation method to locate the exact boundary of a microcalcification region.
Abstract: This paper is concerned with an improved algorithm
based on the piecewise-smooth Mumford and Shah (MS) functional
for an efficient and reliable segmentation. In order to speed up
convergence, an additional force, at each time step, is introduced
further to drive the evolution of the curves instead of only driven by
the extensions of the complementary functions u + and u - . In our
scheme, furthermore, the piecewise-constant MS functional is
integrated to generate the extra force based on a temporary image that
is dynamically created by computing the union of u + and u - during
segmenting. Therefore, some drawbacks of the original algorithm,
such as smaller objects generated by noise and local minimal problem
also are eliminated or improved. The resulting algorithm has been
implemented in Matlab and Visual Cµ, and demonstrated efficiently
by several cases.
Abstract: Deformable active contours are widely used in
computer vision and image processing applications for image
segmentation, especially in biomedical image analysis. The active
contour or “snake" deforms towards a target object by controlling the
internal, image and constraint forces. However, if the contour
initialized with a lesser number of control points, there is a high
probability of surpassing the sharp corners of the object during
deformation of the contour. In this paper, a new technique is
proposed to construct the initial contour by incorporating prior
knowledge of significant corners of the object detected using the
Harris operator. This new reconstructed contour begins to deform, by
attracting the snake towards the targeted object, without missing the
corners. Experimental results with several synthetic images show the
ability of the new technique to deal with sharp corners with a high
accuracy than traditional methods.