Abstract: The heat storage capacity of concrete in building shells is a major reason for excessively large electricity consumption induced by indoor air conditioning. In this research, the previously developed Smart Temperature Information Material (STIM) is embedded in two groups of exterior wall specimens (the control group contains reinforced concrete exterior walls and the experimental group consists of tiled exterior walls). Long term temperature measurements within the concrete are taken by the embedded STIM. Temperature differences between the control group and the experimental group in walls facing the four cardinal directions (east, west, south, and north) are evaluated. This study aims to provide a basic reference for the design of exterior walls and the selection of heat insulation materials.
Abstract: Passive systems were born with the purpose of the
greatest exploitation of solar energy in cold climates and high
altitudes. They spread themselves until the 80-s all over the world
without any attention to the specific climate and the summer
behavior; this caused the deactivation of the systems due to a series
of problems connected to the summer overheating, the complex
management and the rising of the dust.
Until today the European regulation limits only the winter
consumptions without any attention to the summer behavior but, the
recent European EN 15251 underlines the relevance of the indoor
comfort, and the necessity of the analytic studies validation by
monitoring case studies.
In the porpose paper we demonstrate that the solar wall is an
efficient system both from thermal comfort and energy saving point
of view and it is the most suitable for our temperate climates because
it can be used as a passive cooling sistem too. In particular the paper
present an experimental and numerical analisys carried out on a case
study with nine different solar passive systems in Ancona, Italy.
We carried out a detailed study of the lodging provided by the
solar wall by the monitoring and the evaluation of the indoor
conditions.
Analyzing the monitored data, on the base of recognized models
of comfort (ISO, ASHRAE, Givoni-s BBCC), is emerged that the
solar wall has an optimal behavior in the middle seasons. In winter
phase this passive system gives more advantages in terms of energy
consumptions than the other systems, because it gives greater heat
gain and therefore smaller consumptions. In summer, when outside
air temperature return in the mean seasonal value, the indoor comfort
is optimal thanks to an efficient transversal ventilation activated from
the same wall.
Abstract: Thermal load calculations have been performed for
multi-layered walls that are composed of three different parts; a
common (sand and cement) plaster, and two types of locally
produced soft and hard bricks. The masonry construction of these
layered walls was based on concrete-backed stone masonry made of
limestone bricks joined by mortar. These multilayered walls are
forming the outer walls of the building envelope of a typical Libyan
house. Based on the periodic seasonal weather conditions, within the
Libyan cost region during summer and winter, measured thermal
conductivity values were used to implement such seasonal variation
of heat flow and the temperature variations through the walls. The
experimental measured thermal conductivity values were obtained
using the Hot Disk technique. The estimation of the thermal
resistance of the wall layers ( R-values) is based on measurements
and calculations. The numerical calculations were done using a
simplified analytical model that considers two different wall
constructions which are characteristics of such houses. According to
the obtained results, the R-values were quite low and therefore,
several suggestions have been proposed to improve the thermal
loading performance that will lead to a reasonable human comfort
and reduce energy consumption.