Abstract: In this paper proposed the effective fault detection of industrial drives by using Biorthogonal Posterior Vibration Signal-Data Probabilistic Wavelet Neural Network (BPPVS-WNN) system. This system was focused to reducing the current flow and to identify faults with lesser execution time with harmonic values obtained through fifth derivative. Initially, the construction of Biorthogonal vibration signal-data based wavelet transform in BPPVS-WNN system localizes the time and frequency domain. The Biorthogonal wavelet approximates the broken bearing using double scaling and factor, identifies the transient disturbance due to fault on induction motor through approximate coefficients and detailed coefficient. Posterior Probabilistic Neural Network detects the final level of faults using the detailed coefficient till fifth derivative and the results obtained through it at a faster rate at constant frequency signal on the industrial drive. Experiment through the Simulink tool detects the healthy and unhealthy motor on measuring parametric factors such as fault detection rate based on time, current flow rate, and execution time.
Abstract: Fixed bed adsorption has become a frequently used
industrial application in wastewater treatment processes. Various low
cost adsorbents have been studied for their applicability in treatment
of different types of effluents. In this work, the intention of the study
was to explore the efficacy and feasibility for azo dye, Acid Orange 7
(AO7) adsorption onto fixed bed column of NaOH Treated eggshell
(TES). The effect of various parameters like flow rate, initial dye
concentration, and bed height were exploited in this study. The
studies confirmed that the breakthrough curves were dependent on
flow rate, initial dye concentration solution of AO7 and bed depth.
The Thomas, Yoon–Nelson, and Adams and Bohart models were
analysed to evaluate the column adsorption performance. The
adsorption capacity, rate constant and correlation coefficient
associated to each model for column adsorption was calculated and
mentioned. The column experimental data were fitted well with
Thomas model with coefficients of correlation R2 ≥0.93 at different
conditions but the Yoon–Nelson, BDST and Bohart–Adams model
(R2=0.911), predicted poor performance of fixed-bed column. The
(TES) was shown to be suitable adsorbent for adsorption of AO7
using fixed-bed adsorption column.
Abstract: The present study investigated the protective effect of
thymoquinone (TQ), against cadmium-induced kidney injury in rats.
Cadmium chloride (1.2 mg Cd/kg/day, s.c.), was given for nine
weeks. TQ treatment (40 mg/kg/day, p.o.) started on the same day of
cadmium administration and continued for nine weeks. TQ
significantly decreased serum creatinine, renal malondialdehyde and
nitric oxide, and significantly increased renal reduced glutathione in
rats received cadmium. Histopathological examination showed that
TQ markedly minimized renal tissue damage induced by cadmium.
Immunohistochemical analysis revealed that TQ markedly decreased
the cadmium-induced expression of inducible nitric oxide synthase,
tumor necrosis factor-α, cyclooxygenase-2, and caspase-3 in renal
tissue. It was concluded that TQ significantly protected against
cadmium nephrotoxicity in rats, through its antioxidant, antiinflammatory,
and antiapoptotic actions.
Abstract: This study investigated the differences in the objective parameters of sound depending on the changes in the lengths of the lateral surfaces of a space and on the replacement of the sound absorbers that are placed on these surfaces. To this end, three models of room were chosen. The widths and heights of these rooms were the same but the lengths of the rooms were changed. The smallest room was 8 m. wide and 10 m. long. The lengths of the other two rooms were 15 m. and 20 m. For each model, the differences in the objective parameters of sound were determined by keeping all the material in the space intact and by changing only the positions of the sound absorbers that were placed on the walls. The sound absorbers that were used on the walls were of two different sizes. The sound absorbers that were placed on the walls were 4 m and 8 m. long and story-height (3 m.). In all model room types, the sound absorbers were placed on the long walls in three different ways: at the end of the long walls where the long walls meet the front wall; at the end of the long walls where the long walls meet the back wall; and in the middle part of the long walls. Except for the specially placed sound absorbers, the ground, wall and ceiling surfaces were covered with three different materials. There were no constructional elements such as doors and windows on the walls. On the surfaces, the materials specified in the Odeon 10 material library were used as coating material. Linoleum was used as flooring material, painted plaster as wall coating material and gypsum boards as ceiling covering (2 layers with a total of 32 mm. thickness). These were preferred due to the fact that they are the commonly used materials for these purposes. This study investigated the differences in the objective parameters of sound depending on the changes in the lengths of the lateral surfaces of a space and on the replacement of the sound absorbers that are placed on these surfaces. To this end, three models of room were chosen. The widths and heights of these rooms were the same but the lengths of the rooms were changed. The smallest room was 8 m. wide and 10 m. long. The lengths of the other two rooms were 15 m. and 20 m. For each model, the differences in the objective parameters of sound were determined by keeping all the material in the space intact and by changing only the positions of the sound absorbers that were placed on the walls. The sound absorbers that were used on the walls were of two different sizes. The sound absorbers that were placed on the walls were 4 m and 8 m. long and story-height (3 m.). In all model room types, the sound absorbers were placed on the long walls in three different ways: at the end of the long walls where the long walls meet the front wall; at the end of the long walls where the long walls meet the back wall; and in the middle part of the long walls. Except for the specially placed sound absorbers, the ground, wall and ceiling surfaces were covered with three different materials. There were no constructional elements such as doors and windows on the walls. On the surfaces, the materials specified in the Odeon 10 material library were used as coating material. Linoleum was used as flooring material, painted plaster as wall coating material and gypsum boards as ceiling covering (2 layers with a total of 32 mm. thickness). These were preferred due to the fact that they are the commonly used materials for these purposes.
Abstract: This case study used the action research concept as a tool to integrate the innovation in a learning experience on a design course. The action research was investigated at Prince Sultan University, College of Engineering in the Interior Design and Architecture Department in January 2015, through the Higher Education Academy program. The action research was presented first with the definition of the research, leading to how it was used and how solutions were found. It concluded by showing that once the action research application in interior design and architecture were studied it was an effective tool to improve student’s learning, develop their practice in design courses, and it discussed the negative and positive issues that were encountered.
Abstract: Introduction: This work is aimed to represent the use of the OPTI-JET CS MD1 MR prototype for application of neutral electrolyzed oxidizing water (NEOW) in magnetic resonance rooms. Material and Methods: We produced and used OPTI-JET CS MD1 MR aerosolisator whereby was performed aerosolization. The presence of microorganisms before and after the aerosolisation was recorded with the help of cyclone air sampling. Colony formed units (CFU) was counted. Results: The number of microorganisms in magnetic resonance 3T room was low as expected. Nevertheless, a possible CFU reduction of 87% was recorded. Conclusions: The research has shown that the use of EOW for the air and hard surface disinfection can considerably reduce the presence of microorganisms and consequently the possibility of hospital infections. It has also demonstrated that the use of OPTI-JET CS MD1 MR is very good. With this research, we started new guidelines for aerosolization in magnetic resonance rooms. Future work: We predict that presented technique works very good but we must focus also on time capacity sensors, and new appropriate toxicological studies.
Abstract: Promotion of the Fiber Reinforced Concrete (FRC) as a construction material for civil engineering projects has invoked numerous researchers to investigate their mechanical behavior. Even though there is satisfactory information about the effects of fiber type and length, concrete mixture, casting type and other variables on the strength and deformability parameters of FRC, the numerical modeling of such materials still needs research attention. The focus of this study is to investigate the feasibility of Concrete Damaged Plasticity (CDP) model in prediction of Macro-synthetic FRC structures behavior. CDP model requires the tensile behavior of concrete to be well characterized. For this purpose, a series of uniaxial direct tension and four point bending tests were conducted on the notched specimens to define bilinear tension softening (post-peak tension stress-strain) behavior. With these parameters obtained, the flexural behavior of macro-synthetic FRC beams were modeled and the results showed a good agreement with the experimental measurements.
Abstract: Recently, the world main problem is a global warming and climate change affecting both outdoor and indoor environments, especially the air quality (AQ) as a result of vast migration of people from rural areas to urban areas. Therefore, cities became more crowded and denser from an irregular population increase, along with increasing urbanization caused many problems for the environment such as increasing the land prices, changes in life style, and the new buildings are not adapted to the climate producing uncomfortable and unhealthy indoor building conditions. As interior environments are the places that create the most intimate relationship with the user. Consequently, the indoor environment quality (IEQ) for buildings became uncomfortable and unhealthy for its occupants. The symptoms commonly associated with poor indoor environment such as itchy, headache, fatigue, and respiratory complaints such as cough and congestion, etc. The symptoms tend to improve over time or even disappear when people are away from the building. Therefore, designing a healthy indoor environment to fulfill human needs is the main concern for architects and interior designer. However, this research explores how occupant expectations and environmental attitudes may influence occupant health and satisfaction within the context of the indoor environment. In doing so, it reviews and contributes to the methods and tools used to evaluate only the indoor environment quality (IEQ) components of building performance. Its main aim is to review the literature on indoor human comfort. This is followed by a review of previous papers published related to human comfort. Finally, this paper will provide possible approaches in design level of healthy buildings.
Abstract: Reinforced concrete (RC) shear wall system of residential buildings is popular in South Korea. RC walls are subjected to axial forces in common and the effect of axial forces on the strength loss of the fire damaged walls has not been investigated. This paper aims at investigating temperature distribution on fire damaged concrete walls having different axial loads. In the experiments, a variable of specimens is axial force ratio. RC walls are fabricated with 150mm of wall thicknesses, 750mm of lengths and 1,300mm of heights having concrete strength of 24MPa. After curing, specimens are heated on one surface with ISO-834 standard time-temperature curve for 2 hours and temperature distributions during the test are measured using thermocouples inside the walls. The experimental results show that the temperature of the RC walls exposed to fire increases as axial force ratio increases. To verify the experiments, finite element (FE) models are generated for coupled temperature-structure analyses. The analytical results of thermal behaviors are in good agreement with the experimental results. The predicted displacement of the walls decreases when the axial force increases.
Abstract: In subjective terms, Polish SME sector occupies a
prominent position in the national economic development, in which
planning of the management strategies should be primarily based on
identifying and meeting the innovation needs. As a research sample, there is chosen a printing sector of industry.
SMEs share in printing sector in Poland is estimated at the level of
81% of all enterprises. In recent years, the printing industry achieved
one of the highest levels of EU support in Poland. There is a
relatively high increase in the development of technological
innovations in equipment and the associated significant increase in
production capacity. It can be also noticed that on average, every
third enterprise belonging to the printing industry has implemented
innovations, but not all of them effected in better economic results.
Therefore, the aim of this article is to evaluate the impact of the
implementation of innovation projects financed from the EU funds
for performance of SMEs in the printing industry. As the results of research of EU funds co-financing effects on the
development of innovation in the printing industry, it was specified
that examined SMEs prefer to implement product innovation to
receive a grant to the project at a level between 40% to 60%, the
remaining part of the investment is usually covered with equity. The most common type of innovation had indicated a single
implementation, related only to the change in process, technology, or
organization. The relationship between variables of the EU funds and
management of innovative activities was verified. It has been
observed that the identified variables arising from the support in a
form of the EU funds had a positive effect on the level of earned
revenue, the increase in margin and in increase in employment as
well. It was confirmed that the implemented innovations supported
by the European funds have a positive impact on the performance of
the printing companies. Although there is a risk that due to the
decreasing demand for printing services such a high level of funding
the companies in this sector will significantly increase competition in
the long term, that may also contribute to the economic problems of
the enterprises belonging to the analyzed branch.
Abstract: Critical success factors (CSFs) and the criteria to measure project success have received much attention over the decades and are among the most widely researched topics in the context of project management. However, although there have been extensive studies on the subject by different researchers, to date, there has been little agreement on the CSFs. The aim of this study is to identify the CSFs that influence the performance of construction projects, and determine their relative importance for different objectives across five stages in the project life cycle. A considerable literature review was conducted that resulted in the identification of 179 individual factors. These factors were then grouped into nine major categories. A questionnaire survey was used to collect data from three groups of respondents: client representatives, consultants, and contractors. Out of 164 questionnaires distributed, 93 were returned, yielding a response rate of 56.7%. Using the mean score, relative importance index, and weighted average method, the top 10 critical factors for each category were identified. The agreement of survey respondents on those categorised factors were analysed using Spearman’s rank correlation. A one-way analysis of variance was then performed to determine whether the mean scores among the various groups of respondents were statistically significant. The findings indicate the most CSFs in each category in procurement phase are: proper procurement programming of materials (time), stability in the price of materials (cost), and determining quality in the construction (quality). They are then followed by safety equipment acquisition and maintenance (health and safety), budgeting allowed in a contractual arrangement for implementing environmental management activities (environment), completeness of drawing documents (productivity), accurate measurement and pricing of bill of quantities (risk management), adequate communication among the project team (human resource), and adequate cost control measures (client satisfaction). An understanding of CSFs would help all interested parties in the construction industry to improve project performance. Furthermore, the results of this study would help construction professionals and practitioners take proactive measures for effective project management.
Abstract: This work studies the effect of thickness on structural
and electrical properties of CuAlS2 thin films grown by two stage
vacuum thermal evaporation technique. CuAlS2 thin films of
thicknesses 50nm, 100nm and 200nm were deposited on suitably
cleaned corning 7059 glass substrate at room temperature (RT). In
the first stage Cu-Al precursors were grown at room temperature by
thermal evaporation and in the second stage Cu-Al precursors were
converted to CuAlS2 thin films by sulfurisation under sulfur
atmosphere at the temperature of 673K. The structural properties of
the films were examined by X-ray diffraction (XRD) technique while
electrical properties of the specimens were studied using four point
probe method. The XRD studies revealed that the films are of
crystalline in nature having tetragonal structure. The variations of the
micro-structural parameters, such as crystallite size (D), dislocation
density ( ), and micro-strain ( ), with film thickness were
investigated. The results showed that the crystallite sizes increase as
the thickness of the film increases. The dislocation density and
micro-strain decreases as the thickness increases. The resistivity ( )
of CuAlS2 film is found to decrease with increase in film thickness,
which is related to the increase of carrier concentration with film
thickness. Thus thicker films exhibit the lowest resistivity and high
carrier concentration, implying these are the most conductive films.
Low electrical resistivity and high carrier concentration are widely
used as the essential components in various optoelectronic devices
such as light-emitting diode and photovoltaic cells.
Abstract: In this paper, we present an analytical method for
analysis of nano-scale spherical shell subjected to thermo-mechanical
shocks based on nonlocal elasticity theory. Thermo-mechanical
properties of nano shpere is assumed to be temperature dependent.
Governing partial differential equation of motion is solved
analytically by using Laplace transform for time domain and power
series for spacial domain. The results in Laplace domain is
transferred to time domain by employing the fast inverse Laplace
transform (FLIT) method. Accuracy of present approach is assessed
by comparing the the numerical results with the results of published
work in literature. Furtheremore, the effects of non-local parameter
and wall thickness on the dynamic characteristics of the nano-sphere
are studied.
Abstract: Pipelines are extensively used engineering structures
which convey fluid from one place to another. Most of the time,
pipelines are placed underground and are encumbered by soil weight
and traffic loads. Corrosion of pipe material is the most common
form of pipeline deterioration and should be considered in both the
strength and serviceability analysis of pipes.
The study in this research focuses on concrete pipes in sewage
systems (concrete sewers). This research firstly investigates how to
involve the effect of corrosion as a time dependent process of
deterioration in the structural and failure analysis of this type of pipe.
Then three probabilistic time dependent reliability analysis methods
including the first passage probability theory, the gamma distributed
degradation model and the Monte Carlo simulation technique are
discussed and developed. Sensitivity analysis indexes which can be
used to identify the most important parameters that affect pipe failure
are also discussed.
The reliability analysis methods developed in this paper contribute
as rational tools for decision makers with regard to the strengthening
and rehabilitation of existing pipelines. The results can be used to
obtain a cost-effective strategy for the management of the sewer
system.
Abstract: Problem of food preservation is extremely important
for mankind. Viscous damage ("illness") of bread results from
development of Bacillus spp. bacteria. High temperature resistant
spores of this microorganism are steady against 120°C) and remain in
bread during pastries, potentially causing spoilage of the final
product. Scientists are interested in further characterization of bread
spoiling Bacillus spp. species. Our aim was to find weather yeast
Saccharomyces cerevisiae strains that are able to produce natural
antimicrobial killer factor can preserve bread illness. By diffusion
method, we showed yeast antagonistic activity against spore-forming
bacteria. Experimental technological parameters were the same as for
bakers' yeasts production on the industrial scale. Risograph test
during dough fermentation demonstrated gas production. The major
finding of the study was a clear indication of the presence of killer
yeast strain antagonistic activity against rope in bread causing
bacteria. After demonstrating antagonistic effect of S. cerevisiae on
bacteria using solid nutrient medium, we tested baked bread under
provocative conditions. We also measured formation of carbon
dioxide in the dough, dough-making duration and quality of the final
products, when using different strains of S. cerevisiae. It is
determined that the use of yeast S. cerevisiae RCAM 01730 killer
strain inhibits appearance of rope in bread. Thus, natural yeast
antimicrobial killer toxin, produced by some S. cerevisiae strains is
an anti-rope in bread protector.
Abstract: In this paper, a single phase soft switched Zero Voltage Transition and Zero Current Transition (ZVT-ZCT) Power Factor Correction (PFC) boost converter is proposed. In the proposed PFC converter, the main switch turns on with ZVT and turns off with ZCT without any additional voltage or current stresses. Auxiliary switch turns on and off with zero current switching (ZCS). Also, the main diode turns on with zero voltage switching (ZVS) and turns off with ZCS. The proposed converter has features like low cost, simple control and structure. The output current and voltage are controlled by the proposed PFC converter in wide line and load range. The theoretical analysis of converter is clarified and the operating steps are given in detail. The simulation results of converter are obtained for 500 W and 100 kHz. It is observed that the semiconductor devices operate with soft switching (SS) perfectly. So, the switching power losses are minimum. Also, the proposed converter has 0.99 power factor with sinusoidal current shape.
Abstract: Experiments were performed to investigate the effects of roughness on the reattachment and redevelopment regions over a 12 mm forward facing step (FFS) in an open channel flow. The experiments were performed over an upstream smooth wall and a smooth FFS, an upstream wall coated with sandpaper 36 grit and a smooth FFS and an upstream rough wall produced from sandpaper 36 grit and a FFS coated with sandpaper 36 grit. To investigate only the wall roughness effects, Reynolds number, Froude number, aspect ratio and blockage ratio were kept constant. Upstream profiles showed reduced streamwise mean velocities close to the rough wall compared to the smooth wall, but the turbulence level was increased by upstream wall roughness. The reattachment length for the smooth-smooth wall experiment was 1.78h; however, when it is replaced with rough-smooth wall the reattachment length decreased to 1.53h. It was observed that the upstream roughness increased the physical size of contours of maximum turbulence level; however, the downstream roughness decreased both the size and magnitude of contours in the vicinity of the leading edge of the step. Quadrant analysis was performed to investigate the dominant Reynolds shear stress contribution in the recirculation region. The Reynolds shear stress and turbulent kinetic energy profiles after the reattachment showed slower recovery compared to the streamwise mean velocity, however all the profiles fairly collapse on their corresponding upstream profiles at x/h = 60. It was concluded that to obtain a complete collapse several more streamwise distances would be required.
Abstract: The purpose of this study is to investigate the efficacy of solution-focused group therapy on improving the depressed mothers of child abuser families. This study was carried out in the form of a semi-pilot, pre-test and post-test on two groups (experimental and control). Subjects include all mothers and their children that are the members of Shush and Naser Khosro child home. Beck Depression Inventory and Child Trauma Questionnaire were used to collect data. First, child abuse questionnaire was completed by children, Then Beck Depression Inventory was completed by their mothers that 22 of them were recognized as depressed and randomly divided in two groups of experimental and control. After applying pre-test for both of these groups, the intervention of solution- focused group therapy was performed in five sessions on experimental group. Finally, post-test was applied on both groups and subsequently in a month, follow-up test was performed. T-test, multivariate variance, and repeated measurement analysis of variance were used to analyze the data. According to the findings, it can be concluded that this therapy leads to the improvement of depressed mother's mood. As a result, the intervention of solution-focused group therapy is useful in order to improve the depressing mood of mothers of child abuser families.
Abstract: Feedback is a vital element for improving student
learning in a simulation-based training as it guides and refines
learning through scaffolding. A number of studies in literature have
shown that students’ learning is enhanced when feedback is provided
with personalized tutoring that offers specific guidance and adapts
feedback to the learner in a one-to-one environment. Thus, emulating
these adaptive aspects of human tutoring in simulation provides an
effective methodology to train individuals. This paper presents the results of a study that investigated the
effectiveness of automating different types of feedback techniques
such as Knowledge-of-Correct-Response (KCR) and Answer-Until-
Correct (AUC) in software simulation for learning basic information
technology concepts. For the purpose of comparison, techniques like
simulation with zero or no-feedback (NFB) and traditional hands-on
(HON) learning environments are also examined. The paper presents the summary of findings based on quantitative
analyses which reveal that the simulation based instructional
strategies are at least as effective as hands-on teaching methodologies
for the purpose of learning of IT concepts. The paper also compares
the results of the study with the earlier studies and recommends
strategies for using feedback mechanism to improve students’
learning in designing and simulation-based IT training.
Abstract: We investigate the performance of an integrated cascade (IC) refrigeration system which uses environment friendly zeotropic mixtures. Computational calculation has been carried out by varying pressure level at the evaporator and the condenser of the system. Effects of mass flow rate of the refrigerant on the coefficient of performance (COP) are presented. We show that the integrated cascade system produces ultra-low temperatures in the evaporator by using environment friendly zeotropic mixture.