Abstract: In this paper by using the port-controlled Hamiltonian
(PCH) systems theory, a full-order nonlinear controlled model is first
developed. Then a nonlinear passivity-based robust adaptive control
(PBRAC) of switched reluctance motor in the presence of external
disturbances for the purpose of torque ripple reduction and
characteristic improvement is presented. The proposed controller
design is separated into the inner loop and the outer loop controller.
In the inner loop, passivity-based control is employed by using
energy shaping techniques to produce the proper switching function.
The outer loop control is employed by robust adaptive controller to
determine the appropriate Torque command. It can also overcome the
inherent nonlinear characteristics of the system and make the whole
system robust to uncertainties and bounded disturbances. A 4KW 8/6
SRM with experimental characteristics that takes magnetic saturation
into account is modeled, simulation results show that the proposed
scheme has good performance and practical application prospects.
Abstract: This study aims to investigate mechanical behavior of
deep-drawn cups consisting of aluminum (A1050)/ duralumin
(A2017) multi-layered clad structures with micro- and macro-scale
functional gradients. Such multi-layered clad structures are possibly
used for a new type of crash-boxes in automobiles to effectively
absorb the impact forces generated when automobiles having
collisions. The effect of heat treatments on microstructure,
compositional gradient, micro hardness in 2 and 6-layered aluminum/
duralumin clad structures, which were fabricated by hot rolling, have
been investigated. Impact compressive behavior of deep-drawn cups
consisting of such aluminum/ duralumin clad structures has been also
investigated in terms of energy absorption and maximum force.
Deep-drawn cups consisting of 6-layerd clad structures with microand
macro-scale functional gradients exhibit superior properties in
impact compressive tests.
Abstract: Importance of environmental efficiency of electric power industry stems from high demand for energy combined with global warming concerns. It is especially essential for the world largest economies like that of the United States. The paper introduces a Data Envelopment Analysis (DEA) model of environmental efficiency using indicators of fossil fuels utilization, emissions rate, and electric power losses. Using DEA is advantageous in this situation over other approaches due to its nonparametric nature. The paper analyzes data for the period of 1990 - 2006 by comparing actual yearly levels in each dimension with the best values of partial indicators for the period. As positive factors of efficiency, tendency to the decline in emissions rates starting 2000, and in electric power losses starting 2004 may be mentioned together with increasing trend of fuel utilization starting 1999. As a result, dynamics of environmental efficiency is positive starting 2002. The main concern is the decline in fossil fuels utilization in 2006. This negative change should be reversed to comply with ecological and economic requirements.
Abstract: Energy and exergy study of air-water combined solar collector which is called dual purpose solar collector (DPSC) is investigated. The method of ε - NTU is used. Analysis is performed for triangle channels. Parameters like the air flow rate and water inlet temperature are studied. Results are shown that DPSC has better energy and exergy efficiency than single collector. In addition, the triangle passage with water inlet temperature of 60O C has shown better exergy and energy efficiency.
Abstract: This article presents a performance comparison of an
interior mounted permanent magnet synchronous generator (IPMSG)
with a synchronous reluctance generator (SynRG) with the same size
for a wind application. It is found that using the same geometrical
dimensions, a SynRG can convert 74 % of the power that an IPMSG
can convert, while it has 80% of the IPMSG weight. Moreover it is
found that the efficieny for the IMPSG is 99% at rated power
compared to 98.7% for the SynRG.
Abstract: The aim of this study was to extract sugar from
sugarcane using high electric field pulse (HELP) as a non-thermal cell permeabilization method. The result of this study showed that it
is possible to permeablize sugar cane cells using HELP at very short times (less than 10 sec.) and at room temperature. Increasing the field strength (from 0.5kV/cm to 2kV/cm) and pulse number (1 to 12) led to increasing the permeabilization of sugar cane cells. The energy
consumption during HELP treatment of sugar cane (2.4 kJ/kg) was about 100 times less compared to thermal cell disintegration at 85
Abstract: This paper focuses on reducing the power consumption
of wireless sensor networks. Therefore, a communication protocol
named LEACH (Low-Energy Adaptive Clustering Hierarchy) is modified.
We extend LEACHs stochastic cluster-head selection algorithm
by a modifying the probability of each node to become cluster-head
based on its required energy to transmit to the sink. We present
an efficient energy aware routing algorithm for the wireless sensor
networks. Our contribution consists in rotation selection of clusterheads
considering the remoteness of the nodes to the sink, and then,
the network nodes residual energy. This choice allows a best distribution
of the transmission energy in the network. The cluster-heads
selection algorithm is completely decentralized. Simulation results
show that the energy is significantly reduced compared with the
previous clustering based routing algorithm for the sensor networks.
Abstract: Non-uniform current distribution in polymer
electrolyte membrane fuel cells results in local over-heating,
accelerated ageing, and lower power output than expected. This
issue is very critical when fuel cell experiences water flooding. In
this work, the performance of a PEM fuel cell is investigated under
cathode flooding conditions. Two-dimensional partially flooded
GDL models based on the conservation laws and electrochemical
relations are proposed to study local current density distributions
along flow fields over a wide range of cell operating conditions.
The model results show a direct association between cathode inlet
humidity increases and that of average current density but the
system becomes more sensitive to flooding. The anode inlet
relative humidity shows a similar effect. Operating the cell at
higher temperatures would lead to higher average current densities
and the chance of system being flooded is reduced. In addition,
higher cathode stoichiometries prevent system flooding but the
average current density remains almost constant. The higher anode
stoichiometry leads to higher average current density and higher
sensitivity to cathode flooding.
Abstract: Renewable energy resources are inexhaustible, clean as compared with conventional resources. Also, it is used to supply regions with no grid, no telephone lines, and often with difficult accessibility by common transport. Satellite earth stations which located in remote areas are the most important application of renewable energy. Neural control is a branch of the general field of intelligent control, which is based on the concept of artificial intelligence. This paper presents the mathematical modeling of satellite earth station power system which is required for simulating the system.Aswan is selected to be the site under consideration because it is a rich region with solar energy. The complete power system is simulated using MATLAB–SIMULINK.An artificial neural network (ANN) based model has been developed for the optimum operation of earth station power system. An ANN is trained using a back propagation with Levenberg–Marquardt algorithm. The best validation performance is obtained for minimum mean square error. The regression between the network output and the corresponding target is equal to 96% which means a high accuracy. Neural network controller architecture gives satisfactory results with small number of neurons, hence better in terms of memory and time are required for NNC implementation. The results indicate that the proposed control unit using ANN can be successfully used for controlling the satellite earth station power system.
Abstract: Alternative energy is any energy source that is an alternative to fossil fuel. These alternatives are intended to address concerns about such fossil fuels. Today, because of the variety of energy choices and differing goals of their advocates, defining some energy types as "alternative" is highly controversial. Most of the recent and existing alternative sources of energy are discussed below
Abstract: This paper was to study the clothes dryer using waste
heat from a split type air conditioner with a capacity of 12,648 btu/h.
The drying chamber had a minimum cross section area with the size
of 0.5 x 1.0 m2. The chamber was constructed by sailcloth and was
inside folded with aluminium foil. Then, it was connected to the
condensing unit of an air conditioner. The experiment was carried out
in two aspects which were the clothes drying with and without
auxiliary fan unit. The results showed that the drying rate of clothes
in the chamber installed with and without auxiliary fan unit were
2.26 and 1.1 kg/h, respectively. In case of the chamber installed with
a auxiliary fan unit, the additional power of 0.011 kWh was
consumed and the drying rate was higher than that of clothes drying
without auxiliary fan unit. Without auxiliary fan unit installation, no
energy was required but there was a portion of hot air leaks away
through the punctured holes at the wall of the drying chamber, hence
the drying rate was dropped below. The drying rate of clothes drying
using waste heat was higher than natural indoor drying and
commercial dryer which their drying rate were 0.17 and 1.9 kg/h,
respectively. It was noted that the COP of the air conditioner did not
change during the operating of clothes drying.
Abstract: Due to heavy energy constraints in WSNs clustering is
an efficient way to manage the energy in sensors. There are many
methods already proposed in the area of clustering and research is
still going on to make clustering more energy efficient. In our paper
we are proposing a minimum spanning tree based clustering using
divide and conquer approach. The MST based clustering was first
proposed in 1970’s for large databases. Here we are taking divide and
conquer approach and implementing it for wireless sensor networks
with the constraints attached to the sensor networks. This Divide and
conquer approach is implemented in a way that we don’t have to
construct the whole MST before clustering but we just find the edge
which will be the part of the MST to a corresponding graph and
divide the graph in clusters there itself if that edge from the graph can
be removed judging on certain constraints and hence saving lot of
computation.
Abstract: The purpose of this study is to investigate the chemical
degradation of the organophosphorus pesticide of parathion and
carbamate insecticide of methomyl in the aqueous phase through
Fenton process. With the employment of batch Fenton process, the
degradation of the two selected pesticides at different pH, initial
concentration, humic acid concentration, and Fenton reagent dosages
was explored. The Fenton process was found effective to degrade
parathion and methomyl. The optimal dosage of Fenton reagents (i.e.,
molar concentration ratio of H2O2 to Fe2+) at pH 7 for parathion
degradation was equal to 3, which resulted in 50% removal of
parathion. Similarly, the optimal dosage for methomyl degradation
was 1, resulting in 80% removal of methomyl. This study also found
that the presence of humic substances has enhanced pesticide
degradation by Fenton process significantly. The mass spectroscopy
results showed that the hydroxyl free radical may attack the single
bonds with least energy of investigated pesticides to form smaller
molecules which is more easily to degrade either through
physio-chemical or bilolgical processes.
Abstract: Let G be a graph of order n. The second stage adjacency matrix of G is the symmetric n × n matrix for which the ijth entry is 1 if the vertices vi and vj are of distance two; otherwise 0. The sum of the absolute values of this second stage adjacency matrix is called the second stage energy of G. In this paper we investigate a few properties and determine some upper bounds for the largest eigenvalue.
Abstract: A mobile ad hoc network is a network of mobile nodes
without any notion of centralized administration. In such a network,
each mobile node behaves not only as a host which runs applications
but also as a router to forward packets on behalf of others. Clustering
has been applied to routing protocols to achieve efficient
communications. A CH network expresses the connected relationship
among cluster-heads. This paper discusses the methods for
constructing a CH network, and produces the following results: (1)
The required running costs of 3 traditional methods for constructing a
CH network are not so different from each other in the static
circumstance, or in the dynamic circumstance. Their running costs in
the static circumstance do not differ from their costs in the dynamic
circumstance. Meanwhile, although the routing costs required for the
above 3 methods are not so different in the static circumstance, the
costs are considerably different from each other in the dynamic
circumstance. Their routing costs in the static circumstance are also
very different from their costs in the dynamic circumstance, and the
former is one tenths of the latter. The routing cost in the dynamic
circumstance is mostly the cost for re-routing. (2) On the strength of
the above results, we discuss new 2 methods regarding whether they
are tolerable or not in the dynamic circumstance, that is, whether the
times of re-routing are small or not. These new methods are revised
methods that are based on the traditional methods. We recommended
the method which produces the smallest routing cost in the dynamic
circumstance, therefore producing the smallest total cost.
Abstract: Photovoltaic (PV) systems provides a viable means of
power generation for applications like powering residential
appliances, electrification of villages in rural areas, refrigeration and
water pumping. Photovoltaic-power generation is reliable. The
operation and maintenance costs are very low. Since Myanmar is a
land of plentiful sunshine, especially in central and southern regions
of the country, the solar energy could hopefully become the final
solution to its energy supply problem in rural area.
Abstract: In this paper, we evaluate the performance of the
Hybrid-MIMO Receiver Scheme (HMRS) in Cognitive Radio
network (CR-network). We investigate the efficiency of the proposed
scheme which the energy level and user number of primary user are
varied according to the characteristic of CR-network. HMRS can
allow users to transmit either Space-Time Block Code (STBC) or
Spatial-Multiplexing (SM) streams simultaneously by using
Successive Interference Cancellation (SIC) and Maximum Likelihood
Detection (MLD). From simulation, the results indicate that the
interference level effects to the performance of HMRS. Moreover,
the exact closed-form capacity of the proposed scheme is derived and
compared with STBC scheme.
Abstract: The present study addresses problems and solutions
related to new functional food production. Wheat (Triticum aestivum
L) bran obtained from industrial mill company “Dobeles
dzirnavieks”, was used to investigate them as raw material like
nutrients for Bifidobacterium lactis Bb-12. Enzymatic hydrolysis of
wheat bran starch was carried out by α-amylase from Bacillus
amyloliquefaciens (Sigma Aldrich). The Viscozyme L purchased
from (Sigma Aldrich) were used for reducing released sugar.
Bifidibacterium lactis Bb-12 purchased from (Probio-Tec® CHR
Hansen) was cultivated in enzymatically hydrolysed wheat bran
mash. All procedures ensured the number of active Bifidobacterium
lactis Bb-12 in the final product reached 105 CFUg-1. After enzymatic
and bacterial fermentations sample were freeze dried for analysis of
chemical compounds. All experiments were performed at Faculty of
Food Technology of Latvia University of Agriculture in January-
March 2013. The obtained results show that both types of wheat bran
(enzymatically treated and non-treated) influenced the fermentative
activity and number of Bifidibacterium lactis Bb-12 viable in wheat
bran mash. Amount of acidity strongly increase during the wheat
bran mash fermentation. The main objective of this work was to
create low-energy functional enzymatically and bacterially treated
food from wheat bran using enzymatic hydrolysis of carbohydrates
and following cultivation of Bifidobacterium lactis Bb-12.
Abstract: Aggregation behavior of sodium salicylate and sodium cumene sulfonate was studied in aqueous solution at different temperature. Specific conductivity and relative viscosity were measured at different temperature to find minimum hydrotropic concentration. The thermodynamic parameters (free energy, enthalpy and entropy) were evaluated in the temperature range of 30°C-70°C. The free energy decreased with increase in temperature. The aggregation was found to be exothermic in nature and favored by positive value of entropy.
Abstract: 98% of the energy needed in Taiwan has been
imported. The prices of petroleum and electricity have been
increasing. In addition, facility capacity, amount of electricity
generation, amount of electricity consumption and number of Taiwan
Power Company customers have continued to increase. For these
reasons energy conservation has become an important topic. In the
past linear regression was used to establish the power consumption
models for chillers. In this study, grey prediction is used to evaluate
the power consumption of a chiller so as to lower the total power
consumption at peak-load (so that the relevant power providers do not
need to keep on increasing their power generation capacity and facility
capacity).
In grey prediction, only several numerical values (at least four
numerical values) are needed to establish the power consumption
models for chillers. If PLR, the temperatures of supply chilled-water
and return chilled-water, and the temperatures of supply cooling-water
and return cooling-water are taken into consideration, quite accurate
results (with the accuracy close to 99% for short-term predictions)
may be obtained. Through such methods, we can predict whether the
power consumption at peak-load will exceed the contract power
capacity signed by the corresponding entity and Taiwan Power
Company. If the power consumption at peak-load exceeds the power
demand, the temperature of the supply chilled-water may be adjusted
so as to reduce the PLR and hence lower the power consumption.