Abstract: This work deals with the experimental study of the mechanical behavior, by shear tests (fracture shear), elements of concrete beams reinforced with fibers in chips. These fibers come from the machining waste of the steel parts. The shear tests are carried out on prismatic specimens of dimensions 10 x 20 x 120 cm3. The fibers are characterized by mechanical resistance and tearing. The optimal composition of the concrete was determined by the workability test. Two fiber contents are selected for this study (W = 0.6% and W = 0.8%) and a BT control concrete (W = 0%) of the same composition as the matrix is developed to serve as a reference with a sand-to-gravel ratio (S/G) of concrete matrix equal to 1. The comparison of the different results obtained shows that the chips fibers confer a significant ductility to the material after cracking of the concrete. Also, the fibers used limit diagonal cracks in shear and improve strength and rigidity.
Abstract: An experimental program is conducted in this research to investigate the influence of basalt fibers and steel fibers on the flexural behavior of RC beams. Reinforced concrete beams are constructed using steel fiber concrete and basalt fiber concrete. Steel and basalt fibers are included in a percentage of 15% and 2.5% of the total cement weight, respectively. Test results have shown that basalt fibers have increased the load carrying capacity of the beams up to 30% and the maximum deflection to almost 2.4 times that measured in the control specimen. It has also shown that steel fibers have increased the load carrying capacity of the beams up to 47% and the ultimate deflection is almost duplicated compared to the control beam. Steel and basalt fibers have increased the ductility of the reinforced concrete beams.
Abstract: The present paper reports the cracking moment estimates of a set of steel-reinforced, Fiber Reinforced Polymer (FRP)-reinforced and hybrid steel-FRP reinforced concrete beams, calculated from different analytical formulations in the codes, together with the experimental cracking load values. A total of three steel-reinforced, four FRP-reinforced, 12 hybrid FRP-steel over-reinforced and five hybrid FRP-steel under-reinforced concrete beam tests were analyzed within the scope of the study. Glass FRP (GFRP) and Basalt FRP (BFRP) bars were used in the beams as FRP bars. In under-reinforced hybrid beams, rupture of the FRP bars preceded crushing of concrete, while concrete crushing preceded FRP rupture in over-reinforced beams. In both types, steel yielding took place long before the FRP rupture and concrete crushing. The cracking moment mainly depends on two quantities, namely the moment of inertia of the section at the initiation of cracking and the flexural tensile strength of concrete, i.e. the modulus of rupture. In the present study, two different definitions of uncracked moment of inertia, i.e. the gross and the uncracked transformed moments of inertia, were adopted. Two analytical equations for the modulus of rupture (ACI 318M and Eurocode 2) were utilized in the calculations as well as the experimental tensile strength of concrete from prismatic specimen tests. The ACI 318M modulus of rupture expression produced cracking moment estimates closer to the experimental cracking moments of FRP-reinforced and hybrid FRP-steel reinforced concrete beams when used in combination with the uncracked transformed moment of inertia, yet the Eurocode 2 modulus of rupture expression gave more accurate cracking moment estimates in steel-reinforced concrete beams. All of the analytical definitions produced analytical values considerably different from the experimental cracking load values of the solely FRP-reinforced concrete beam specimens.
Abstract: There is little published research about the influence of execution methods on structural behavior. Structural analysis is typically based on a constructed building, considering the actions of all forces under which it was designed. However, during construction, execution loads do not match those designed, and in some cases the loads begin to act when the concrete has not yet reached its maximum strength. Changes to structural element support conditions may occur, resulting in unforeseen alterations to the structure’s behavior. Shoring is an example of a construction process that, if executed improperly, will directly influence the structural performance, and may result in unpredicted cracks and displacements. The NBR 14931/2004 standard, which guides the execution of reinforced concrete structures, mentions that shoring must be executed in a way that avoids unpredicted loads and that it may be removed after previous analysis of the structure’s behavior by the professional responsible for the structure’s design. Differences in structural behavior are reduced for small spans. It is important to qualify and quantify how the incorrect placement of shores can compromise a structure’s safety. The results of this research allowed a more precise acknowledgment of the relationship between spans and loads, for which the influence of execution processes can be considerable, and reinforced that civil engineering practice must be performed with the presence of a qualified professional, respecting existing standards’ guidelines.
Abstract: 5
In order to eradicate the degradation of reinforced concrete structures due to the steel corrosion, professionals in constructions suggest using fiber reinforced polymers (FRP) for their excellent properties. Nevertheless, high temperatures may affect the bond between FRP bar and concrete, and consequently the serviceability of FRP-reinforced concrete structures. This paper presents a nonlinear numerical investigation using ADINA software to investigate the effect of the spacing between glass FRP (GFRP) bars embedded in concrete on circumferential thermal deformations and the distribution of radial thermal cracks in reinforced concrete beams submitted to high temperature variations up to 60 °C for asymmetrical problems. The thermal deformations predicted from nonlinear finite elements model, at the FRP bar/concrete interface and at the external surface of concrete cover, were established as a function of the ratio of concrete cover thickness to FRP bar diameter (c/db) and the ratio of spacing between FRP bars in concrete to FRP bar diameter (e/db). Numerical results show that the circumferential thermal deformations at the external surface of concrete cover are linear until cracking thermal load varied from 32 to 55 °C corresponding to the ratio of e/db varied from 1.3 to 2.3, respectively. However, for ratios e/db >2.3 and c/db >1.6, the thermal deformations at the external surface of concrete cover exhibit linear behavior without any cracks observed on the specified surface. The numerical results are compared to those obtained from analytical models validated by experimental tests.
Abstract: Fibre reinforced concrete (FRC) has been widely used in industrial pavements and non-structural elements such as pipes, culverts, tunnels, and precast elements. The strengthening effect of fibres in the concrete matrix is achieved primarily due to the bridging effect of fibres at the crack interfaces. The workability of the concrete was reduced on addition of high percentages of steel fibres. The optimum percentage of addition of steel fibres varies with its aspect ratio. For this study, 1% addition of steel has resulted to be the optimum percentage for both Hooked and Crimped Steel Fibres and was added to the beam specimens. The fibres restrain efficiently the cracks and take up residual stresses beyond the cracking. In this sense, diagonal cracks are effectively stitched up by fibres crossing it. The failure of beams within the shear failure range changed from shear to flexure in the presence of sufficient steel fibre quantity. The shear strength is increased with the addition of steel fibres and had exceeded the enhancement obtained with the transverse reinforcement. However, such increase is not directly in proportion with the quantity of fibres used. Considering all the clarification made in the present experimental investigation, it is concluded that 1% of crimped steel fibres with an aspect ratio of 50 is the best type of steel fibres for replacement of transverse stirrups in high strength concrete beams when compared to the steel fibres with hooked ends.
Abstract: Reinforced concrete (RC) beams rarely undergo lateral-torsional buckling (LTB), since these beams possess large lateral bending and torsional rigidities owing to their stocky cross-sections, unlike steel beams. However, the problem of LTB is becoming more and more pronounced in the last decades as the span lengths of concrete beams increase and the cross-sections become more slender with the use of pre-stressed concrete. The buckling moment of a beam mainly depends on its lateral bending rigidity and torsional rigidity. The nonhomogeneous and elastic-inelastic nature of RC complicates estimation of the buckling moments of concrete beams. Furthermore, the lateral bending and torsional rigidities of RC beams and the buckling moments are affected from different forms of concrete cracking, including flexural, torsional and restrained shrinkage cracking. The present study pertains to the effects of concrete cracking on the torsional rigidities of RC beams prone to elastic LTB. A series of tests on rather slender RC beams indicated that torsional cracking does not initiate until buckling in elastic LTB, while flexural cracking associated with lateral bending takes place even at the initial stages of loading. Hence, the present study clearly indicated that the un-cracked torsional rigidity needs to be used for estimating the buckling moments of RC beams liable to elastic LTB.
Abstract: This paper presents a proposed analytical model for predicting the shear strength of reinforced concrete beams strengthened with CFRP composites as external reinforcement. The proposed analytical model can predict the shear contribution of CFRP composites of RC beams with an acceptable coefficient of correlation with the tested results. Based on the comparison of the proposed model with the published well-known models (ACI model, Triantafillou model, and Colotti model), the ACI model had a wider range of 0.16 to 10.08 for the ratio between tested and predicted ultimate shears at failure. Also, an acceptable range of 0.27 to 2.78 for the ratio between tested and predicted ultimate shears by the Triantafillou model. Finally, the best prediction (the ratio between the tested and predicted ones) of the ultimate shear capacity is observed by using Colotti model with a range of 0.20 to 1.78. Thus, the contribution of the CFRP composites as external reinforcement can be predicted with high accuracy by using the proposed analytical model.
Abstract: This paper deals with a nonlinear finite element analysis to examine the behavior up to failure of cantilever composite steel-concrete beams which are prestressed externally. 'Pre-' means stressing the high strength external tendons in the steel beam section before the concrete slab is added. The composite beam contains a concrete slab which is connected together with steel I-beam by means of perfect shear connectors between the concrete slab and the steel beam which is subjected to static loading. A finite element analysis will be done to study the effects of external prestressed tendons on the composite steel-concrete beams by locating the tendons in different locations (profiles). ANSYS version 12.1 computer program is being used to analyze the represented three-dimensional model of the cantilever composite beam. This model gives all these outputs, mainly load-displacement behavior of the cantilever end and in the middle span of the simple support part.
Abstract: This paper investigates and evaluates experimentally the structural behavior of high strength concrete (HSC) beams under fire and compares it with that of Normal strength concrete (NSC) beams. The main investigated parameters are: concrete compressive strength (300 or 600 kg/cm2); the concrete cover thickness (3 or 5 cm); the degree of temperature (room temperature or 600 oC); the type of cooling (air or water); and the fire exposure time (3 or 5 hours). Test results showed that the concrete compressive strength decreases significantly as the exposure time to fire increases.
Abstract: This study presents an overview of the work carried out by the use of wood waste as coarse aggregate in mortar. The paper describes experimental and numerical investigations carried on pervious concrete made of wood chips and also sheds lights on the mechanical properties of this new product. The properties of pervious wood-concrete such as strength, elastic modulus, and failure modes are compared and evaluated. The characterization procedure of the mechanical properties of wood waste ash are presented and discussed. The numerical and tested load–deflection response results are compared. It was observed that the numerical results are in good agreement with the experimental results.
Abstract: This paper presents the results of experimental and theoretical investigations of the mechanisms of crack formation in reinforced concrete beams subjected to quasi-static bending. The boundary-value problem has been formulated in the framework of brittle fracture mechanics and has been solved by using the finite-element method. Numerical simulation of the vibrations of an uncracked beam and a beam with cracks of different size serves to determine the pattern of changes in the spectrum of eigenfrequencies observed during crack evolution. Experiments were performed on the sequential quasistatic four-point bending of the beam leading to the formation of cracks in concrete. At each loading stage, the beam was subjected to an impulse load to induce vibrations. Two stages of cracking were detected. At the first stage the conservative process of deformation is realized. The second stage is an active cracking, which is marked by a sharp change in eingenfrequencies. The boundary of a transition from one stage to another is well registered. The vibration behavior was examined for the beams strengthened by carbon-fiber sheet before loading and at the intermediate stage of loading after the grouting of initial cracks. The obtained results show that the vibrodiagnostic approach is an effective tool for monitoring of cracking and for assessing the quality of measures aimed at strengthening concrete structures.
Abstract: Fabric form-work is a technique to cast concrete structures with a great advantage of saving concrete material of up to 40%. This technique is particularly associated with the optimized concrete structures that usually have smaller cross-section dimensions than equivalent prismatic members. However, this can make the structural system produced from these members prone to smaller serviceability safety margins. Therefore, it is very important to understand the serviceability issue of non-prismatic concrete structures. In this paper, an analytical computer-based model to optimize concrete beams and to predict load-deflection behaviour of both prismatic and non-prismatic concrete beams is presented. The model was developed based on the method of sectional analysis and integration of curvatures. Results from the analytical model were compared to load-deflection behaviour of a number of beams with different geometric and material properties from other researchers. The results of the comparison show that the analytical program can accurately predict the load-deflection response of concrete beams with medium reinforcement ratios. However, it over-estimates deflection values for lightly reinforced specimens. Finally, the analytical program acceptably predicted load-deflection behaviour of on-prismatic concrete beams.
Abstract: This paper presents the flexural response of Reinforced Geopolymer Concrete (RGPC) beams. A commercial finite element (FE) software ABAQUS has been used to perform a structural behavior of RGPC beams. Using parameters such: stress, strain, Young’s modulus, and Poisson’s ratio obtained from experimental results, a beam model has been simulated in ABAQUS. The results from experimental tests and ABAQUS simulation were compared. Due to friction forces at the supports and loading rollers; slip occurring, the actual deflection of RGPC beam from experimental test results were slightly different from the results of ABAQUS. And there is good agreement between the crack patterns of fly ash-based geopolymer concrete generated by FE analysis using ABAQUS, and those in experimental data.
Abstract: The study conducted a simulation of the effect of sea
water to the bonding capacity of GFRP sheet on the concrete beams
using a simulation tank. Fiber reinforced polymer (FRP) has been
developed and applied in many fields civil engineering structures on
the new structures and also for strengthening of the deteriorated
structures. The FRP has advantages such as its corrosion resistance as
well as high tensile strength to weight ratio. Compared to the other
FRP materials, Glass composed FRP (GFRP) is relatively cheaper.
GFRP sheet is applied externally by bonding it on the concrete surface.
The studies regarding the application of GFRP sheet have been
conducted such as strengthening system, bonding behavior of GFRP
sheet including the application as reinforcement in new structures. For
application to the structures with direct contact to sea environment, a
study regarding the effect of sea water to the bonding capacity of
GFRP sheet is important to be clarified. To achieve the objective of the
study, a series of concrete beams strengthened with GFRP sheet on
extreme tension surface were prepared. The beams then were stored on
the sea water tank for six months. Results indicated the bonding
capacity decreased after six month exposed to the sea water.
Abstract: The current study aims to highlight the loading
characteristics impact on the time evolution (focusing particularly on
long term effects) of the deformation of realized reinforced concrete
beams. Namely the tension stiffening code provisions (i.e. within
Eurocode 2) are reviewed with a clear intention to reassess their
operational value and predicting capacity. In what follows the
experimental programme adopted along with some preliminary
findings and numerical modeling attempts are presented. For a range of long slender reinforced concrete simply supported
beams (4200 mm) constant static sustained and repeated cyclic
loadings were applied mapping the time evolution of deformation.
All experiments were carried out at the Heavy Structures Lab of the
University of Leeds. During tests the mid-span deflection, creep
coefficient and shrinkage strains were monitored for duration of 90
days. The obtained results are set against the values predicted by
Eurocode 2 and the tools within an FE commercial package (i.e.
Midas FEA) to yield that existing knowledge and practise is at times
over-conservative.
Abstract: When high strength reinforced concrete is exposed to
high temperature due to a fire, deteriorations occur such as loss in
strength and elastic modulus, cracking and spalling of the concrete.
Therefore, it is important to understand risk of structural safety in
building structures by studying structural behaviors and rehabilitation
of fire damaged high strength concrete structures. This paper aims at
investigating rehabilitation effect on fire damaged high strength
concrete beams using experimental and analytical methods. In the
experiments, flexural specimens with high strength concrete are
exposed to high temperatures according to ISO 834 standard time
temperature curve. From four-point loading test, results show that
maximum loads of the rehabilitated beams are similar to or higher than
those of the non-fire damaged RC beam. In addition, structural
analyses are performed using ABAQUS 6.10-3 with same conditions
as experiments to provide accurate predictions on structural and
mechanical behaviors of rehabilitated RC beams. The parameters are
the fire cover thickness and strengths of repairing mortar. Analytical
results show good rehabilitation effects, when the results predicted
from the rehabilitated models are compared to structural behaviors of
the non-damaged RC beams. In this study, fire damaged high strength concrete beams are
rehabilitated using polymeric cement mortar. The predictions from the
finite element (FE) models show good agreements with the
experimental results and the modeling approaches can be used to
investigate applicability of various rehabilitation methods for further
study.
Abstract: In recent years, fire accidents have been steadily
increased and the amount of property damage caused by the accidents
has gradually raised. Damaging building structure, fire incidents bring
about not only such property damage but also strength degradation and
member deformation. As a result, the building structure undermines its
structural ability. Examining the degradation and the deformation is
very important because reusing the building is more economical than
reconstruction. Therefore, engineers need to investigate the strength
degradation and member deformation well, and make sure that they
apply right rehabilitation methods. This study aims at evaluating
deformation characteristics of fire damaged and rehabilitated normal
strength concrete beams through both experiments and finite element
analyses. For the experiments, control beams, fire damaged beams and
rehabilitated beams are tested to examine deformation characteristics.
Ten test beam specimens with compressive strength of 21MPa are
fabricated and main test variables are selected as cover thickness of
40mm and 50mm and fire exposure time of 1 hour or 2 hours. After
heating, fire damaged beams are air-recurred for 2 months and
rehabilitated beams are repaired with polymeric cement mortar after
being removed the fire damaged concrete cover. All beam specimens
are tested under four points loading. FE analyses are executed to
investigate the effects of main parameters applied to experimental
study. Test results show that both maximum load and stiffness of the
rehabilitated beams are higher than those of the fire damaged beams.
In addition, predicted structural behaviors from the analyses also show
good rehabilitation effect and the predicted load-deflection curves are
similar to the experimental results. For the further, the proposed
analytical method can be used to predict deformation characteristics of
fire damaged and rehabilitated concrete beams without suffering from
time and cost consuming of experimental process.
Abstract: A large amount of blast furnace slag is generated in
China. Most ground granulated blast furnace slag (GGBS) however
ends up in low-grade applications. Blast furnace slag, ground to an
appropriate fineness, can be used as a partial replacement of
cementitious material in concrete. The potential for using GGBS in
structural concrete, e.g. concrete beams and columns is investigated
at Xi’an Jiaotong-Liverpool University (XJTLU). With 50% of CEM
I cement replaced with GGBS, peak hydration temperatures
determined in a suspended concrete slab reduced by 20%. This
beneficiary effect has not been further improved with 70% of CEM I
replaced with GGBS. Partial replacement of CEM I with GGBS has a
retardation effect on the early-age strength of concrete. More GGBS
concrete mixes will be conducted to identify an ‘optimum’
replacement level which will lead to a reduced thermal loading,
without significantly compromising the early-age strength of
concrete.
Abstract: In this paper, a nonlinear Finite Element Analysis
(FEA) was carried out using ANSYS software to build a model able
of predicting the behavior of Reinforced Concrete (RC) beams with
unbonded reinforcement. The FEA model was compared to existing
experimental data by other researchers. The existing experimental
data consisted of 16 beams that varied from structurally sound beams
to beams with unbonded reinforcement with different unbonded
lengths and reinforcement ratios. The model was able to predict the
ultimate flexural strength, load-deflection curve, and crack pattern of
concrete beams with unbonded reinforcement. It was concluded that
when the when the unbonded length is less than 45% of the span,
there will be no decrease in the ultimate flexural strength due to the
loss of bond between the steel reinforcement and the surrounding
concrete regardless of the reinforcement ratio. Moreover, when the
reinforcement ratio is relatively low, there will be no decrease in
ultimate flexural strength regardless of the length of unbond.