Abstract: We present a new framework of the data-reusing (DR)
adaptive algorithms by incorporating a constraint on noise, referred
to as a noise constraint. The motivation behind this work is that the
use of the statistical knowledge of the channel noise can contribute
toward improving the convergence performance of an adaptive filter
in identifying a noisy linear finite impulse response (FIR) channel.
By incorporating the noise constraint into the cost function of the
DR adaptive algorithms, the noise constrained DR (NC-DR) adaptive
algorithms are derived. Experimental results clearly indicate their
superior performance over the conventional DR ones.
Abstract: We present a new subband adaptive filter (R-SAF)
which is robust against impulsive noise in system identification. To
address the vulnerability of adaptive filters based on the L2-norm
optimization criterion against impulsive noise, the R-SAF comes from
the L1-norm optimization criterion with a constraint on the energy
of the weight update. Minimizing L1-norm of the a posteriori error
in each subband with a constraint on minimum disturbance gives
rise to the robustness against the impulsive noise and the capable
convergence performance. Experimental results clearly demonstrate
that the proposed R-SAF outperforms the classical adaptive filtering
algorithms when impulsive noise as well as background noise exist.
Abstract: In Ultra high-field MRI scanners (3T and higher),
parallel RF transmission techniques using multiple RF chains with
multiple transmit elements are a promising approach to overcome
the high-field MRI challenges in terms of inhomogeneity in the RF
magnetic field and SAR. However, mutual coupling between the
transmit array elements disturbs the desirable independent control of
the RF waveforms for each element. This contribution demonstrates
a 18 dB improvement of decoupling (isolation) performance due to
the very low output impedance of our 1 kW power amplifier.
Abstract: In this paper, we analyze NEtwork MObility (NEMO) supporting problems in Content-Centric Networking (CCN), and propose the CCN-NEMO which can well support the deployment of the content-centric paradigm in large-scale mobile Internet. The CCN-NEMO extends the signaling message of the basic CCN protocol, to support the mobility discovery and fast trigger of Interest re-issuing during the network mobility. Besides, the Mobile Router (MR) is extended to optimize the content searching and relaying in the local subnet. These features can be employed by the nested NEMO to maximize the advantages of content retrieving with CCN. Based on the analysis, we compare the performance on handover latency between the basic CCN and our proposed CCN-NEMO. The results show that our scheme can facilitate the content-retrieving in the NEMO scenario with improved performance.
Abstract: In this work, we use the Fault detection and isolation and the Fault tolerant control based on sliding mode observer in order to introduce the well diagnosis of a nonlinear system. The robustness of the proposed observer for the two techniques is tested through a physical example. The results in this paper show the interaction between the Fault tolerant control and the Diagnosis procedure.
Abstract: In this paper, a single phase soft switched Zero Voltage Transition and Zero Current Transition (ZVT-ZCT) Power Factor Correction (PFC) boost converter is proposed. In the proposed PFC converter, the main switch turns on with ZVT and turns off with ZCT without any additional voltage or current stresses. Auxiliary switch turns on and off with zero current switching (ZCS). Also, the main diode turns on with zero voltage switching (ZVS) and turns off with ZCS. The proposed converter has features like low cost, simple control and structure. The output current and voltage are controlled by the proposed PFC converter in wide line and load range. The theoretical analysis of converter is clarified and the operating steps are given in detail. The simulation results of converter are obtained for 500 W and 100 kHz. It is observed that the semiconductor devices operate with soft switching (SS) perfectly. So, the switching power losses are minimum. Also, the proposed converter has 0.99 power factor with sinusoidal current shape.
Abstract: We investigate the performance of an integrated cascade (IC) refrigeration system which uses environment friendly zeotropic mixtures. Computational calculation has been carried out by varying pressure level at the evaporator and the condenser of the system. Effects of mass flow rate of the refrigerant on the coefficient of performance (COP) are presented. We show that the integrated cascade system produces ultra-low temperatures in the evaporator by using environment friendly zeotropic mixture.
Abstract: In this paper, an improved active snubber cell is proposed on account of soft switching (SS) family of pulse width modulation (PWM) DC-DC converters. The improved snubber cell provides zero-voltage transition (ZVT) turn on and zero-current transition (ZCT) turn off for main switch. The snubber cell decreases EMI noise and operates with SS in a wide range of line and load voltages. Besides, all of the semiconductor devices in the converter operate with SS. There is no additional voltage and current stress on the main devices. Additionally, extra voltage stress does not occur on the auxiliary switch and its current stress is acceptable value. The improved converter has a low cost and simple structure. The theoretical analysis of converter is clarified and the operating states are given in detail. The experimental results of converter are obtained by prototype of 500 W and 100 kHz. It is observed that the experimental results and theoretical analysis of converter are suitable with each other perfectly.
Abstract: This project aims at building an efficient and
automatic power monitoring SCADA system, which is capable of
monitoring the electrical parameters of high voltage powered devices
in real time for example RMS voltage and current, frequency, energy
consumed, power factor etc. The system uses RS-485 serial
communication interface to transfer data over longer distances.
Embedded C programming is the platform used to develop two
hardware modules namely: RTU and Master Station modules, which
both use the CC2540 BLE 4.0 microcontroller configured in slave /
master mode. The Si8900 galvanic ally isolated microchip is used to
perform ADC externally. The hardware communicates via UART
port and sends data to the user PC using the USB port. Labview
software is used to design a user interface to display current state of
the power loads being monitored as well as logs data to excel
spreadsheet file. An understanding of the Si8900’s auto baud rate
process is key to successful implementation of this project.
Abstract: This paper presents an analysis study on the impacts
of the changes of the capacitor banks, the loss of a transformer, and
the installation of distributed generation on the voltage total harmonic
distortion and harmonic resonance. The study is applied in a real
system in Oman, Sohar Industrial Port–C Substation Network.
Frequency scan method and Fourier series analysis method are used
with the help of EDSA software. Moreover, the results are compared
with limits specified by national Oman distribution code.
Abstract: Present study focused on the utilization of solar
energy by the help of photovoltaic greenhouse solar dryer under
forced mode. A single slope photovoltaic greenhouse solar dryer has
been proposed and thermal modelling has been developed. Various
parameters have been calculated by thermal modelling such as
greenhouse room temperature, cell temperature, crop temperature and
air temperature at exit of greenhouse. Further cell efficiency, thermal
efficiency, and overall thermal efficiency have been calculated for a
typical day of May and November. It was found that system can
generate equivalent thermal energy up to 7.65 kW and 6.66 kW per
day for clear day of May and November respectively.
Abstract: Device-to-device (D2D) communication is considered a
promising technique to provide wireless peer-to-peer communication
services. Due to increasing demand on mobile services, available
spectrum for radio frequency (RF) based communications becomes
scarce. Recently, visible light communications (VLC) has evolved
as a high speed wireless data transmission technology for indoor
environments with abundant available bandwidth. In this paper,
a novel VLC based D2D communication that provides wireless
peer-to-peer communication is proposed. Potential low operating
power devices for an efficient D2D communication over increasing
distance of separation between devices is analyzed. Optical repeaters
(OR) are also proposed to enhance the performance in an environment
where direct D2D communications yield degraded performance.
Simulation results show that VLC plays an important role in
providing efficient D2D communication up to a distance of 1 m
between devices. It is also found that the OR significantly improves
the coverage distance up to 3.5 m.
Abstract: In this paper, a desiccant solar unit for air
conditioning and desalination is presented first. Secondly, a dynamic
modelling study of the desiccant wheel is developed. After that, a
simulation study and an experimental investigation of the behaviour
of desiccant wheel are developed. The experimental investigation is
done in the chamber of commerce in Freiburg-Germany. Indeed, the
variations of calculated and measured temperatures and specific
humidity of dehumidified and rejected air are presented where a good
agreement is found when comparing the model predictions with
experimental data under the considered range of operating conditions.
Finally, the study of the compartments of desalination and water
condensation shows that the unit can produce an acceptable quantity
of water at the same time of the air conditioning operation.
Abstract: The Flexible AC Transmission System (FACTS)
technology is a new advanced solution that increases the reliability
and provides more flexibility, controllability, and stability of a power
system. The Unified Power Flow Controller (UPFC), as the most
versatile FACTS device for regulating power flow, is able to control
respectively transmission line real power, reactive power, and node
voltage. The main purpose of this paper is to analyze the effect of the
UPFC on the load flow, the power losses, and the voltage stability
using NEPLAN software modules, Newton-Raphson load flow is
used for the power flow analysis and the modal analysis is used for
the study of the voltage stability. The simulation was carried out on
the IEEE 14-bus test system.
Abstract: Solar water heating is a thermodynamic process of
heating water using sunlight with the help of solar water heater. Thus,
solar water heater is a device used to harness solar energy. In this
paper, a modified solar water heating system (MSWHS) has been
proposed over flat plate collector (FPC) and Evacuated tube collector
(ETC). The modifications include selection of materials other than
glass, and glass wool which are conventionally used for fabricating
FPC and ETC. Some modifications in design have also been
proposed. Its collector is made of double layer of semi-cylindrical
acrylic tubes and fibre reinforced plastic (FRP) insulation base. Water
tank is made of double layer of acrylic sheet except base and north
wall. FRP is used in base and north wall of the water tank. A concept
of equivalent thickness has been utilised for calculating the
dimensions of collector plate, acrylic tube and tank. A thermal model for the proposed design of MSWHS is developed
and simulation is carried out on MATLAB for the capacity of 200L
MSWHS having collector area of 1.6 m2, length of acrylic tubes of
2m at an inclination angle 25° which is taken nearly equal to the
latitude of the given location. Latitude of Allahabad is 24.45° N. The
results show that the maximum temperature of water in tank and tube
has been found to be 71.2°C and 73.3°C at 17:00hr and 16:00hr
respectively in March for the climatic data of Allahabad. Theoretical performance analysis has been carried out by varying
number of tubes of collector, the tank capacity and climatic data for
given months of winter and summer.
Abstract: The cumulative costs for O&M may represent as
much as 65%-90% of the turbine's investment cost. Nowadays the
cost effectiveness concept becomes a decision-making and
technology evaluation metric. The cost of energy metric accounts for
the effect replacement cost and unscheduled maintenance cost
parameters. One key of the proposed approach is the idea of
maintaining the WTs which can be captured via use of a finite state
Markov chain. Such a model can be embedded within a probabilistic
operation and maintenance simulation reflecting the action to be
done. In this paper, an approach of estimating the cost of O&M is
presented. The finite state Markov model is used for decision
problems with number of determined periods (life cycle) to predict
the cost according to various options of maintenance.
Abstract: The power buck converter is the most widely used
DC/DC converter topology. They have a very large application area
such as DC motor drives, photovoltaic power system which require
fast transient responses and high efficiency over a wide range of load
current. This work proposes, the modelling of DC/DC power buck
converter using state-space averaging method and the current-mode
control using a proportional-integral controller. The efficiency of the
proposed model and control loop are evaluated with operating point
changes. The simulation results proved the effectiveness of the linear
model of DC/DC power buck converter.
Abstract: This paper investigates the effects of breaks in bonds,
breaks in the earthing system and breaks in earth wire on the rise of
the earth potential (EPR) in a substation and at the transmission tower
bases using various models of an L6 tower. Different approaches
were adopted to examine the integrity of the earthing system and the
terminal towers. These effects were investigated to see the associated
difference in the EPR magnitudes with respect to a healthy system at
various locations. Comparisons of the computed EPR magnitudes
were then made between the healthy and unhealthy system to detect
any difference. The studies were conducted at power frequency for a
uniform soil with different soil resistivities. It was found that full
breaks in the double bond of the terminal towers increase the EPR
significantly at the fault location, while they reduce EPR at the
terminal tower bases. A fault on the isolated section of the grid can
result in EPR values up to 8 times of those on a healthy system at
higher soil resistivities, provided that the extended earthing system
stays connected to the grid.
Abstract: Smart metering and demand response are gaining
ground in industrial and residential applications. Smart Appliances
have been given concern towards achieving Smart home. The success
of Smart grid development relies on the successful implementation of
Information and Communication Technology (ICT) in power sector.
Smart Appliances have been the technology under development and
many new contributions to its realization have been reported in the
last few years. The role of ICT here is to capture data in real time,
thereby allowing bi-directional flow of information/data between
producing and utilization point; that lead a way for the attainment of
Smart appliances where home appliances can communicate between
themselves and provide a self-control (switch on and off) using the
signal (information) obtained from the grid. This paper depicts the
background on ICT for smart appliances paying a particular attention
to the current technology and identifying the future ICT trends for
load monitoring through which smart appliances can be achieved to
facilitate an efficient smart home system which promote demand
response program. This paper grouped and reviewed the recent
contributions, in order to establish the current state of the art and
trends of the technology, so that the reader can be provided with a
comprehensive and insightful review of where ICT for smart
appliances stands and is heading to. The paper also presents a brief
overview of communication types, and then narrowed the discussion
to the load monitoring (Non-intrusive Appliances Load Monitoring
‘NALM’). Finally, some future trends and challenges in the further
development of the ICT framework are discussed to motivate future
contributions that address open problems and explore new
possibilities.
Abstract: Voltage level must be raised in order to deliver the
produced energy to the consumption zones with less loss and less
cost. Power transformers used to raise or lower voltage are important
parts of the energy transmission system. Power transformers used in
switchgear and power generation plants stay in human's intensive
habitat zones as a result of expanding cities. Accordingly, noise
levels produced by power transformers have begun more and more
important and they have established itself as one of the research field.
In this research, the noise cause on transformers has been
investigated, it's causes has been examined and noise measurement
techniques have been introduced. Examples of transformer noise test
results are submitted and precautions to be taken were discussed for
the purpose of decreasing of the noise which will occurred by
transformers.