Abstract: The apportionment method is used by many countries, to calculate the distribution of seats in political bodies. For example, this method is used in the United States (U.S.) to distribute house seats proportionally based on the population of the electoral district. Famous apportionment methods include the divisor methods called the Adams Method, Dean Method, Hill Method, Jefferson Method and Webster Method. Sometimes the results from the implementation of these divisor methods are unfair and include errors. Therefore, it is important to examine the optimization of this method by using a bias measurement to figure out precise and fair results. In this research we investigate the bias of divisor methods in the U.S. Houses of Representatives toward large and small states by applying the Stolarsky Mean Method. We compare the bias of the apportionment method by using two famous bias measurements: the Balinski and Young measurement and the Ernst measurement. Both measurements have a formula for large and small states. The Third measurement however, which was created by the researchers, did not factor in the element of large and small states into the formula. All three measurements are compared and the results show that our measurement produces similar results to the other two famous measurements.
Abstract: One of the most important challenging factors in
medical images is nominated as noise. Image denoising refers to the
improvement of a digital medical image that has been infected by
Additive White Gaussian Noise (AWGN). The digital medical image
or video can be affected by different types of noises. They are
impulse noise, Poisson noise and AWGN. Computed tomography
(CT) images are subjects to low quality due to the noise. Quality of
CT images is dependent on absorbed dose to patients directly in such
a way that increase in absorbed radiation, consequently absorbed
dose to patients (ADP), enhances the CT images quality. In this
manner, noise reduction techniques on purpose of images quality
enhancement exposing no excess radiation to patients is one the
challenging problems for CT images processing. In this work, noise
reduction in CT images was performed using two different
directional 2 dimensional (2D) transformations; i.e., Curvelet and
Contourlet and Discrete Wavelet Transform (DWT) thresholding
methods of BayesShrink and AdaptShrink, compared to each other
and we proposed a new threshold in wavelet domain for not only
noise reduction but also edge retaining, consequently the proposed
method retains the modified coefficients significantly that result good
visual quality. Data evaluations were accomplished by using two
criterions; namely, peak signal to noise ratio (PSNR) and Structure
similarity (Ssim).
Abstract: In this paper, we present a model-based regression test
suite reducing approach that uses EFSM model dependence analysis
and probability-driven greedy algorithm to reduce software regression
test suites. The approach automatically identifies the difference
between the original model and the modified model as a set of
elementary model modifications. The EFSM dependence analysis is
performed for each elementary modification to reduce the regression
test suite, and then the probability-driven greedy algorithm is adopted
to select the minimum set of test cases from the reduced regression test
suite that cover all interaction patterns. Our initial experience shows
that the approach may significantly reduce the size of regression test
suites.