Abstract: A lightpipe is an about 99 percent specular reflective
mirror pipe or duct that is used for the transmission of the daylight
from the outside into a building. The lightpipes are usually used in
the daylighting buildings, in the residential, industrial and
commercial sectors. This paper is about the performances of a
lightpipe installed in a laboratory (3 m x 2.6 m x 3 m) without
windows. The aim is to analyse the luminous intensity distribution
for several sky/sun conditions. The lightpipe was monitored during
the year 2006. The lightpipe is 1 m long and the diameter of the top
collector and of the internal diffuser device is 0.25 m. In the
laboratory there are seven illuminance sensors: one external is
located on the roof of the laboratory and six internal sensors are
connected to a data acquisition system. The internal sensors are
positioned under the internal diffusive device at an height of 0.85 m
from the floor to simulate a working plane. The numerical data are
obtained through a simulation software. This paper shows the
comparison between the experimental and numerical results
concerning the behavior of the lightpipe.