Abstract: During an earthquake, a bridge crane may be
subjected to multiple impacts between crane wheels and rail. In order
to model such phenomena, a time-history dynamic analysis with a
multi-scale approach is performed. The high frequency aspect of the
impacts between wheels and rails is taken into account by a Lagrange
explicit event-capturing algorithm based on a velocity-impulse
formulation to resolve contacts and impacts. An implicit temporal
scheme is used for the rest of the structure. The numerical coupling
between the implicit and the explicit schemes is achieved with a
heterogeneous asynchronous time-integrator.
Abstract: We present an integration approach of a CMOS biosensor into a polymer based microfluidic environment suitable for mass production. It consists of a wafer-level-package for the silicon die and laser bonding process promoted by an intermediate hot melt foil to attach the sensor package to the microfluidic chip, without the need for dispensing of glues or underfiller. A very good condition of the sensing area was obtained after introducing a protection layer during packaging. A microfluidic flow cell was fabricated and shown to withstand pressures up to Δp = 780 kPa without leakage. The employed biosensors were electrically characterized in a dry environment.