Abstract: Water vapour transport properties of gypsum block
are studied in dependence on relative humidity using inverse analysis
based on genetic algorithm. The computational inverse analysis is
performed for the relative humidity profiles measured along the
longitudinal axis of a rod sample. Within the performed transient
experiment, the studied sample is exposed to two environments with
different relative humidity, whereas the temperature is kept constant.
For the basic gypsum characterisation and for the assessment of input
material parameters necessary for computational application of
genetic algorithm, the basic material properties of gypsum are
measured as well as its thermal and water vapour storage parameters.
On the basis of application of genetic algorithm, the relative
humidity dependent water vapour diffusion coefficient and water
vapour diffusion resistance factor are calculated.
Abstract: Combined experimental and computational analysis of
hygrothermal performance of an interior thermal insulation system
applied on a brick wall is presented in the paper. In the experimental
part, the functionality of the insulation system is tested at simulated
difference climate conditions using a semi-scale device. The
measured temperature and relative humidity profiles are used for the
calibration of computer code HEMOT that is finally applied for a
long-term hygrothermal analysis of the investigated structure.