Abstract: The purpose of this paper is to contribute to the
enhancement of a hydroelectric plant protection by coordinating
protection measures / existing security and introducing new measures
under a risk management process. In addition, plan identifies key
critical elements of a hydroelectric plant, from its level vulnerabilities
and threats it is subjected to in order to achieve the necessary
protection measures to reduce the level of risk.
Abstract: In order to obtain efficient pollutants removal in
small-scale wastewater treatment plants, uniform water flow has to be
achieved. The experimental setup, designed for treating high-load
wastewater (leachate), consists of two aerobic biological reactors and
a lamellar settler. Both biological tanks were aerated by using three
different types of aeration systems - perforated pipes, membrane air
diffusers and tube ceramic diffusers. The possibility of homogenizing
the water mass with each of the air diffusion systems was evaluated
comparatively. The oxygen concentration was determined by optical
sensors with data logging. The experimental data was analyzed
comparatively for all three different air dispersion systems aiming to
identify the oxygen concentration variation during different
operational conditions. The Oxygenation Capacity was calculated for
each of the three systems and used as performance and selection
parameter. The global mass transfer coefficients were also evaluated
as important tools in designing the aeration system. Even though
using the tubular porous diffusers leads to higher oxygen
concentration compared to the perforated pipe system (which
provides medium-sized bubbles in the aqueous solution), it doesn’t
achieve the threshold limit of 80% oxygen saturation in less than 30
minutes. The study has shown that the optimal solution for the
studied configuration was the radial air diffusers which ensure an
oxygen saturation of 80% in 20 minutes. An increment of the values
was identified when the air flow was increased.
Abstract: This paper presents the results obtained by numerical
simulation using the software ANSYS CFX-CFD for the air
pollutants dispersion in the atmosphere coming from the evacuation
of combustion gases resulting from the fuel combustion in an electric
thermal power plant. The model uses the Navier-Stokes equation to
simulate the dispersion of pollutants in the atmosphere. It is
considered as important factors in elaboration of simulation the
atmospheric conditions (pressure, temperature, wind speed, wind
direction), the exhaust velocity of the combustion gases, chimney
height and the obstacles (buildings). Using the air quality monitoring
stations it is measured the concentrations of main pollutants (SO2,
NOx and PM). The pollutants were monitored over a period of 3
months, after that the average concentration are calculated, which is
used by the software. The concentrations are: 8.915 μg/m3 (NOx),
9.587 μg/m3 (SO2) and 42 μg/m3 (PM). A comparison of test data
with simulation results demonstrated that CFX was able to describe
the dispersion of the pollutant as well the concentration of this
pollutants in the atmosphere.