Design and Fabrication of a Miniaturized Microstrip Antenna Loaded by DNG Metamaterial

In this paper the design, fabrication, and testing of a miniaturized rectangular microstrip patch antenna loaded with DNG metamaterials is reported. The metamaterial is composed of two nested spiral strips and a single straight strip which are etched on two sides of a 5.7 mm×5.7 mm Rogers RT/duroid 5880 with 0.5 mm thickness and dielectric constant of 2.2. Two units of this structure as a double negative (DNG) medium in combination with air as a double positive (DPS) medium are used as substrate of the microstrip patch antenna. By placing these metamaterial structures under the patch, a sub-wavelength resonance occurs which leads to a smaller size patch antenna compared to the conventional antenna at that frequency. The total size of the proposed antenna is reduced 54.6%. The dimensions of the proposed patch antenna are significantly smaller than the wavelength of the operation frequency with respect to the conventional patch antenna. Simulation result and test result for the proposed patch antenna are given and compared.

Assessment of the Adaptive Pushover Analysis Using Displacement-based Loading in Prediction the Seismic Behaviour of the Unsymmetric-Plan Buildings

The recent drive for use of performance-based methodologies in design and assessment of structures in seismic areas has significantly increased the demand for the development of reliable nonlinear inelastic static pushover analysis tools. As a result, the adaptive pushover methods have been developed during the last decade, which unlike their conventional pushover counterparts, feature the ability to account for the effect that higher modes of vibration and progressive stiffness degradation might have on the distribution of seismic storey forces. Even in advanced pushover methods, little attention has been paid to the Unsymmetric structures. This study evaluates the seismic demands for three dimensional Unsymmetric-Plan buildings determined by the Displacement-based Adaptive Pushover (DAP) analysis, which has been introduced by Antoniou and Pinho [2004]. The capability of DAP procedure in capturing the torsional effects due to the irregularities of the structures, is investigated by comparing its estimates to the exact results, obtained from Incremental Dynamic Analysis (IDA). Also the capability of the procedure in prediction the seismic behaviour of the structure is discussed.

Evaluation of the Displacement-Based and the Force-Based Adaptive Pushover Methods in Seismic Response Estimation of Irregular Buildings Considering Torsional Effects

Recent years, adaptive pushover methods have been developed for seismic analysis of structures. Herein, the accuracy of the displacement-based adaptive pushover (DAP) method, which is introduced by Antoniou and Pinho [2004], is evaluated for Irregular buildings. The results are compared to the force-based procedure. Both concrete and steel frame structures, asymmetric in plan and elevation are analyzed and also torsional effects are taking into the account. These analyses are performed using both near fault and far fault records. In order to verify the results, the Incremental Dynamic Analysis (IDA) is performed.