Abstract: The issue of unintentional islanding in PV grid
interconnection still remains as a challenge in grid-connected
photovoltaic (PV) systems. This paper discusses the overview of
popularly used anti-islanding detection methods, practically applied
in PV grid-connected systems. Anti-islanding methods generally can
be classified into four major groups, which include passive methods,
active methods, hybrid methods and communication base methods.
Active methods have been the preferred detection technique over the
years due to very small non-detected zone (NDZ) in small scale
distribution generation. Passive method is comparatively simpler
than active method in terms of circuitry and operations. However, it
suffers from large NDZ that significantly reduces its performance.
Communication base methods inherit the advantages of active and
passive methods with reduced drawbacks. Hybrid method which
evolved from the combination of both active and passive methods
has been proven to achieve accurate anti-islanding detection by many
researchers. For each of the studied anti-islanding methods, the
operation analysis is described while the advantages and
disadvantages are compared and discussed. It is difficult to pinpoint a
generic method for a specific application, because most of the
methods discussed are governed by the nature of application and
system dependent elements. This study concludes that the setup and
operation cost is the vital factor for anti-islanding method selection in
order to achieve minimal compromising between cost and system
quality.
Abstract: Due to the non-linear characteristics of photovoltaic
(PV) array, PV systems typically are equipped with the capability of
maximum power point tracking (MPPT) feature. Moreover, in the
case of PV array under partially shaded conditions, hotspot problem
will occur which could damage the PV cells. Partial shading causes
multiple peaks in the P-V characteristic curves. This paper presents a
hybrid algorithm of Particle Swarm Optimization (PSO) and
Artificial Neural Network (ANN) MPPT algorithm for the detection
of global peak among the multiple peaks in order to extract the true
maximum energy from PV panel. The PV system consists of PV
array, dc-dc boost converter controlled by the proposed MPPT
algorithm and a resistive load. The system was simulated using
MATLAB/Simulink package. The simulation results show that the
proposed algorithm performs well to detect the true global peak
power. The results of the simulations are analyzed and discussed.