Abstract: Most often the contaminants are not taken seriously into consideration, and this behavior comes out directly from the lack of monitoring and professional reporting about pollution in the printing facilities in Serbia. The goal of planned and systematic ozone measurements in ambient air of the screen printing facilities in Novi Sad is to examine of its impact on the employees health, and to track trends in concentration. In this study, ozone concentrations were determined by using discontinuous and continuous method during the automatic and manual screen printing process. Obtained results indicates that the average concentrations of ozone measured during the automatic process were almost 3 to 28 times higher for discontinuous and 10 times higher for continuous method (1.028 ppm) compared to the values prescribed by OSHA. In the manual process, average concentrations of ozone were within prescribed values for discontinuous and almost 3 times higher for continuous method (0.299 ppm).
Abstract: Blood pulse is an important human physiological signal commonly used for the understanding of the individual physical health. Current methods of non-invasive blood pulse sensing require direct contact or access to the human skin. As such, the performances of these devices tend to vary with time and are subjective to human body fluids (e.g. blood, perspiration and skin-oil) and environmental contaminants (e.g. mud, water, etc). This paper proposes a simulation model for the novel method of non-invasive acquisition of blood pulse using the disturbance created by blood flowing through a localized magnetic field. The simulation model geometry represents a blood vessel, a permanent magnet, a magnetic sensor, surrounding tissues and air in 2-dimensional. In this model, the velocity and pressure fields in the blood stream are described based on Navier-Stroke equations and the walls of the blood vessel are assumed to have no-slip condition. The blood assumes a parabolic profile considering a laminar flow for blood in major artery near the skin. And the inlet velocity follows a sinusoidal equation. This will allow the computational software to compute the interactions between the magnetic vector potential generated by the permanent magnet and the magnetic nanoparticles in the blood. These interactions are simulated based on Maxwell equations at the location where the magnetic sensor is placed. The simulated magnetic field at the sensor location is found to assume similar sinusoidal waveform characteristics as the inlet velocity of the blood. The amplitude of the simulated waveforms at the sensor location are compared with physical measurements on human subjects and found to be highly correlated.
Abstract: This paper presents the simulation results of electric field and potential distributions along surface of silicone rubber polymer insulators under clean and various contamination conditions with/without water droplets. Straight sheds insulator having leakage distance 290 mm was used in this study. Two type of contaminants, playwood dust and cement dust, have been studied the effect of contamination on the insulator surface. The objective of this work is to comparison the effect of contamination on potential and electric field distributions along the insulator surface when water droplets exist on the insulator surface. Finite element method (FEM) is adopted for this work. The simulation results show that contaminations have no effect on potential distribution along the insulator surface while electric field distributions are obviously depended on contamination conditions.
Abstract: Sampling and analysis of leachate from Bhalaswa
landfill and groundwater samples from nearby locations, clearly
indicated the likely contamination of groundwater due to landfill
leachate. The results of simulation studies carried out for the
migration of Chloride from landfill shows that the simulation results
are in consonance with the observed concentration of Chloride in the
vicinity of landfill facility. The solid waste disposal system presently
being practiced in Delhi consists of mere dumping of wastes
generated, at three locations Bhalaswa, Ghazipur, and Okhla without
any regard to proper care for the protection of surrounding
environment. Bhalaswa landfill site in Delhi, which is being operated
as a dump site, is expected to become cause of serious groundwater
pollution in its vicinity. The leachate from Bhalaswa landfill was
found to be having a high concentration of chlorides, as well as DOC,
COD. The present study was undertaken to determine the likely
concentrations of principle contaminants in the groundwater over a
period of time due to the discharge of such contaminants from
landfill leachates to the underlying groundwater. The observed
concentration of chlorides in the groundwater within 75m of the
radius of landfill facility was found to be in consonance with the
simulated concentration of chloride in groundwater considering one
dimensional transport model, with finite mass of contaminant source.
Governing equation of contaminant transport involving advection and
diffusion-dispersion was solved in matlab7.0 using finite difference
method.
Abstract: As a result of urbanization, the unpredictable growth of industry and transport, production of chemicals, military activities, etc. the concentration of anthropogenic toxicants spread in nature exceeds all the permissible standards. Most dangerous among these contaminants are organic compounds having great persistence, bioaccumulation, and toxicity along with our awareness of their prominent occurrence in the environment and food chain. Among natural ecological tools, plants still occupying above 40% of the world land, until recently, were considered as organisms having only a limited ecological potential, accumulating in plant biomass and partially volatilizing contaminants of different structure. However, analysis of experimental data of the last two decades revealed the essential role of plants in environment remediation due to ability to carry out intracellular degradation processes leading to partial or complete decomposition of carbon skeleton of different structure contaminants. Though, phytoremediation technologies still are in research and development, their various applications have been successfully used. The paper aims to analyze mechanisms of organic contaminants uptake and detoxification in plants, being the less studied issue in evaluation and exploration of plants potential for environment remediation.
Abstract: Fly ash is a significant waste that is released of
thermal power plants and defined as very fine particles that are drifted upward with up taken by the flue gases due to the burning of
used coal [1]. The fly-ash is capable of removing organic
contaminants in consequence of high carbon content, a large surface area per unit volume and contained heavy metals. Therefore, fly ash
is used as an effective coagulant and adsorbent by pelletization [2, 3].
In this study, the possibility of use of fly ash taken from Turkey like low-cost adsorbent for adsorption of zinc ions found in waste
water was investigated. The fly ash taken from Turkey was pelletized with bentonite and molass to evaluate the adsorption capaticity. For
this purpose; analyses such as sieve analysis, XRD, XRF, FTIR and SEM were performed. As a result, it was seen that pellets prepared
from fly ash, bentonite and molass would be used for zinc adsorption.
Abstract: This research is part of a broad program aimed at
advancing the science and technology involved in the rescue and
rehabilitation of oiled wildlife. One aspect of this research involves
the use of oil-sequestering magnetic particles for the removal of
contaminants from plumage – so-called “magnetic cleansing". This
treatment offers a number of advantages over conventional
detergent-based methods including portability - which offers the
possibility of providing a “quick clean" to the animal upon first
encounter in the field. This could be particularly advantageous
when the contaminant is toxic and/or corrosive and/or where there
is a delay in transporting the victim to a treatment centre. The
method could also be useful as part of a stabilization protocol when
large numbers of affected animals are awaiting treatment. This
presentation describes the design, development and testing of a
prototype field kit for providing a “quick clean" to contaminated
wildlife in the field.
Abstract: The remediation of water resources pollution in
developing countries requires the application of alternative
sustainable cheaper and efficient end-of-pipe wastewater treatment
technologies. The feasibility of use of South African cheap and
abundant pine tree (Pinus patula) sawdust for development of lowcost
AC of comparable quality to expensive commercial ACs in the
abatement of water pollution was investigated. AC was developed at
optimized two-stage N2-superheated steam activation conditions in a
fixed bed reactor, and characterized for proximate and ultimate
properties, N2-BET surface area, pore size distribution, SEM, pHPZC
and FTIR. The sawdust pyrolysis activation energy was evaluated by
TGA. Results indicated that the chars prepared at 800oC and 2hrs
were suitable for development of better quality AC at 800oC and 47%
burn-off having BET surface area (1086m2/g), micropore volume
(0.26cm3/g), and mesopore volume (0.43cm3/g) comparable to
expensive commercial ACs, and suitable for water contaminants
removal. The developed AC showed basic surface functionality at
pHPZC at 10.3, and a phenol adsorption capacity that was higher than
that of commercial Norit (RO 0.8) AC. Thus, it is feasible to develop
better quality low-cost AC from (Pinus patula) sawdust using twostage
N2-steam activation in fixed-bed reactor.
Abstract: Two seperate experiments by barley and alfalfa were
conducted to a 2×8 factorial completely randomised design, with four
replicates. Factors were inoculation (M) with Gomus mosseae or uninoculation
(M0) and seven levels of contaminants (Co, Cd, Pb and
combinations) plus an uncontaminated control treatment (C). Heavy
metals in plant tissues and soil were quantified by Inductively
Coupled Plasma Optical Emission Spectrometer (ICP-OES) (Variant-
Liberty 150AX Turbo). Phytoextraction coefficient of contaminants
calculated by concentration of heavy metals in the shoot (mgkg-1) /
concentration of heavy metals in soil (mgkg-1). In the barley, the
highest rate of phytoextraction coefficient of Pb, Cd and Co was in
M0Pb, M0PbCoCd and MCo, respectively (P
Abstract: Biochemical investigations were carried out to assess
the effect of different exposure regimes of Kazakhstan crude oil
(KCO) on hepatic antioxidant defense system in albino rats.
Contaminants were delivered under two different dosing regimes,
with all treatments receiving the same total contaminant load by the
end of the exposure period. Rats in regime A injected with KCO
once at a dose of 6 ml/kg bw while in regime B injected multiply at a
dose of 1.5 ml/kg bw on day 1, 3, 5 and 8. Antioxidant biomarkers
were measured in hepatic tissue after 1, 3, 5 and 8 days. Significant
induction was observed in serum aminotransferases (ALT, AST)
(p
Abstract: The contamination of 15 ground water resources
of a selected region earmarked for the emergency supply
of population has been monitored. The resources have been selected
on the basis of previous assessment of natural conditions
and the exploitation of territory in their surroundings and infiltration
area. Two resources out of 15 have been excluded from further
exploitation, because they have not met some of the 72 assessed
hygienic indicators of extended analysis. The remaining 13 resources
have been the subject of health risk analysis in relation
to the contamination by arsenic, lead, cadmium, mercury, nickel and
manganese. The risk analysis proved that all 13 resources meet
health standards with regard to the above mentioned purposefully
selected elements and may thus be included into crisis plans. Water
quality of ground resources may be assessed in the same way
with regard to other contaminants.
Abstract: Soil organic carbon (SOC) plays a key role in soil
fertility, hydrology, contaminants control and acts as a sink or source
of terrestrial carbon content that can affect the concentration of
atmospheric CO2. SOC supports the sustainability and quality of
ecosystems, especially in semi-arid region. This study was
conducted to determine relative importance of 13 different
exploratory climatic, soil and geometric factors on the SOC contents
in one of the semiarid watershed zones in Iran. Two methods
canonical discriminate analysis (CDA) and feed-forward back
propagation neural networks were used to predict SOC. Stepwise
regression and sensitivity analysis were performed to identify
relative importance of exploratory variables. Results from sensitivity
analysis showed that 7-2-1 neural networks and 5 inputs in CDA
models output have highest predictive ability that explains %70 and
%65 of SOC variability. Since neural network models outperformed
CDA model, it should be preferred for estimating SOC.
Abstract: Hydraulic conductivity is one parameter important for predicting the movement of water and contaminants dissolved in the water through the soil. The hydraulic conductivity is measured on soil samples in the lab and sometimes tests carried out in the field. The hydraulic conductivity has been related to soil particle diameter by a number of investigators. In this study, 25 set of soil samples with sand texture. The results show approximately success in predicting hydraulic conductivity from particle diameters data. The following relationship obtained from multiple linear regressions on data (R2 = 0.52): Where d10, d50 and d60, are the soil particle diameter (mm) that 10%, 50% and 60% of all soil particles are finer (smaller) by weight and Ks, saturated hydraulic conductivity is expressed in m/day. The results of regression analysis showed that d10 play a more significant role with respect to Ks, saturated hydraulic conductivity (m/day), and has been named as the effective parameter in Ks calculation.
Abstract: The modified Claus process is commonly used in oil
refining and gas processing to recover sulfur and destroy
contaminants formed in upstream processing. A Claus furnace feed
containing a relatively low concentration of H2S may be incapable of
producing a stable flame. Also, incomplete combustion of
hydrocarbons in the feed can lead to deterioration of the catalyst in
the reactors due to soot or carbon deposition. Therefore, special
consideration is necessary to achieve the appropriate overall sulfur
recovery. In this paper, some configurations available to treat lean
acid gas streams are described and the most appropriate ones are
studied to overcome low H2S concentration problems. As a result,
overall sulfur recovery is investigated for feed preheating and hot gas
configurations.
Abstract: Modern Society is strongly dependent on a reliable
power supply. The availability of cheap and reliable supply of
electrical energy is an indicator of societal welfare. Uninterrupted
reliable operation of a modern power system depends to a great
extent on reliable and satisfactory performance of insulators under
different environmental conditions. This paper reports result of
natural pollution tests that have been done at sites around city of
Aligarh (India). Flashover voltage per insulation distance (FOVUID)
of porcelain disc insulator for different pH values, ESDD has been
recorded for proper correlation between electrical and chemical
parameters. The pH of the contaminants has been suggested to be an
effective pollution severity indicator and may be used as a diagnostic
parameter for proper maintenance of porcelain insulators.
Abstract: The objective of this study was to evaluate the
distribution patterns of Cd, Zn and Hg in groundwater by geospatial
interpolation. The study was performed at Rayong province in the
eastern part of Thailand, with high agricultural and industrial
activities. Groundwater samples were collected twice a year from 31
tubewells around this area. Inductively Coupled Plasma-Atomic
Emission Spectrometer (ICP-AES) was used to measure the
concentrations of Cd, Zn, and Hg in groundwater samples. The
results demonstrated that concentrations of Cd, Zn and Hg range
from 0.000-0.297 mg/L (x = 0.021±0.033 mg/L), 0.022-33.236 mg/L
(x = 4.214±4.766 mg/L) and 0.000-0.289 mg/L (x = 0.023±0.034
mg/L), respectively. Most of the heavy metals concentrations were
exceeded groundwater quality standards as specified in the Ministry
of Natural Resources and Environment, Thailand. The trend
distribution of heavy metals were high concentrations at the
southeastern part of the area that especially vulnerable to heavy
metals and other contaminants.
Abstract: In this study, the designed dual stage membrane
bioreactor (MBR) system was conceptualized for the treatment of
cyanide and heavy metals in electroplating wastewater. The design
consisted of a primary treatment stage to reduce the impact of
fluctuations and the secondary treatment stage to remove the residual
cyanide and heavy metal contaminants in the wastewater under
alkaline pH conditions. The primary treatment stage contained
hydrolyzed Citrus sinensis (C. sinensis) pomace and the secondary
treatment stage contained active Aspergillus awamori (A. awamori)
biomass, supplemented solely with C. sinensis pomace extract from
the hydrolysis process. An average of 76.37%, 95.37%, 93.26 and
94.76% and 99.55%, 99.91%, 99.92% and 99.92% degradation
efficiency for total cyanide (T-CN), including the sorption of nickel
(Ni), zinc (Zn) and copper (Cu) were observed after the first and
second treatment stages, respectively. Furthermore, cyanide
conversion by-products degradation was 99.81% and 99.75 for both
formate (CHOO-) and ammonium (NH4
+) after the second treatment
stage. After the first, second and third regeneration cycles of the C.
sinensis pomace in the first treatment stage, Ni, Zn and Cu removal
achieved was 99.13%, 99.12% and 99.04% (first regeneration cycle),
98.94%, 98.92% and 98.41% (second regeneration cycle) and 98.46
%, 98.44% and 97.91% (third regeneration cycle), respectively.
There was relatively insignificant standard deviation detected in all
the measured parameters in the system which indicated
reproducibility of the remediation efficiency in this continuous
system.
Abstract: The contents of nitrates and nitrites were monitored in
15 ground water resources of a selected region earmarked for the
emergency supply of population. The resources have been selected on
the basis of previous assessment of natural conditions and the
exploitation of territory in the infiltration area as well as the
surroundings of water resources. The health risk analysis carried out
in relation to nitrates and nitrites, which were found to be the most
serious water contaminants, proved, that 14 resources met the health
standards in relation to the assessed criterion and could be included in
crisis plans. Water quality of ground resources may be assessed in the
same way with regard to other contaminants.
Abstract: Dynamic characteristics of a four-lobe journal bearing
of micropolar fluids are presented. Lubricating oil containing
additives and contaminants is modelled as micropolar fluid. The
modified Reynolds equation is obtained using the micropolar
lubrication theory and solving it by using finite difference technique.
The dynamic characteristics in terms of stiffness, damping
coefficients, the critical mass and whirl ratio are determined for
various values of size of material characteristic length and the
coupling number. The results show compared with Newtonian fluids,
that micropolar fluid exhibits better stability.