Abstract: Most often the contaminants are not taken seriously into consideration, and this behavior comes out directly from the lack of monitoring and professional reporting about pollution in the printing facilities in Serbia. The goal of planned and systematic ozone measurements in ambient air of the screen printing facilities in Novi Sad is to examine of its impact on the employees health, and to track trends in concentration. In this study, ozone concentrations were determined by using discontinuous and continuous method during the automatic and manual screen printing process. Obtained results indicates that the average concentrations of ozone measured during the automatic process were almost 3 to 28 times higher for discontinuous and 10 times higher for continuous method (1.028 ppm) compared to the values prescribed by OSHA. In the manual process, average concentrations of ozone were within prescribed values for discontinuous and almost 3 times higher for continuous method (0.299 ppm).
Abstract: This paper presents the study of parameters affecting
the environment protection in the printing industry. The paper has
also compared LCA studies performed within the printing industry in
order to identify common practices, limitations, areas for
improvement, and opportunities for standardization. This comparison
is focused on the data sources and methodologies used in the printing
pollutants register. The presented concepts, methodology and results
represent the contribution to the sustainable development
management. Furthermore, the paper analyzes the result of the
quantitative identification of hazardous substances emitted in printing
industry of Novi Sad.