Abstract: In this paper, natural convection in an attic is numerically investigated. The geometry of the problem is considered to be a triangular enclosure. ANSYS Fluent software is used for modeling and numerical solution. This study is for steady state. Four right-angled triangles with height to base ratios of 2, 1, 0.5 and 0.25 are considered. The behavior of various parameters related to its performance, including temperature distribution and velocity vectors are evaluated, and graphs for the Nusselt number have been drawn. Also, in this study, the effect of geometric shape of enclosure with different height-to-base ratios has been evaluated for three types of boundary conditions of winter, summer day and one another state. It can be concluded that as the bottom side temperature and ratio of base to height of the enclosure increases, the convective effects become more prominent and circulation happened.
Abstract: Higher capacities of power plants together with
increased awareness on environmental considerations have led to
taller height of stacks. It is seen that strong wind can result in falling
of stacks. So, aerodynamic consideration of stacks is very important
in order to save the falling of stacks. One stack is not enough in
industries and power sectors and two or three stacks are required for
proper operation of the unit. It is very important to arrange the stacks
in proper way to resist their downfall. The present experimental
study concentrates on the mutual effect of three nearby stacks on
each other at three different arrangements, viz. linear, side-by-side
and triangular. The experiments find out the directions of resultant
forces acting on the stacks in different configurations so that proper
arrangement of supports can be made with respect to the wind
directionality obtained from local meteorological data. One can also
easily ascertain which stack is more vulnerable to wind in
comparison to the others for a particular configuration. Thus, this
study is important in studying the effect of wind force on three stacks
in different arrangements and is very helpful in placing the supports
in proper places in order to avoid failing of stack-like structures due
to wind.