Abstract: Characterizing the network flow is of fundamental importance to understand the complex dynamics of networks. And passenger flow characteristics of the subway network are very relevant for an effective transportation management in urban cities. In this study, passenger flow of Seoul metropolitan subway network is investigated and characterized through statistical analysis. Traditional betweenness centrality measure considers only topological structure of the network and ignores the transportation factors. This paper proposes a weighted betweenness centrality measure that incorporates monthly passenger flow volume. We apply the proposed measure on the Seoul metropolitan subway network involving 493 stations and 16 lines. Several interesting insights about the network are derived from the new measures. Using Kolmogorov-Smirnov test, we also find out that monthly passenger flow between any two stations follows a power-law distribution and other traffic characteristics such as congestion level and throughflow traffic follow exponential distribution.
Abstract: The problem of thermal convection in temperature and
magnetic field sensitive Newtonian ferromagnetic liquid is studied
in the presence of uniform vertical magnetic field and throughflow.
Using a combination of Galerkin and shooting techniques the critical
eigenvalues are obtained for stationary mode. The effect of Prandtl
number (Pr > 1) on onset is insignificant and nonlinearity of
non-buoyancy magnetic parameter M3 is found to have no influence
on the onset of ferroconvection. The magnetic buoyancy number, M1
and variable viscosity parameter, V have destabilizing influences on
the system. The effect of throughflow Peclet number, Pe is to delay
the onset of ferroconvection and this effect is independent of the
direction of flow.
Abstract: Linear stability analysis of double diffusive convection
in a horizontal porous layer saturated with fluid is examined by
considering the effects of viscous dissipation, concentration based
internal heat source and vertical throughflow. The basic steady
state solution for Governing equations is derived. Linear stability
analysis has been implemented numerically by using shooting
and Runge-kutta methods. Critical thermal Rayleigh number Rac
is obtained for various values of solutal Rayleigh number Sa,
vertical Peclet number Pe, Gebhart number Ge, Lewis number
Le and measure of concentration based internal heat source
γ. It is observed that Ge has destabilizing effect for upward
throughflow and stabilizing effect for downward throughflow. And
γ has considerable destabilizing effect for upward throughflow and
insignificant destabilizing effect for downward throughflow.