Abstract: When assessing the quality of the spraying procedure, three indicators are used: uneven distribution of precipitation of liquid sprayed, degree of coverage of sprayed surfaces, and deposition of liquid spraying However, there is a lack of information on the relationship between the quality parameters of the procedure. Therefore, the research was carried out at the Institute of Agricultural Engineering of Wrocław University of Environmental and Life Sciences. The aim of the study was to determine the relationship between the degree of coverage of sprayed surfaces and the deposition of liquid in the aspect of the parametric characteristics of the protected plant using selected single and double stream nozzles. Experiments were conducted under laboratory conditions. The carrier of nozzles acted as an independent self-propelled sprayer used for spraying, whereas the parametric characteristics of plants were determined using artificial plants as the ratio of the vertical projection surface and the horizontal projection surface. The results and their analysis showed a strong and very strong correlation between the analyzed parameters in terms of the characteristics of the sprayed object.
Abstract: Gas condensing units with inner tubes heat exchangers represent third generation technology and differ from second generation heat and mass transfer units, which are fulfilled by passive filling material layer. The first one improves heat and mass transfer by increasing cooled contact surface of gas and condensate drops and film formed in inner tubes heat exchanger. This paper presents a selection of significant factors which influence the heat and mass transfer. Experimental planning is based on the research and analysis of main three independent variables; velocity of water and gas as well as density of spraying. Empirical mathematical models show that the coefficient of heat transfer is used as dependent parameter which depends on two independent variables; water and gas velocity. Empirical model is proved by the use of experimental data of two independent gas condensing units in Lithuania and Russia. Experimental data are processed by the use of heat transfer criteria-Kirpichov number. Results allow drawing the graphical nomogram for the calculation of heat and mass transfer conditions in the innovative and energy efficient gas cooling unit.
Abstract: This work contributes a statistical model and simulation
framework yielding the best estimate possible for the potential
herbicide reduction when using the MoDiCoVi algorithm all the
while requiring a efficacy comparable to conventional spraying. In
June 2013 a maize field located in Denmark were seeded. The field
was divided into parcels which was assigned to one of two main
groups: 1) Control, consisting of subgroups of no spray and full dose
spraty; 2) MoDiCoVi algorithm subdivided into five different leaf
cover thresholds for spray activation. In addition approximately 25%
of the parcels were seeded with additional weeds perpendicular to
the maize rows. In total 299 parcels were randomly assigned with
the 28 different treatment combinations. In the statistical analysis,
bootstrapping was used for balancing the number of replicates. The
achieved potential herbicide savings was found to be 70% to 95%
depending on the initial weed coverage. However additional field
trials covering more seasons and locations are needed to verify
the generalisation of these results. There is a potential for further
herbicide savings as the time interval between the first and second
spraying session was not long enough for the weeds to turn yellow,
instead they only stagnated in growth.
Abstract: In this article, using finite element analysis (FEA)
and an X-ray diffractometer (XRD), cold-sprayed titanium particles
on a steel substrate is investigated in term of cooling time and the
development of residual strains. Three cooling-down models of
sprayed particles after deposition stage are simulated and discussed:
the first model (m1) considers conduction effect to the substrate only,
the second model (m2) considers both conduction as well as
convection effect to the environment, and the third model (m3) which
is the same as the second model but with the substrate heated to a
near particle temperature before spraying. Thereafter, residual strains
developed in the third model is compared with the experimental
measurement of residual strains, which involved a Bruker D8
Advance Diffractometer using CuKa radiation (40kV, 40mA)
monochromatised with a graphite sample monochromator. For
deposition conditions of this study, a good correlation was found to
exist between the FEA results and XRD measurements of residual
strains.