Abstract: The psychological and physical trauma associated with the loss of a human limb can severely impact on the quality of life of an amputee rendering even the most basic of tasks very difficult. A prosthetic device can be of great benefit to the amputee in the performance of everyday human tasks. This paper outlines a proposed mechanical design of a 12 degree-of-freedom SMA actuated artificial hand. It is proposed that the SMA wires be embedded intrinsically within the hand structure which will allow for significant flexibility for use either as a prosthetic hand solution, or as part of a complete lower arm prosthetic solution. A modular approach is taken in the design facilitating ease of manufacture and assembly, and more importantly, also allows the end user to easily replace SMA wires in the event of failure. A biomimetric approach has been taken during the design process meaning that the artificial hand should replicate that of a human hand as far as is possible with due regard to functional requirements. The proposed design has been exposed to appropriate loading through the use of finite element analysis (FEA) to ensure that it is structurally sound. Theoretical analysis of the mechanical framework was also carried out to establish the limits of the angular displacement and velocity of the finger tip as well finger tip force generation. A combination of various polymers and Titanium, which are suitably lightweight, are proposed for the manufacture of the design.
Abstract: Speckle noise affects all coherent imaging systems
including medical ultrasound. In medical images, noise suppression
is a particularly delicate and difficult task. A tradeoff between noise
reduction and the preservation of actual image features has to be made
in a way that enhances the diagnostically relevant image content.
Even though wavelets have been extensively used for denoising
speckle images, we have found that denoising using contourlets gives
much better performance in terms of SNR, PSNR, MSE, variance and
correlation coefficient. The objective of the paper is to determine the
number of levels of Laplacian pyramidal decomposition, the number
of directional decompositions to perform on each pyramidal level and
thresholding schemes which yields optimal despeckling of medical
ultrasound images, in particular. The proposed method consists of the
log transformed original ultrasound image being subjected to contourlet
transform, to obtain contourlet coefficients. The transformed
image is denoised by applying thresholding techniques on individual
band pass sub bands using a Bayes shrinkage rule. We quantify the
achieved performance improvement.
Abstract: Various sounds generated in the chest are included in
auscultation sound. Adaptive Noise Canceller (ANC) is one of the
useful techniques for biomedical signal. But the ANC is not suitable
for auscultation sound. Because the ANC needs two input channels as
a primary signal and a reference signals, but a stethoscope can
provide just one input sound. Therefore, in this paper, it was
proposed the Single Input ANC (SIANC) for suppression of breath
sound in a cardiac auscultation sound. For the SIANC, it was
proposed that the reference generation system which included Heart
Sound Detector, Control and Reference Generator. By experiment
and comparison, it was confirmed that the proposed SIANC was
efficient for heart sound enhancement and it was independent of
variations of a heartbeat.
Abstract: The need of high frame-rate imaging has been triggered by the new applications of ultrasound imaging to transient elastography and real-time 3D ultrasound. Using plane wave excitation (PWE) is one of the methods to achieve very high frame-rate imaging since an image can be formed with a single insonification. However, due to the lack of transmit focusing, the image quality with PWE is lower compared with those using conventional focused transmission. To solve this problem, we propose a filter-retrieved transmit focusing (FRF) technique combined with cross-correlation weighting (FRF+CC weighting) for high frame-rate imaging with PWE. A restrospective focusing filter is designed to simultaneously minimize the predefined sidelobe energy associated with single PWE and the filter energy related to the signal-to-noise-ratio (SNR). This filter attempts to maintain the mainlobe signals and to reduce the sidelobe ones, which gives similar mainlobe signals and different sidelobes between the original PWE and the FRF baseband data. Normalized cross-correlation coefficient at zero lag is calculated to quantify the degree of similarity at each imaging point and used as a weighting matrix to the FRF baseband data to further suppress sidelobes, thus improving the filter-retrieved focusing quality.
Abstract: One problem of synthetic sunflower cultivation is an
erratic germination of the seeds. To improve the germination, presowing
seed treatment with an ultrasound was tested. All treatments
were carried out at 40 kHz frequency with the intensities of 40, 60,
80 and 100% of the ultrasonic generator total power (250 W) for the
durations of 5, 10, 15 and 20 minutes. Data on seed germination
percentage, seed vigor index (SVI), root and shoot lengths of
seedlings were collected. The results showed that germination, SVI,
root and shoot lengths of ultrasonic treated seedlings were different
from the control, depending on intensity of the ultrasound. The
effects of ultrasonic treatment were significant on germination,
resulting in a maximum increase of 43% at 40 and 60% intensities
compared to that of the control seeds. In addition, seedlings of these 2
treatments had higher SVI and longer root and shoot lengths than that
of the control seedlings. All treatment durations resulted in higher
germination and SVI, longer root and higher shoot lenghts of
seedlings than the control. Among the duration treatments, only SVI
and seedling root length were significantly different.
Abstract: Artificial Neural Network (ANN) has been
extensively used for classification of heart sounds for its
discriminative training ability and easy implementation. However, it
suffers from overparameterization if the number of nodes is not
chosen properly. In such cases, when the dataset has redundancy
within it, ANN is trained along with this redundant information that
results in poor validation. Also a larger network means more
computational expense resulting more hardware and time related
cost. Therefore, an optimum design of neural network is needed
towards real-time detection of pathological patterns, if any from heart
sound signal. The aims of this work are to (i) select a set of input
features that are effective for identification of heart sound signals and
(ii) make certain optimum selection of nodes in the hidden layer for a
more effective ANN structure. Here, we present an optimization
technique that involves Singular Value Decomposition (SVD) and
QR factorization with column pivoting (QRcp) methodology to
optimize empirically chosen over-parameterized ANN structure.
Input nodes present in ANN structure is optimized by SVD followed
by QRcp while only SVD is required to prune undesirable hidden
nodes. The result is presented for classifying 12 common
pathological cases and normal heart sound.