Abstract: In this paper, the vessel inscribed trigonometry (VITM) for the vessel progression orientation (VPO) is proposed in the two-dimensional fundus image. The VPO is a major factor in the optic disc (OD) detection which is a basic process in the retina analysis. To measure the VPO, skeletons of vessel are used. First, the vessels are classified into three classes as vessel end, vessel branch and vessel stem. And the chain code maps of VS are generated. Next, two farthest neighborhoods of each point on VS are searched by the proposed angle restriction. Lastly, a gradient of the straight line between two farthest neighborhoods is estimated to measure the VPO. VITM is validated by comparing with manual results and 2D Gaussian templates. It is confirmed that VPO of the proposed mensuration is correct enough to detect OD from the results of experiment which applied VITM to detect OD in fundus images.
Abstract: Various sounds generated in the chest are included in
auscultation sound. Adaptive Noise Canceller (ANC) is one of the
useful techniques for biomedical signal. But the ANC is not suitable
for auscultation sound. Because the ANC needs two input channels as
a primary signal and a reference signals, but a stethoscope can
provide just one input sound. Therefore, in this paper, it was
proposed the Single Input ANC (SIANC) for suppression of breath
sound in a cardiac auscultation sound. For the SIANC, it was
proposed that the reference generation system which included Heart
Sound Detector, Control and Reference Generator. By experiment
and comparison, it was confirmed that the proposed SIANC was
efficient for heart sound enhancement and it was independent of
variations of a heartbeat.