Abstract: To understand the seismic behavior of the offshore
structures, the dynamic interaction of the water-structure-soil should
be assessed. In this regard the role of the water dynamic properties in
magnifying or reducing of the effects of earthquake induced motions
on offshore structures haven't been investigated in precise manner in
available literature. In this paper the sea water level fluctuations
effects on the seismic behavior of a sample of offshore structures has
been investigated by emphasizing on the water-structure interaction
phenomenon. For this purpose a two dimensional finite element
model of offshore structures as well as surrounded water has been
developed using ANSYS software. The effect of soil interaction with
embedded pile foundation has been imposed by using a series of
nonlinear springs in horizontal and vertical directions in soil-piles
contact points. In the model, the earthquake induced motions have
been applied on springs and consequently the motions propagated
upward to the structure and surrounded water. As a result of
numerical study, the horizontal deformations of the offshore deck as
well as internal force and buckling coefficient in structural elements
have been recorded and controlled with and without water presence.
In part of study a parametric study has been accomplished on sea
water level fluctuations and effect of this parameter has been studied
on the aforementioned numerical results.
Abstract: Because of architectural condition and structure application, sometimes mass source and stiffness source are not coincidence, and the structure is irregular. The structure is also might be asymmetric as an asymmetric bracing in plan which leads to unbalance distribution of stiffness or because of unbalance distribution of the mass. Both condition lead to eccentricity and torsion in the structure. The deficiency of ordinary code to evaluate the performance of steel structures against earthquake has been caused designing based on performance level or capacity spectrum be used. By using the mentioned methods it is possible to design a structure that its behavior against different earthquakes be predictive. In this article 5- story buildings with different percentage of asymmetric which is because of stiffness changes and kind of bracing (x and chevron bracing) have been designed. The static and dynamic nonlinear analysis under three acceleration recording has been done. Finally performance level of the structure has been evaluated.
Abstract: The present report describes the characteristics of
damages and behavior of reinforced concrete buildings during the
tsunami action. The discussion is based on the field damage survey in
selected cities located on the coast of the zone affected by the Great
East Japan Earthquake on March 11, 2011. This earthquake is the most
powerful know earthquake that has hit Japan with a magnitude 9.0 and
with epicenter located at 129 km of Sendai city (off the coast). The
earthquake triggered a destructive tsunami with run up height of up to
40 meters that mainly affect cities located on the Pacific Ocean coast of
the Tohoku region (north-east region of Japan). Reinforced concrete
buildings in general resist the tsunami without collapse however the
non-structural elements like panels and ceilings were severely
damaged. The analysis of damages has permitted to understand the
behavior of RC buildings under tsunami attack, and has also permitted
to establish recommendations for their use to take refuge from tsunami
in places where natural topography makes impossible to reach hilltops
or other safer places.
Abstract: A different concept for designing and detailing of
reinforced concrete precast frame structures is analyzed in this paper.
The new detailing of the joints derives from the special hybrid
moment frame joints. The special reinforcements of this alternative
detailing, named modified special hybrid joint, are bondless with
respect to both column and beams. Full scale tests were performed on
a plan model, which represents a part of 5 story structure, cropped in
the middle of the beams and columns spans. Theoretical approach
was developed, based on testing results on twice repaired model,
subjected to lateral seismic type loading. Discussion regarding the
modified special hybrid joint behavior and further on widening
research needed concludes the presentation.
Abstract: For Seismic design, it is important to estimate,
maximum lateral displacement (inelastic displacement) of the
structures due to sever earthquakes for several reasons. Seismic
design provisions estimate the maximum roof and storey drifts
occurring in major earthquakes by amplifying the drifts of the
structures obtained by elastic analysis subjected to seismic design
load, with a coefficient named “displacement amplification factor"
which is greater than one. Here, this coefficient depends on various
parameters, such as ductility and overstrength factors. The present
research aims to evaluate the value of the displacement amplification
factor in seismic design codes and then tries to propose a value to
estimate the maximum lateral structural displacement from sever
earthquakes, without using non-linear analysis. In seismic codes,
since the displacement amplification is related to “force reduction
factor" hence; this aspect has been accepted in the current study.
Meanwhile, two methodologies are applied to evaluate the value of
displacement amplification factor and its relation with the force
reduction factor. In the first methodology, which is applied for all
structures, the ratio of displacement amplification and force reduction
factors is determined directly. Whereas, in the second methodology
that is applicable just for R/C moment resisting frame, the ratio is
obtained by calculating both factors, separately. The acquired results
of these methodologies are alike and estimate the ratio of two factors
from 1 to 1.2. The results indicate that the ratio of the displacement
amplification factor and the force reduction factor differs to those
proposed by seismic provisions such as NEHRP, IBC and Iranian
seismic code (standard no. 2800).
Abstract: Small-scale RC models of both piles and tunnel ducts
were produced as mockups of reality and loaded under soil
confinement conditionsto investigate the damage evolution of
structural RC interacting with soil. Experimental verifications usinga
3D nonlinear FE analysis program called COM3D, which was
developed at the University of Tokyo, are introduced. This analysis
has been used in practice for seismic performance assessment of
underground ducts and in-ground LNG storage tanks in consideration
of soil-structure interactionunder static and dynamic loading. Varying
modes of failure of RCpilessubjected to different magnitudes of soil
confinement were successfully reproduced in the proposed small-scale
experiments and numerically simulated as well. Analytical simulation
was applied to RC tunnel mockups under a wide variety of depth and
soil confinement conditions, and reasonable matching was confirmed.
Abstract: The seismic response of steel shear wall system considering nonlinearity effects using finite element method is investigated in this paper. The non-linear finite element analysis has potential as usable and reliable means for analyzing of civil structures with the availability of computer technology. In this research the large displacements and materially nonlinear behavior of shear wall is presented with developing of finite element code. A numerical model based on the finite element method for the seismic analysis of shear wall is presented with developing of finite element code in this research. To develop the finite element code, the standard Galerkin weighted residual formulation is used. Two-dimensional plane stress model and total Lagrangian formulation was carried out to present the shear wall response and the Newton-Raphson method is applied for the solution of nonlinear transient equations. The presented model in this paper can be developed for analysis of civil engineering structures with different material behavior and complicated geometry.
Abstract: In this paper we describe the design and implementation of a parallel algorithm for data assimilation with ensemble Kalman filter (EnKF) for oil reservoir history matching problem. The use of large number of observations from time-lapse seismic leads to a large turnaround time for the analysis step, in addition to the time consuming simulations of the realizations. For efficient parallelization it is important to consider parallel computation at the analysis step. Our experiments show that parallelization of the analysis step in addition to the forecast step has good scalability, exploiting the same set of resources with some additional efforts.
Abstract: This paper emphasizes on the application of genetic algorithm (GA) to optimize the parameters of the TMD for achieving the best results in the reduction of the building response under earthquake excitations. The Integral of the Time multiplied Absolute value of the Error (ITAE) based on relative displacement of all floors in the building is taken as a performance index of the optimization criterion. The problem of robustly TMD controller design is formatted as an optimization problem based on the ITAE performance index to be solved using GA that has a story ability to find the most optimistic results. An 11–story realistic building, located in the city of Rasht, Iran is considered as a test system to demonstrate effectiveness of the proposed GA based TMD (GATMD) controller without specifying which mode should be controlled. The results of the proposed GATMD controller are compared with the uncontrolled structure through timedomain simulation and some performance indices. The results analysis reveals that the designed GA based TMD controller has an excellent capability in reduction of the seismically excited example building and the ITAE performance, that is so for remains as unknown, can be introduced a new criteria - method for structural dynamic design.
Abstract: Buildings with floating column are highly undesirable built in seismically active areas. Many urban multi-storey buildings today have floating column buildings which are adopted to accommodate parking at ground floor or reception lobbies in the first storey. The earthquake forces developed at different floor levels in a building need to be brought down along the height to the ground by the shortest path; any deviation or discontinuity in this load transfer path results in poor performance of the building. Floating column buildings are severely damaged during earthquake. Damage on this structure can be reduce by taking the effect of infill wall. This paper presents the effect of stiffness of infill wall to the damage occurred in floating column building when ground shakes. Modelling and analysis are carried out by non linear analysis programme IDARC-2D. Damage occurred in beams, columns, storey are studied by formulating modified Park & Ang model to evaluate damage indices. Overall structural damage indices in buildings due to shaking of ground are also obtained. Dynamic response parameters i.e. lateral floor displacement, storey drift, time period, base shear of buildings are obtained and results are compared with the ordinary moment resisting frame buildings. Formation of cracks, yield, plastic hinge, are also observed during analysis.
Abstract: Recently, analysis and designing of the structures
based on the Reliability theory have been the center of attention.
Reason of this attention is the existence of the natural and random
structural parameters such as the material specification, external
loads, geometric dimensions etc. By means of the Reliability theory,
uncertainties resulted from the statistical nature of the structural
parameters can be changed into the mathematical equations and the
safety and operational considerations can be considered in the
designing process. According to this theory, it is possible to study the
destruction probability of not only a specific element but also the
entire system. Therefore, after being assured of safety of every
element, their reciprocal effects on the safety of the entire system can
be investigated.
Abstract: This paper describes the development of a numerical finite element algorithm used for the analysis of reinforced concrete structure equipped with shakes energy absorbing device subjected to earthquake excitation. For this purpose a finite element program code for analysis of reinforced concrete frame buildings is developed. The performance of developed program code is evaluated by analyzing of a reinforced concrete frame buildings model. The results are show that using damper device as seismic energy dissipation system effectively can reduce the structural response of framed structure during earthquake occurrence.
Abstract: The seismic feedback experiences in Algeria have
shown higher percentage of damages for non-code conforming
reinforced concrete (RC) buildings. Furthermore, the vulnerability of
these buildings was further aggravated due to presence of many
factors (e.g. weak the seismic capacity of these buildings, shorts
columns, Pounding effect, etc.).
Consequently Seismic risk assessments were carried out on
populations of buildings to identify the buildings most likely to
undergo losses during an earthquake. The results of such studies are
important in the mitigation of losses under future seismic events as
they allow strengthening intervention and disaster management plans
to be drawn up.
Within this paper, the state of the existing structures is assessed using
"the vulnerability index" method. This method allows the
classification of RC constructions taking into account both, structural
and non structural parameters, considered to be ones of the main
parameters governing the vulnerability of the structure. Based on
seismic feedback from past earthquakes DPM (damage probability
matrices) were developed too.
Abstract: Presented herein is an assessment of current nonlinear
static procedures (NSPs) for seismic evaluation of bucklingrestrained
braced frames (BRBFs) which have become a favorable
lateral-force resisting system for earthquake resistant buildings. The
bias and accuracy of modal, improved modal pushover analysis
(MPA, IMPA) and mass proportional pushover (MPP) procedures
are comparatively investigated when they are applied to BRBF
buildings subjected to two sets of strong ground motions. The
assessment is based on a comparison of seismic displacement
demands such as target roof displacements, peak floor/roof
displacements and inter-story drifts. The NSP estimates are compared
to 'exact' results from nonlinear response history analysis (NLRHA).
The response statistics presented show that the MPP
procedure tends to significantly overestimate seismic demands of
lower stories of tall buildings considered in this study while MPA
and IMPA procedures provide reasonably accurate results in
estimating maximum inter-story drift over all stories of studied BRBF
systems.
Abstract: The results show that the bridge equipped with seismic isolation bearing system shows a high amount of energy dissipation. The purpose of the present study is to analyze the overall performance of continuous curved highway viaducts with different bearing supports, with an emphasis on the effectiveness of seismic isolation based on lead rubber bearing and hedge reaction force bearing system consisted of friction sliding bearing and rubber bearing. The bridge seismic performance has been evaluated on six different cases with six bearing models. The effects of the different arrangement of bearing on the deck superstructure displacements, the seismic damage at the bottom of the piers, movement track at the pier-s top and the total and strain energies absorbed by the structure are evaluated. In conclusion, the results provide sufficient evidence of the effectiveness on the use of seismic isolation on steel curved highway bridges.
Abstract: During last decades, worldwide researchers dedicated
efforts to develop machine-based seismic Early Warning systems,
aiming at reducing the huge human losses and economic damages.
The elaboration time of seismic waveforms is to be reduced in order
to increase the time interval available for the activation of safety
measures. This paper suggests a Data Mining model able to correctly
and quickly estimate dangerousness of the running seismic event.
Several thousand seismic recordings of Japanese and Italian
earthquakes were analyzed and a model was obtained by means of a
Bayesian Network (BN), which was tested just over the first
recordings of seismic events in order to reduce the decision time and
the test results were very satisfactory.
The model was integrated within an Early Warning System
prototype able to collect and elaborate data from a seismic sensor
network, estimate the dangerousness of the running earthquake and
take the decision of activating the warning promptly.
Abstract: The automatic discrimination of seismic signals is an important practical goal for earth-science observatories due to the large amount of information that they receive continuously. An essential discrimination task is to allocate the incoming signal to a group associated with the kind of physical phenomena producing it. In this paper, two classes of seismic signals recorded routinely in geophysical laboratory of the National Center for Scientific and Technical Research in Morocco are considered. They correspond to signals associated to local earthquakes and chemical explosions. The approach adopted for the development of an automatic discrimination system is a modular system composed by three blocs: 1) Representation, 2) Dimensionality reduction and 3) Classification. The originality of our work consists in the use of a new wavelet called "modified Mexican hat wavelet" in the representation stage. For the dimensionality reduction, we propose a new algorithm based on the random projection and the principal component analysis.
Abstract: In this experimental investigation shake table tests
were conducted on two reduced models that represent normal single
room building constructed by Compressed Stabilized Earth Block
(CSEB) from locally available soil. One model was constructed with
earthquake resisting features (EQRF) having sill band, lintel band and
vertical bands to control the building vibration and another one was
without Earthquake Resisting Features. To examine the seismic
capacity of the models particularly when it is subjected to long-period
ground motion by large amplitude by many cycles of repeated
loading, the test specimen was shaken repeatedly until the failure.
The test results from Hi-end Data Acquisition system show that
model with EQRF behave better than without EQRF. This modified
masonry model with new material combined with new bands is used
to improve the behavior of masonry building.
Abstract: This paper focuses on the Mega-Sub Controlled
Structure Systems (MSCSS) performances and characteristics
regarding the new control principle contained in MSCSS subjected to
strong earthquake excitations. The adopted control scheme consists of
modulated sub-structures where the control action is achieved by
viscous dampers and sub-structure own configuration. The
elastic-plastic time history analysis under severe earthquake excitation
is analyzed base on the Finite Element Analysis Method (FEAM), and
some comparison results are also given in this paper. The result shows
that the MSCSS systems can remarkably reduce vibrations effects
more than the mega-sub structure (MSS). The study illustrates that the
improved MSCSS presents good seismic resistance ability even at 1.2g
and can absorb seismic energy in the structure, thus imply that
structural members cross section can be reduce and achieve to good
economic characteristics. Furthermore, the elasto-plastic analysis
demonstrates that the MSCSS is accurate enough regarding
international building evaluation and design codes. This paper also
shows that the elasto-plastic dynamic analysis method is a reasonable
and reliable analysis method for structures subjected to strong
earthquake excitations and that the computed results are more precise.
Abstract: The seismic rehabilitation designs of two reinforced
concrete school buildings, representative of a wide stock of similar
edifices designed under earlier editions of the Italian Technical
Standards, are presented in this paper. The mutual retrofit solution
elaborated for the two buildings consists in the incorporation of a
dissipative bracing system including pressurized fluid viscous springdampers
as passive protective devices. The mechanical parameters,
layouts and locations selected for the constituting elements of the
system; the architectural renovation projects developed to properly
incorporate the structural interventions and improve the appearance
of the buildings; highlights of the installation works already
completed in one of the two structures; and a synthesis of the
performance assessment analyses carried out in original and
rehabilitated conditions, are illustrated. The results of the analyses
show a remarkable enhancement of the seismic response capacities of
both structures. This allows reaching the high performance objectives
postulated in the retrofit designs with much lower costs and
architectural intrusion as compared to traditional rehabilitation
interventions designed for the same objectives.