Abstract: The present work involves measurements to examine
the effects of initial conditions on aerodynamic and acoustic
characteristics of a Jet at M=0.8 by changing the orientation of sharp
edged orifice plate. A thick plate with chamfered orifice presented divergent and convergent openings when it was flipped over. The centerline velocity was found to decay more rapidly for divergent
orifice and that was consistent with the enhanced mass entrainment
suggesting quicker spread of the jet compared with that from the convergent orifice. The mixing layer region elucidated this effect of
initial conditions at an early stage – the growth was found to be comparatively more pronounced for the divergent orifice resulting in
reduced potential core size. The acoustic measurements, carried out in the near field noise region outside the jet within potential core
length, showed the jet from the divergent orifice to be less noisy. The frequency spectra of the noise signal exhibited that in the initial
region of comparatively thin mixing layer for the convergent orifice,
the peak registered a higher SPL and a higher frequency as well. The noise spectra and the mixing layer development suggested a direct correlation between the coherent structures developing in the initial
region of the jet and the noise captured in the surrounding near field.
Abstract: The sensitivity of orifice plate metering to disturbed
flow (either asymmetric or swirling) is a subject of great concern to
flow meter users and manufacturers. The distortions caused by pipe
fittings and pipe installations upstream of the orifice plate are major
sources of this type of non-standard flows. These distortions can alter
the accuracy of metering to an unacceptable degree. In this work, a
multi-scale object known as metal foam has been used to generate a
predetermined turbulent flow upstream of the orifice plate. The
experimental results showed that the combination of an orifice plate
and metal foam flow conditioner is broadly insensitive to upstream
disturbances. This metal foam demonstrated a good performance in
terms of removing swirl and producing a repeatable flow profile
within a short distance downstream of the device. The results of using
a combination of a metal foam flow conditioner and orifice plate for
non-standard flow conditions including swirling flow and asymmetric
flow show this package can preserve the accuracy of metering up to
the level required in the standards.
Abstract: The present paper represents a methodology for
investigating flow characteristics near orifice plate by using a
commercial computational fluid dynamics code. The flow
characteristics near orifice plate which is located in the auxiliary
feedwater system were modeled via three different levels of grid and
four different types of Reynolds Averaged Navier-Stokes (RANS)
equations with proper near-wall treatment. The results from CFD code
were compared with experimental data in terms of differential pressure
through the orifice plate. In this preliminary study, the Realizable k-ε
and the Reynolds stress models with enhanced wall treatment were
suitable to analyze flow characteristics near orifice plate, and the
results had a good agreement with experimental data.