Abstract: The paper presents an approach to improve the reliability and reduce line losses of practical distribution system applying network reconfiguration. The change of the topology redirects the power flow within the distribution network to obtain better performance of the system. Practical distribution network (Pyigyitagon Industrial Zone (I)) is used as the case study network. The detailed calculations of the reliability indices are done by using analytical method and power flow calculation is performed by Newton-Rephason solver. The comparison of various network reconfiguration techniques are described with respect to power loss and reliability index levels. Finally, the optimal reconfigured network is selected among difference cases based on the two factors: the most reliable network and the least loss minimization.
Abstract: Renewable energy sources and distributed power generation units already have an important role in electrical power generation. A mixture of different technologies penetrating the electrical grid, adds complexity in the management of distribution networks. High penetration of distributed power generation units creates node over-voltages, huge power losses, unreliable power management, reverse power flow and congestion. This paper presents an optimization algorithm capable of reducing congestion and power losses, both described as a function of weighted sum. Two factors that describe congestion are being proposed. An upgraded selective particle swarm optimization algorithm (SPSO) is used as a solution tool focusing on the technique of network reconfiguration. The upgraded SPSO algorithm is achieved with the addition of a heuristic algorithm specializing in reduction of power losses, with several scenarios being tested. Results show significant improvement in minimization of losses and congestion while achieving very small calculation times.
Abstract: Generally, distributed generation units refer to small-scale electric power generators that produce electricity at a site close to the customer or an electric distribution system (in parallel mode). From the customers’ point of view, a potentially lower cost, higher service reliability, high power quality, increased energy efficiency, and energy independence can be the key points of a proper DG unit. Moreover, the use of renewable types of distributed generations such as wind, photovoltaic, geothermal or hydroelectric power can also provide significant environmental benefits. Therefore, it is of crucial importance to study their impacts on the distribution networks. A marked increase in Distributed Generation (DG), associated with medium voltage distribution networks, may be expected. Nowadays, distribution networks are planned for unidirectional power flows that are peculiar to passive systems, and voltage control is carried out exclusively by varying the tap position of the HV/MV transformer. This paper will compare different DG control methods and possible network reconfiguration aimed at assessing their effect on voltage profiles.
Abstract: Recently, distributed generation technologies have received much attention for the potential energy savings and reliability assurances that might be achieved as a result of their widespread adoption. The distribution feeder reconfiguration (DFR) is one of the most important control schemes in the distribution networks, which can be affected by DGs. This paper presents a new approach to DFR at the distribution networks considering wind turbines. The main objective of the DFR is to minimize the deviation of the bus voltage. Since the DFR is a nonlinear optimization problem, we apply the Adaptive Modified Firefly Optimization (AMFO) approach to solve it. As a result of the conflicting behavior of the single- objective function, a fuzzy based clustering technique is employed to reach the set of optimal solutions called Pareto solutions. The approach is tested on the IEEE 32-bus standard test system.
Abstract: Power distribution systems typically have tie and sectionalizing switches whose states determine the topological configuration of the network. The aim of network reconfiguration of the distribution network is to minimize the losses for a load arrangement at a particular time. Thus the objective function is to minimize the losses of the network by satisfying the distribution network constraints. The various constraints are radiality, voltage limits and the power balance condition. In this paper the status of the switches is obtained by using Artificial Bee Colony (ABC) algorithm. ABC is based on a particular intelligent behavior of honeybee swarms. ABC is developed based on inspecting the behaviors of real bees to find nectar and sharing the information of food sources to the bees in the hive. The proposed methodology has three stages. In stage one ABC is used to find the tie switches, in stage two the identified tie switches are checked for radiality constraint and if the radilaity constraint is satisfied then the procedure is proceeded to stage three otherwise the process is repeated. In stage three load flow analysis is performed. The process is repeated till the losses are minimized. The ABC is implemented to find the power flow path and the Forward Sweeper algorithm is used to calculate the power flow parameters. The proposed methodology is applied for a 33–bus single feeder distribution network using MATLAB.
Abstract: In today scenario, to meet enhanced demand imposed
by domestic, commercial and industrial consumers, various
operational & control activities of Radial Distribution Network
(RDN) requires a focused attention. Irrespective of sub-domains
research aspects of RDN like network reconfiguration, reactive
power compensation and economic load scheduling etc, network
performance parameters are usually estimated by an iterative process
and is commonly known as load (power) flow algorithm. In this
paper, a simple mechanism is presented to implement the load flow
analysis (LFA) algorithm. The reported algorithm utilizes graph
theory principles and is tested on a 69- bus RDN.
Abstract: Network reconfiguration is an operation to modify the
network topology. The implementation of network reconfiguration
has many advantages such as loss minimization, increasing system
security and others. In this paper, two topics about the network
reconfiguration in distribution system are briefly described. The first
topic summarizes its impacts while the second explains some
heuristic optimization techniques for solving the network
reconfiguration problem.
Abstract: This paper presents an efficient algorithm for
optimization of radial distribution systems by a network
reconfiguration to balance feeder loads and eliminate overload
conditions. The system load-balancing index is used to determine the
loading conditions of the system and maximum system loading
capacity. The index value has to be minimum in the optimal network
reconfiguration of load balancing. A method based on Tabu search
algorithm, The Tabu search algorithm is employed to search for the
optimal network reconfiguration. The basic idea behind the search is
a move from a current solution to its neighborhood by effectively
utilizing a memory to provide an efficient search for optimality. It
presents low computational effort and is able to find good quality
configurations. Simulation results for a radial 69-bus system with
distributed generations and capacitors placement. The study results
show that the optimal on/off patterns of the switches can be identified
to give the best network reconfiguration involving balancing of
feeder loads while respecting all the constraints.
Abstract: This paper presents a novel approach for optimal
reconfiguration of radial distribution systems. Optimal
reconfiguration involves the selection of the best set of branches to
be opened, one each from each loop, such that the resulting radial
distribution system gets the desired performance. In this paper an
algorithm is proposed based on simple heuristic rules and identified
an effective switch status configuration of distribution system for the
minimum loss reduction. This proposed algorithm consists of two
parts; one is to determine the best switching combinations in all loops
with minimum computational effort and the other is simple optimum
power loss calculation of the best switching combination found in
part one by load flows. To demonstrate the validity of the proposed
algorithm, computer simulations are carried out on 33-bus system.
The results show that the performance of the proposed method is
better than that of the other methods.
Abstract: Individually Network reconfiguration or Capacitor control
perform well in minimizing power loss and improving voltage
profile of the distribution system. But for heavy reactive power loads
network reconfiguration and for heavy active power loads capacitor
placement can not effectively reduce power loss and enhance
voltage profiles in the system. In this paper, an hybrid approach
that combine network reconfiguration and capacitor placement using
Harmony Search Algorithm (HSA) is proposed to minimize power
loss reduction and improve voltage profile. The proposed approach
is tested on standard IEEE 33 and 16 bus systems. Computational
results show that the proposed hybrid approach can minimize losses
more efficiently than Network reconfiguration or Capacitor control.
The results of proposed method are also compared with results
obtained by Simulated Annealing (SA). The proposed method has
outperformed in terms of the quality of solution compared to SA.
Abstract: Power loss reduction is one of the main targets in power industry and so in this paper, the problem of finding the optimal configuration of a radial distribution system for loss reduction is considered. Optimal reconfiguration involves the selection of the best set of branches to be opened ,one each from each loop, for reducing resistive line losses , and reliving overloads on feeders by shifting the load to adjacent feeders. However ,since there are many candidate switching combinations in the system ,the feeder reconfiguration is a complicated problem. In this paper a new approach is proposed based on a simple optimum loss calculation by determining optimal trees of the given network. From graph theory a distribution network can be represented with a graph that consists a set of nodes and branches. In fact this problem can be viewed as a problem of determining an optimal tree of the graph which simultaneously ensure radial structure of each candidate topology .In this method the refined genetic algorithm is also set up and some improvements of algorithm are made on chromosome coding. In this paper an implementation of the algorithm presented by [7] is applied by modifying in load flow program and a comparison of this method with the proposed method is employed. In [7] an algorithm is proposed that the choice of the switches to be opened is based on simple heuristic rules. This algorithm reduce the number of load flow runs and also reduce the switching combinations to a fewer number and gives the optimum solution. To demonstrate the validity of these methods computer simulations with PSAT and MATLAB programs are carried out on 33-bus test system. The results show that the performance of the proposed method is better than [7] method and also other methods.
Abstract: Network reconfiguration in distribution system is realized by changing the status of sectionalizing switches to reduce the power loss in the system. This paper presents a new method which applies an artificial bee colony algorithm (ABC) for determining the sectionalizing switch to be operated in order to solve the distribution system loss minimization problem. The ABC algorithm is a new population based metaheuristic approach inspired by intelligent foraging behavior of honeybee swarm. The advantage of ABC algorithm is that it does not require external parameters such as cross over rate and mutation rate as in case of genetic algorithm and differential evolution and it is hard to determine these parameters in prior. The other advantage is that the global search ability in the algorithm is implemented by introducing neighborhood source production mechanism which is a similar to mutation process. To demonstrate the validity of the proposed algorithm, computer simulations are carried out on 14, 33, and 119-bus systems and compared with different approaches available in the literature. The proposed method has outperformed the other methods in terms of the quality of solution and computational efficiency.