Abstract: We present a dextran modified silicon microring
resonator sensor for high density antibody immobilization. An array
of sensors consisting of three sensor rings and a reference ring was
fabricated and its surface sensitivity and the limit of detection were
obtained using polyelectrolyte multilayers. The mass sensitivity and
the limit of detection of the fabricated sensor ring are 0.35 nm/ng
mm-2 and 42.8 pg/mm2 in air, respectively. Dextran modified sensor
surface was successfully prepared by covalent grafting of oxidized
dextran on 3-aminopropyltriethoxysilane (APTES) modified silicon
sensor surface. The antibody immobilization on hydrogel dextran
matrix improves 40% compared to traditional antibody
immobilization method via APTES and glutaraldehyde linkage.
Abstract: We propose an all optical flip-flop circuit composedof two Silicon-on-insulator microring resonators coupled to straightwaveguides by exploiting the optical bistability behavior due to thenonlinear Kerr effect. We used the transfer matrix analysis toinvestigate continuous wave propagation through microrings, as wellwe considered the nonlinear switching characteristics of an opticaldevice using a double-coupler silicon ring resonator in presence ofthe Kerr nonlinearity, thus obtaining the bistability behavior of theoutput port, the drop port and also inside the silicon microringresonator. It is shown that the bistability behavior depends on thecontrol of the input wavelength.KeywordsAll optical flip-flops, Kerr effect, microringresonator, optical bistability.