Abstract: Linear actuators are deployed in a wide range of applications. This paper presents the modeling and system identification of a variable excited linear direct drive (LDD). The LDD is designed based on linear hybrid stepper technology exhibiting the characteristic tooth structure of mover and stator. A three-phase topology provides the thrust force caused by alternating strengthening and weakening of the flux of the legs. To achieve best possible synchronous operation, the phases are commutated sinusoidal. Despite the fact that these LDDs provide high dynamics and drive forces, noise emission limits their operation in calm workspaces. To overcome this drawback an additional excitation of the magnetic circuit is introduced to LDD using additional enabling coils instead of permanent magnets. The new degree of freedom can be used to reduce force variations and related noise by varying the excitation flux that is usually generated by permanent magnets. Hence, an identified simulation model is necessary to analyze the effects of this modification. Especially the force variations must be modeled well in order to reduce them sufficiently. The model can be divided into three parts: the current dynamics, the mechanics and the force functions. These subsystems are described with differential equations or nonlinear analytic functions, respectively. Ordinary nonlinear differential equations are derived and transformed into state space representation. Experiments have been carried out on a test rig to identify the system parameters of the complete model. Static and dynamic simulation based optimizations are utilized for identification. The results are verified in time and frequency domain. Finally, the identified model provides a basis for later design of control strategies to reduce existing force variations.
Abstract: Robotic surgery is used to enhance minimally invasive
surgical procedure. It provides greater degree of freedom for surgical
tools but lacks of haptic feedback system to provide sense of touch to
the surgeon. Surgical robots work on master-slave operation, where
user is a master and robotic arms are the slaves. Current, surgical
robots provide precise control of the surgical tools, but heavily rely
on visual feedback, which sometimes cause damage to the inner
organs. The goal of this research was to design and develop a realtime
Simulink based robotic system to study force feedback
mechanism during instrument-object interaction. Setup includes three
VelmexXSlide assembly (XYZ Stage) for three dimensional
movement, an end effector assembly for forceps, electronic circuit for
four strain gages, two Novint Falcon 3D gaming controllers,
microcontroller board with linear actuators, MATLAB and Simulink
toolboxes. Strain gages were calibrated using Imada Digital Force
Gauge device and tested with a hard-core wire to measure
instrument-object interaction in the range of 0-35N. Designed
Simulink model successfully acquires 3D coordinates from two
Novint Falcon controllers and transfer coordinates to the XYZ stage
and forceps. Simulink model also reads strain gages signal through
10-bit analog to digital converter resolution of a microcontroller
assembly in real time, converts voltage into force and feedback the
output signals to the Novint Falcon controller for force feedback
mechanism. Experimental setup allows user to change forward
kinematics algorithms to achieve the best-desired movement of the
XYZ stage and forceps. This project combines haptic technology
with surgical robot to provide sense of touch to the user controlling
forceps through machine-computer interface.
Abstract: The Ambidextrous Robot Hand is a robotic device with the purpose to mimic either the gestures of a right or a left hand. The symmetrical behavior of its fingers allows them to bend in one way or another keeping a compliant and anthropomorphic shape. However, in addition to gestures they can reproduce on both sides, an asymmetrical mechanical design with a three tendons routing has been engineered to reduce the number of actuators. As a consequence, control algorithms must be adapted to drive efficiently the ambidextrous fingers from one position to another and to include grasping features. These movements are controlled by pneumatic muscles, which are nonlinear actuators. As their elasticity constantly varies when they are under actuation, the length of pneumatic muscles and the force they provide may differ for a same value of pressurized air. The control algorithms introduced in this paper take both the fingers asymmetrical design and the pneumatic muscles nonlinearity into account to permit an accurate control of the Ambidextrous Robot Hand. The finger motion is achieved by combining a classic PID controller with a phase plane switching control that turns the gain constants into dynamic values. The grasping ability is made possible because of a sliding mode control that makes the fingers adapt to the shape of an object before strengthening their positions.
Abstract: Comparison of two approaches for the simulation of
the dynamic behaviour of a permanent magnet linear actuator is
presented. These are full coupled model, where the electromagnetic
field, electric circuit and mechanical motion problems are solved
simultaneously, and decoupled model, where first a set of static
magnetic filed analysis is carried out and then the electric circuit and
mechanical motion equations are solved employing bi-cubic spline
approximations of the field analysis results. The results show that the
proposed decoupled model is of satisfactory accuracy and gives more
flexibility when the actuator response is required to be estimated for
different external conditions, e.g. external circuit parameters or
mechanical loads.