Abstract: The performance of box-type solar cookers has been
reported by several researchers but little attention was paid to the
effect of the type of insulation material on the energy and exergy
efficiency of these cookers. This research aimed at evaluating the
energy and exergy efficiencies of the box-type cookers containing
different insulation materials. Energy and exergy efficiencies of five
box-type solar cookers insulated with maize cob, air (control), maize
husk, coconut coir and polyurethane foam respectively were obtained
over a period of three years. The cookers were evaluated using water
heating test procedures in determining the energy and exergy
analysis. The results were subjected to statistical analysis using
ANOVA. The result shows that the average energy input for the five
solar cookers were: 245.5, 252.2, 248.7, 241.5 and 245.5J
respectively while their respective average energy losses were: 201.2,
212.7, 208.4, 189.1 and 199.8J. The average exergy input for five
cookers were: 228.2, 234.4, 231.1, 224.4 and 228.2J respectively
while their respective average exergy losses were: 223.4, 230.6,
226.9, 218.9 and 223.0J. The energy and exergy efficiency was
highest in the cooker with coconut coir (37.35 and 3.90%
respectively) in the first year but was lowest for air (11 and 1.07%
respectively) in the third year. Statistical analysis showed significant
difference between the energy and exergy efficiencies over the years.
These results reiterate the importance of a good insulating material
for a box-type solar cooker.
Abstract: The concern with sustainability brought the need for optimization of the buildings to reduce consumption of natural resources. Almost 1/3 of energy demanded by Brazilian housings is used to provide thermal solutions. AEC sector may contribute applying bioclimatic strategies on building design. The aim of this research is to investigate the viability of applying some alternative solutions in residential buildings. The research was developed with computational simulation on single family social housing, examining envelope type, absorptance, and insolation. The analysis of the thermal performance applied both Brazilian standard NBR 15575 and degree-hour method, in the scenery of Porto Alegre, a southern Brazilian city. We used BIM modeling through Revit/Autodesk and used Energy Plus to thermal simulation. The payback of the investment was calculated comparing energy savings and building costs, in a period of 50 years. The results shown that with the increment of envelope’s insulation there is thermal comfort improvement and energy economy, with a pay-back period of 24 to 36 years, in some cases.