Abstract: The current statuses of lifetime test of LaB6 hollow
cathode at the Lanzhou Institute of Physics (LIP), China, was
described. 5A LaB6 hollow cathode was design for LIPS-200 40mN
Xenon ion thruster, and it could be used for LHT-100 80 mN Hall
thruster, too. Life test of the discharge and neutralizer modes of LHC-5
hollow cathode were stared in October 2011, and cumulative operation
time reached 17,300 and 16,100 hours in April 2015, respectively. The
life of cathode was designed more than 11,000 hours. Parameters of
discharge and key structure dimensions were monitored in different
stage of life test indicated that cathodes were health enough. The test
will continue until the cathode cannot work or operation parameter is
not in normally. The result of the endurance test of cathode
demonstrated that the LaB6 hollow cathode is satisfied for the required
of thruster in life and performance.