Abstract: In order to compare the performance of the carbon dioxide and HFC-125 heat pumps for medium-and high-temperature heating, both heat pump cycles were optimized using a simulation method. To fairly compare the performance of the cycles by using different working fluids, each cycle was optimized from the viewpoint of heating COP by two design parameters. The first is the gas cooler exit temperature and the other is the ratio of the overall heat conductance of the gas cooler to the combined overall heat conductance of the gas cooler and the evaporator. The inlet and outlet temperatures of secondary fluid of the gas cooler were fixed at 40/90°C and 40/150°C.The results shows that the HFC-125 heat pump has 6% higher heating COP than carbon dioxide heat pump when the heat sink exit temperature is fixed at 90ºC, while the latter outperforms the former when the heat sink exit temperature is fixed at 150ºC under the simulation conditions considered in the present study.
Abstract: The compression-absorption heat pump (C-A HP), one
of the promising heat recovery equipments that make process hot
water using low temperature heat of wastewater, was evaluated by
computer simulation. A simulation program was developed based on
the continuity and the first and second laws of thermodynamics. Both
the absorber and desorber were modeled using UA-LMTD method. In
order to prevent an unfeasible temperature profile and to reduce
calculation errors from the curved temperature profile of a mixture,
heat loads were divided into lots of segments. A single-stage
compressor was considered. A compressor cooling load was also
taken into account. An isentropic efficiency was computed from the
map data. Simulation conditions were given based on the system
consisting of ordinarily designed components. The simulation results
show that most of the total entropy generation occurs during the
compression and cooling process, thus suggesting the possibility that
system performance can be enhanced if a rectifier is introduced.
Abstract: The performances of a thermoacoustic travelling-wave
refrigerator are presented. Developed in the frame of the European
project called THATEA, it is designed for providing 600 W at a
temperature of 233 K with an efficiency of 40 % relative to the
Carnot efficiency. This paper presents the device and the results of
the first measurements. For a cooling power of 210 W, a coefficient
of performance relative to Carnot of 30 % is achieved when the
refrigerator is coupled with an existing standing-wave engine.
Abstract: The peel of dragon fruit is a byproduct left over after consuming. Normally, the use of plants as antioxidant source must be dried before further process. Therefore, the aim of this study is interesting to dry the peel by heat pump dryer (45 ºC) and fluidized bed dryer (110 º C) compared with the sun drying method. The sample with initial moisture content of about 85-91% wet basis was dried down to about 10% wet basis where it took 620 and 25 min for heat pump dryer and fluidized bed dryer, respectively. However, the sun drying took about 900 min to dry the peel. After that, sample was evaluated antioxidant activity, -carotene and betalains contents. The results found that the antioxidant activity and betalains contents of dried peel obtained from heat pump and fluidized bed dryings were significantly higher than that sun drying (p 0.05). Moreover, the drying by heat pump provided the highest -carotene content.
Abstract: Accurate and comprehensive thermodynamic properties of pure and mixture of refrigerants are in demand by both producers and users of these materials. Information about thermodynamic properties is important initially to qualify potential candidates for working fluids in refrigeration machinery. From practical point of view, Refrigerants and refrigerant mixtures are widely used as working fluids in many industrial applications, such as refrigerators, heat pumps, and power plants The present work is devoted to evaluating seven cubic equations of state (EOS) in predicting gas and liquid phase volumetric properties of nine ozone-safe refrigerants both in super and sub-critical regions. The evaluations, in sub-critical region, show that TWU and PR EOS are capable of predicting PVT properties of refrigerants R32 within 2%, R22, R134a, R152a and R143a within 1% and R123, R124, R125, TWU and PR EOS's, from literature data are 0.5% for R22, R32, R152a, R143a, and R125, 1% for R123, R134a, and R141b, and 2% for R124. Moreover, SRK EOS predicts PVT properties of R22, R125, and R123 to within aforementioned errors. The remaining EOS's predicts volumetric properties of this class of fluids with higher errors than those above mentioned which are at most 8%.In general, the results are in favor of the preference of TWU and PR EOS over other remaining EOS's in predicting densities of all mentioned refrigerants in both super and sub critical regions. Typically, this refrigerant is known to offer advantages such as ozone depleting potential equal to zero, Global warming potential equal to 140, and no toxic.
Abstract: In the present study, a steady-state simulation model
has been developed to evaluate the system performance of a
transcritical carbon dioxide heat pump system for simultaneous water
cooling and heating. Both the evaporator (including both two-phase
and superheated zone) and gas cooler models consider the highly
variable heat transfer characteristics of CO2 and pressure drop. The
numerical simulation model of transcritical CO2 heat pump has been
validated by test data obtained from experiments on the heat pump
prototype. Comparison between the test results and the model
prediction for system COP variation with compressor discharge
pressure shows a modest agreement with a maximum deviation of
15% and the trends are fairly similar. Comparison for other operating
parameters also shows fairly similar deviation between the test
results and the model prediction. Finally, the simulation results are
presented to study the effects of operating parameters such as,
temperature of heat exchanger fluid at the inlet, discharge pressure,
compressor speed on system performance of CO2 heat pump, suitable
in a dairy plant where simultaneous cooling at 4oC and heating at
73oC are required. Results show that good heat transfer properties of
CO2 for both two-phase and supercritical region and efficient
compression process contribute a lot for high system COPs.
Abstract: This research evaluated and compared the thermodynamic performance of heat pump systems which can be run under two different modes as air to air and air to water by using only one compressor. To achieve this comparison an experimental performance study was made on a traditional vapor compressed heat pump system that can be run air to air mode and air to water mode by help of a valve. The experiments made under different thermal conditions. Thermodynamic performance of the systems are presented and compared with each other for different working conditions.
Abstract: The paper presents the results of the European EIE
project “Realising the potential for small scale renewable energy
sources in the home – Kyotointhehome". The project's global aim is
to inform and educate teachers, students and their families so that
they can realise the need and can assess the potential for energy
efficiency (EE) measures and renewable energy sources (RES) in
their homes. The project resources were translated and trialled by 16
partners in 10 European countries.
A web-based methodology which will enable families to assess
how RES can be incorporated into energy efficient homes was
accomplished. The web application “KYOTOINHOME" will help
the citizens to identify what they can do to help their community
meet the Kyoto target for greenhouse gas reductions and prevent
global warming. This application provides useful information on how
the citizens can use renewable energy sources in their home to
provide space heating and cooling, hot water and electricity. A
methodology for assessing heat loss in a dwelling and application of
heat pump system was elaborated and will be implemented this year.
For schools, we developed a set of practical activities concerned with
preventing climate change through using renewable energy sources.
Complementary resources will also developed in the Romanian
research project “Romania Contribution to the European Targets
Regarding the Development of Renewable Energy Sources" -
PROMES.
Abstract: Vapour recompression system has been used to
enhance reduction in energy consumption and improvement in
energy effectiveness of distillation columns. However, the effects of
certain parameters have not been taken into consideration. One of
such parameters is the column heat loss which has either been
assumed to be a certain percent of reboiler heat transfer or negligible.
The purpose of this study was to evaluate the heat loss from an
ethanol-water vapour recompression distillation column with
pressure increase across the compressor (VRCAS) and compare the
results obtained and its effect on some parameters in similar system
(VRCCS) where the column heat loss has been assumed or neglected.
Results show that the heat loss evaluated was higher when compared
with that obtained for the column VRCCS. The results also showed
that increase in heat loss could have significant effect on the total
energy consumption, reboiler heat transfer, the number of trays and
energy effectiveness of the column.