A Study on Cement-Based Composite Containing Polypropylene Fibers and Finely Ground Glass Exposed to Elevated Temperatures

High strength concrete has been used in situations where it may be exposed to elevated temperatures. Numerous authors have shown the significant contribution of polypropylene fiber to the spalling resistance of high strength concrete. When cement-based composite that reinforced by polypropylene fibers heated up to 170 °C, polypropylene fibers readily melt and volatilize, creating additional porosity and small channels in to the matrix that cause the poor structure and low strength. This investigation develops on the mechanical properties of mortar incorporating polypropylene fibers exposed to high temperature. Also effects of different pozzolans on strength behaviour of samples at elevated temperature have been studied. To reach this purpose, the specimens were produced by partial replacement of cement with finely ground glass, silica fume and rice husk ash as high reactive pozzolans. The amount of this replacement was 10% by weight of cement to find the effects of pozzolans as a partial replacement of cement on the mechanical properties of mortars. In this way, lots of mixtures with 0%, 0.5%, 1% and 1.5% of polypropylene fibers were cast and tested for compressive and flexural strength, accordance to ASTM standard. After that specimens being heated to temperatures of 300, 600 °C, respectively, the mechanical properties of heated samples were tested. Mechanical tests showed significant reduction in compressive strength which could be due to polypropylene fiber melting. Also pozzolans improve the mechanical properties of sampels.

Anticoagulatory Role of an Ergot Mesylate: Hydergine

Thrombosis can be life threatening, necessitating therefore its instant treatment. Hydergine, a nootropic agent is used as a cognition enhancer in stroke patients but relatively little is known about its anti-thrombolytic effect. To investigate this aspect, in vivo and ex vivo experiments were designed and conducted. Three groups of rats were injected 1.5mg, 3.0mg and 4.5mg hydergine intraperitonealy with and without prior exposure to fresh plasma. Positive and negative controls were run in parallel. Animals were sacrificed after 1.5hrs and BT, CT, PT, INR, APTT, plasma calcium levels were estimated. For ex vivo analyses, each 1ml blood aspirated was exposed to 0.1mg, 0.2mg, 0.3mg dose of hydergine with parallel controls. Parameters analyzed were as above. Statistical analysis was through one-way ANOVA. Dunken-s and Tukey-s tests provided intra-group variance. BT, CT, PT, INR and APTT increased while calcium levels dropped significantly (P

Biaxial Testing of Fabrics - A Comparison of Various Testing Methodologies

In textile industry, besides the conventional textile products, technical textile goods, that have been brought external functional properties into, are being developed for technical textile industry. Especially these products produced with weaving technology are widely preferred in areas such as sports, geology, medical, automotive, construction and marine sectors. These textile products are exposed to various stresses and large deformations under typical conditions of use. At this point, sufficient and reliable data could not be obtained with uniaxial tensile tests for determination of the mechanical properties of such products due to mainly biaxial stress state. Therefore, the most preferred method is a biaxial tensile test method and analysis. These tests and analysis is applied to fabrics with different functional features in order to establish the textile material with several characteristics and mechanical properties of the product. Planar biaxial tensile test, cylindrical inflation and bulge tests are generally required to apply for textile products that are used in automotive, sailing and sports areas and construction industry to minimize accidents as long as their service life. Airbags, seat belts and car tires in the automotive sector are also subject to the same biaxial stress states, and can be characterized by same types of experiments. In this study, in accordance with the research literature related to the various biaxial test methods are compared. Results with discussions are elaborated mainly focusing on the design of a biaxial test apparatus to obtain applicable experimental data for developing a finite element model. Sample experimental results on a prototype system are expressed.

Aggressive Interactions in Hospital Emergency Units

International literature emphasizes on the concern regarding the phenomenon of aggression in hospital. This paper focuses on the reality of aggressive interactions reigning within an emergency triage involving three chaps of protagonists: the professionals, the patients and their carers. The data collection was made from a grid of observation, in which the various variables exposed in the literature were integrated. They observations took place around the clock, for three weeks, at the rate of one week a month. In this research 331 aggressive interactions have been listed and analyzed by means of the software SPSS. This research is one of the very few continuous observation surveys in the literature. It shows the various human factors at play in the emergence of aggressive interaction. The data may be used both for taking steps in primary prevention, thanks to the analysis of interaction modes, and in secondary prevention by integrating the useful results in situational prevention.

Heat and Mass Transfer in a Solar Dryer with Biomass Backup Burner

Majority of pepper farmers in Malaysia are using the open-sun method for drying the pepper berries. This method is time consuming and exposed the berries to rain and contamination. A maintenance-friendly and properly enclosed dryer is therefore desired. A dryer design with a solar collector and a chimney was studied and adapted to suit the needs of small-scale pepper farmers in Malaysia. The dryer will provide an environment with an optimum operating temperature meant for drying pepper berries. The dryer model was evaluated by using commercially available computational fluid dynamic (CFD) software in order to understand the heat and mass transfer inside the dryer. Natural convection was the only mode of heat transportation considered in this study as in accordance to the idea of having a simple and maintenance-friendly design. To accommodate the effect of low buoyancy found in natural convection driers, a biomass burner was integrated into the solar dryer design.

A New Self-Adaptive EP Approach for ANN Weights Training

Evolutionary Programming (EP) represents a methodology of Evolutionary Algorithms (EA) in which mutation is considered as a main reproduction operator. This paper presents a novel EP approach for Artificial Neural Networks (ANN) learning. The proposed strategy consists of two components: the self-adaptive, which contains phenotype information and the dynamic, which is described by genotype. Self-adaptation is achieved by the addition of a value, called the network weight, which depends on a total number of hidden layers and an average number of neurons in hidden layers. The dynamic component changes its value depending on the fitness of a chromosome, exposed to mutation. Thus, the mutation step size is controlled by two components, encapsulated in the algorithm, which adjust it according to the characteristics of a predefined ANN architecture and the fitness of a particular chromosome. The comparative analysis of the proposed approach and the classical EP (Gaussian mutation) showed, that that the significant acceleration of the evolution process is achieved by using both phenotype and genotype information in the mutation strategy.

Dynamical Network Transmission of H1N1 Virus at the Local Level Transmission Model

A new strain of Type A influenza virus can cause the transmission of H1N1 virus. This virus can spread between the people by coughing and sneezing. Because the people are always movement, so this virus can be easily spread. In this study, we construct the dynamical network model of H1N1 virus by separating the human into five groups; susceptible, exposed, infectious, quarantine and recovered groups. The movement of people between houses (local level) is considered. The behaviors of solutions to our dynamical model are shown for the different parameters.

Detection of Airborne Bacteria and Mildew in the Shanghai Metro System

This study aimed to detect and to identify the main strains of airborne microorganisms present in the Shanghai Metro system. Samples were collected using agar plates exposed to the air and microorganisms were identified using catalase, plasma coagulase and hymolytic analysis. The results show that the concentration of mildew present within a newly opened metro line was significantly higher than for other lines. Differences among underground and elevated stations can be attributed to differences in passenger flow and the environment surrounding the stations. Additionally, the investigation indicated that bacteria reached maximum levels at different times on weekdays and weekends. The bacteria in the Metro stations were identified as primarily Gram positive, consisting mainly of coagulase-negative staphylococcus strains (CNS).

Chemical Destabilization on Water in Crude Oil Emulsions

Experimental data are presented to show the influence of different types of chemical demulsifier on the stability and demulsification of emulsions. Three groups of demulsifier with different functional groups were used in this work namely amines, alcohol and polyhydric alcohol. The results obtained in this study have exposed the capability of chemical breaking agents in destabilization of water in crude oil emulsions. From the present study, found that molecular weight of the demulsifier were influent the capability of the emulsion to separate.