Abstract: The purpose of this article is to optimize the Equivalent Electric Circuit Model (EECM) of different orders to obtain greater precision in the modeling of Li-ion battery packs. Optimization includes considering circuits based on 1RC, 2RC and 3RC networks, with a dependent voltage source and a series resistor. The parameters are obtained experimentally using tests in the time domain and in the frequency domain. Due to the high non-linearity of the behavior of the battery pack, Genetic Algorithm (GA) was used to solve and optimize the parameters of each EECM considered (1RC, 2RC and 3RC). The objective of the estimation is to minimize the mean square error between the measured impedance in the real battery pack and those generated by the simulation of different proposed circuit models. The results have been verified by comparing the Nyquist graphs of the estimation of the complex impedance of the pack. As a result of the optimization, the 2RC and 3RC circuit alternatives are considered as viable to represent the battery behavior. These battery pack models are experimentally validated using a hardware-in-the-loop (HIL) simulation platform that reproduces the well-known New York City cycle (NYCC) and Federal Test Procedure (FTP) driving cycles for electric vehicles. The results show that using GA optimization allows obtaining EECs with 2RC or 3RC networks, with high precision to represent the dynamic behavior of a battery pack in vehicular applications.
Abstract: Cole-Cole parameters of 40 post-menopausal women
are compared with their DEXA bone mineral density measurements.
Impedance characteristics of four extremities are compared; left and
right extremities are statistically same, but lower extremities are
statistically different than upper ones due to their different fat
content. The correlation of Cole-Cole impedance parameters to bone
mineral density (BMD) is observed to be higher for dominant arm.
With the post-menopausal population, ANOVA tests of the dominant
arm characteristic frequency, as a predictor for DEXA classified
osteopenic and osteoporic population around lumbar spine, is
statistically very significant. When used for total lumbar spine
osteoporosis diagnosis, the area under the Receiver Operating Curve
of the characteristic frequency is 0.830, suggesting that the Cole-Cole
plot characteristic frequency could be a useful diagnostic parameter
when integrated into standard screening methods for osteoporosis.
Moreover, the characteristic frequency can be directly measured by
monitoring frequency driven angular behavior of the dominant arm
without performing any complex calculation.
Abstract: The coaxial transformer-coupled push-pull circuitry
has been used widely in HF and VHF amplifiers for many decades
without significant changes in the topology of the transformers. Basic
changes over the years concerned the construction and turns ratio of
the transformers as has been imposed upon the newer technologies
active devices demands. The balun transmission line transformers
applied in push-pull amplifiers enable input/output impedance
transformation, but are mainly used to convert the balanced output
into unbalanced and the input unbalanced into balanced. A simple
and affordable alternative solution over the traditional coaxial
transformer is the coreless planar balun. A key advantage over the
traditional approach lies in the high specifications repeatability;
simplifying the amplifier construction requirements as the planar
balun constitutes an integrated part of the PCB copper layout. This
paper presents the performance analysis of a planar LDMOS
MRFE6VP5600 Push-Pull amplifier that enables robust operation in
Band III, DVB-T, DVB-T2 standards but functions equally well in
Band II, for DRM+ new generation transmitters.
Abstract: A phase diagram of the Ag2SO4 - CaSO4 (Silver sulphate – Calcium Sulphate) binaries system using conductivity, XRD (X-Ray Diffraction Technique) and DTA (Differential Thermal Analysis) data is constructed. The eutectic reaction (liquid -» a-Ag2SO4 + CaSO4) is observed at 10 mole% CaSO4 and 645°C. Room temperature solid solubility limit up to 5.27 mole % of Ca 2+ in Ag2SO4 is set using X-ray powder diffraction and scanning electron microscopy results. All compositions beyond this limit are two-phase mixtures below and above the transition temperature (≈ 416°C). The bulk conductivity, obtained following complex impedance spectroscopy, is found decreasing with increase in CaSO4 content. Amongst other binary compositions, the 80AgSO4-20CaSO4 gave improved sinterability/packing density.
Abstract: The passive electrical properties of a tissue depends
on the intrinsic constituents and its structure, therefore by measuring
the complex electrical impedance of the tissue it might be possible to
obtain indicators of the tissue state or physiological activity [1].
Complete bio-impedance information relative to physiology and
pathology of a human body and functional states of the body tissue or
organs can be extracted by using a technique containing a fourelectrode
measurement setup. This work presents the estimation
measurement setup based on the four-electrode technique. First, the
complex impedance is estimated by three different estimation
techniques: Fourier, Sine Correlation and Digital De-convolution and
then estimation errors for the magnitude, phase, reactance and
resistance are calculated and analyzed for different levels of
disturbances in the observations. The absolute values of relative
errors are plotted and the graphical performance of each technique is
compared.