Abstract: In addition to kidney transplant, renal replacement therapy involves hemodialysis and peritoneal dialysis (PD). PD possesses advantages such as maintaining stable physiological blood status and blood pressure, alleviating anemia, and improving mobility, which make it an ideal method for at-home dialysis treatment. However, potential danger still exists despite the numerous advantages of PD, particularly when patients require dialysis exchange four to five times a day, during which improper operation can easily lead to peritonitis. The process of draining and filling is called an exchange and takes about 30 to 40 minutes. Connecting the transfer set requires sterile technique. Transfer set may require a new cap each time that it disconnects from the bag after an exchange. There are many chances to get infection due to unsafe behavior (ex: hand tremor, poor eyesight and weakness, cap fall-down). The proposed semi-automatic connection mechanism used in the PD can greatly reduce infection chances. This light-weight connection device is portable. The device also does not require using throughout the entire process. It is capable of significantly improving quality of life. Therefore, it is very promising to adopt in home care application.
Abstract: In this work, the hemodynamics in the sinuses of
Valsalva after Transcatheter Aortic Valve Implantation is numerically
examined. We focus on the physical results in the two-dimensional
case. We use a finite element methodology based on a Lagrange
multiplier technique that enables to couple the dynamics of blood
flow and the leaflets’ movement. A massively parallel implementation
of a monolithic and fully implicit solver allows more accuracy and
significant computational savings. The elastic properties of the aortic
valve are disregarded, and the numerical computations are performed
under physiologically correct pressure loads. Computational results
depict that blood flow may be subject to stagnation in the lower
domain of the sinuses of Valsalva after Transcatheter Aortic Valve
Implantation.
Abstract: This paper is concerned with microwave (MW) ablation for a liver cancer tissue by using helix antenna. The antenna structure supports the propagation of microwave energy at 2.45 GHz. A 1½ turn spiral catheter-based microwave antenna applicator has been developed. We utilize the three-dimensional finite element method (3D FEM) simulation to analyze where the tissue heat flux, lesion pattern and volume destruction during MW ablation. The configurations of helix antenna where Helix air-core antenna and Helix Dielectric-core antenna. The 3D FEMs solutions were based on Maxwell and bio-heat equations. The simulation protocol was power control (10 W, 300s). Our simulation result, both helix antennas have heat flux occurred around the helix antenna and that can be induced the temperature distribution similar (teardrop). The region where the temperature exceeds 50°C the microwave ablation was successful (i.e. complete destruction). The Helix air-core antenna and Helix Dielectric-core antenna, ablation zone or axial ratios (Widest/length) were respectively 0.82 and 0.85; the complete destructions were respectively 4.18 cm3 and 5.64 cm3
Abstract: It has been proven that early establishment of
microbial flora in digestive tract of ruminants, has a beneficial effect
on their health condition and productivity. A probiotic compound,
made from five bacteria isolated from adult bovine cattle, was dosed
to 15 Holstein newborn calves in order to measure its capacity of
improving body weight gain and reduce diarrhea incidence. The test
was performed in the municipality of Cajicá (Colombia), at 2580
m.a.s.l., throughout rainy season, with environmental temperature
that oscillated between 4 to 25 °C. Five calves were allotted to
control (no addition of probiotic). Treatments 1, and 2 (5 calves per
group) received 10 ml Probiotic mix 1 and 2, respectively. Probiotic
mixes 1 and 2 where similar in microbial composition but different in
production process. Probiotics were added to the morning milk and
dosed on a daily basis by a month and then on a weekly basis for
three additional months. Diarrhea incidence was measured by
observance of number of animals affected in each group; each animal
was weighed up on a daily basis for obtaining weight gain and rumen
fluid samples were extracted with oro-esophageal catheter for
determining level of fiber and grain consumption.
Abstract: Urinary Tract Infections (UTI) account for an estimated 25-40% nosocomial infection, out of which 90% are associated with urinary catheter, called Catheter associated urinary tract infection (CAUTI). The microbial populations within CAUTI frequently develop as biofilms. In the present study, microbial contamination of indwelling urinary catheters was investigated. Biofilm forming ability of the isolates was determined by tissue culture plate method. Prevention of biofilm formation in the urinary catheter by Pseudomonas aeruginosa was also determined by coating the catheter with some enzymes, gentamycin and EDTA. It was found that 64% of the urinary catheters get contaminated during the course of catheterization. Of the total 6 isolates, biofilm formation was seen in 100% Pseudomonas aeruginosa and E. coli, 90% in Enterococci, 80% in Klebsiella and 66% in S. aureus. It was noted that the biofilm production by Pseudomonas was prolonged by 7 days in amylase, 8 days in protease, 6 days in lysozyme, 7days in gentamycin and 5 days in EDTA treated catheter.