Abstract: Internal insulation of external walls is often problematic due to increased moisture content in the wall and interstitial or surface condensation risk. In this paper, the hygrothermal performance of prefabricated, concrete, large panel, external wall typical for WK70 system, commonly used in Poland in the 70’s, with inside, additional insulation was investigated. Thermal insulation board made out of hygroscopic, natural materials with moisture buffer capacity and extruded polystyrene (EPS) board was used as interior insulation. Experience with this natural insulation is rare in Poland. The analysis was performed using WUFI software. First of all, the impact of various standard boundary conditions on the behavior of the different wall assemblies was tested. The comparison of results showed that the moisture class according to the EN ISO 13788 leads to too high values of total moisture content in the wall since the boundary condition according to the EN 15026 should be usually applied. Then, hygrothermal 1D-simulations were conducted by WUFI Pro for analysis of internally added insulation, and the weak point like the joint of the wall with the concrete ceiling was verified using 2D simulations. Results showed that, in the Warsaw climate and the indoor conditions adopted in accordance with EN 15026, in the tested wall assemblies, regardless of the type of interior insulation, there would not be any problems with moisture - inside the structure and on the interior surface.
Abstract: This paper reports on the performance of deliberately unbalanced, reliable, non-automated and assembly lines that merge, whose workstations differ in terms of their mean operation times. Simulations are carried out on 5- and 8-station lines with 1, 2 and 4 buffer capacity units, % degrees of line imbalance of 2, 5 and 12, and 24 different patterns of means imbalance. Data on two performance measures, namely throughput and average buffer level were gathered, statistically analysed and compared to a merging balanced line counterpart. It was found that the best configurations are a balanced line arrangement and a monotone decreasing order for each of the parallel merging lines, with the first generally resulting in a lower throughput and the second leading to a lower average buffer level than those of a balanced line.
Abstract: With demand for primary energy continuously
growing, search for renewable and efficient energy sources has been
high on agenda of our society. One of the most promising energy
sources is biogas technology. Residues coming from dairy industry
and milk processing could be used in biogas production; however,
low efficiency and high cost impede wide application of such
technology. One of the main problems is management and conversion
of organic residues through the anaerobic digestion process which is
characterized by acidic environment due to the low whey pH (
Abstract: This work focuses on the remediation of polycyclic
aromatic hydrocarbons (PAHs)-contaminated soil via Fenton
treatment coupled with novel chelating agent (CA). The feasibility of
chelated modified Fenton (MF) treatment to promote PAH oxidation
in artificially contaminated soils was investigated in laboratory scale
batch experiments at natural pH. The effects of adding inorganic and
organic CA are discussed. Experiments using different iron catalyst
to CA ratios were conducted, resulting in hydrogen peroxide: soil:
iron: CA weight ratios that varied from 0.049: 1: 0.072: 0.008 to
0.049: 1: 0.072: 0.067. The results revealed that (1) inorganic CA
could provide much higher PAH removal efficiency and (2) most of
the proposed CAs were more efficient than commonly utilised CAs
even at mild ratio. This work highlights the potential of novel
chelating agents in maintaining a suitable environment throughout
the Fenton treatment, particularly in soils with high buffer capacity.