Abstract: Since the actuator capacity is limited, in the real
application of active control systems under sever earthquakes it is
conceivable that the actuators saturate, hence the actuator saturation
should be considered as a constraint in design of optimal controllers.
In this paper optimal design of active controllers for nonlinear
structures by considering actuator saturation, has been studied. The
proposed method for designing optimal controllers is based on
defining an optimization problem which the objective has been to
minimize the maximum displacement of structure when a limited
capacity for actuator has been used. To this end a single degree of
freedom (SDF) structure with a bilinear hysteretic behavior has been
simulated under a white noise ground acceleration of different
amplitudes. Active tendon control mechanism, comprised of prestressed
tendons and an actuator, and extended nonlinear Newmark
method based instantaneous optimal control algorithm have been
used. To achieve the best results, the weights corresponding to
displacement, velocity, acceleration and control force in the
performance index have been optimized by the Distributed Genetic
Algorithm (DGA). Results show the effectiveness of the proposed
method in considering actuator saturation. Also based on the
numerical simulations it can be concluded that the actuator capacity
and the average value of required control force are two important
factors in designing nonlinear controllers which consider the actuator
saturation.
Abstract: The study of human hand morphology reveals that developing an artificial hand with the capabilities of human hand is an extremely challenging task. This paper presents the development of a robotic prosthetic hand focusing on the improvement of a tendon driven mechanism towards a biomimetic prosthetic hand. The design of this prosthesis hand is geared towards achieving high level of dexterity and anthropomorphism by means of a new hybrid mechanism that integrates a miniature motor driven actuation mechanism, a Shape Memory Alloy actuated mechanism and a passive mechanical linkage. The synergy of these actuators enables the flexion-extension movement at each of the finger joints within a limited size, shape and weight constraints. Tactile sensors are integrated on the finger tips and the finger phalanges area. This prosthesis hand is developed with an exact size ratio that mimics a biological hand. Its behavior resembles the human counterpart in terms of working envelope, speed and torque, and thus resembles both the key physical features and the grasping functionality of an adult hand.
Abstract: Even it has been recognized that Shape Memory
Alloys (SMA) have a significant potential for deployment actuators,
the number of applications of SMA-based actuators to the present
day is still quite small, due to the need of deep understanding of the
thermo-mechanical behavior of SMA, causing an important need for
a mathematical model able to describe all thermo-mechanical
properties of SMA by relatively simple final set of constitutive
equations. SMAs offer attractive potentials such as: reversible strains
of several percent, generation of high recovery stresses and high
power / weight ratios. The paper tries to provide an overview of the
shape memory functions and a presentation of the designed and
developed temperature control system used for a gripper actuated by
two pairs of differential SMA active springs. An experimental setup
was established, using electrical energy for actuator-s springs heating
process. As for holding the temperature of the SMA springs at certain
level for a long time was developed a control system in order to
avoid the active elements overheating.
Abstract: In this paper, the modified optimal sliding mode control with a proposed method to design a sliding surface is presented. Because of the inability of the previous approach of the sliding mode method to design a bounded and suitable input, the new variation is proposed in the sliding manifold to obviate problems in a structural system. Although the sliding mode control is a powerful method to reject disturbances and noises, the chattering problem is not good for actuators. To decrease the chattering phenomena, the optimal control is added to the sliding mode control. Not only the proposed method can decline the intense variations in the inputs of the system but also it can produce the efficient responses respect to the sliding mode control and optimal control that are shown by performing some numerical simulations.
Abstract: In this paper, we propose a hardware and software
design method for automotive Electronic Control Units (ECU)
considering the functional safety. The proposed ECU is considered for
the application to Electro-Mechanical Actuator systems and the
validity of the design method is shown by the application to the
Electro-Mechanical Brake (EMB) control system which is used as a
brake actuator in Brake-By-Wire (BBW) systems. The importance of a
functional safety-based design approach to EMB ECU design has been
emphasized because of its safety-critical functions, which are executed
with the aid of many electric actuators, sensors, and application
software. Based on hazard analysis and risk assessment according to
ISO26262, the EMB system should be ASIL-D-compliant, the highest
ASIL level. To this end, an external signature watchdog and an
Infineon 32-bit microcontroller TriCore are used to reduce risks
considering common-cause hardware failure. Moreover, a software
design method is introduced for implementing functional
safety-oriented monitoring functions based on an asymmetric dual
core architecture considering redundancy and diversity. The validity
of the proposed ECU design approach is verified by using the EMB
Hardware-In-the-Loop (HILS) system, which consists of the EMB
assembly, actuator ECU, a host PC, and a few debugging devices.
Furthermore, it is shown that the existing sensor fault tolerant control
system can be used more effectively for mitigating the effects of
hardware and software faults by applying the proposed ECU design
method.
Abstract: This paper details few mechanical modeling and
design issues of RF MEMS switches. We concentrate on an
electrostatically actuated broad side series switch; surface
micromachined with a crab leg membrane. The same results are
extended to any complex structure. With available experimental data
and fabrication results, we present the variation in dynamic
performance and compliance of the switch with reference to few
design issues, which we find are critical in deciding the dynamic
behavior of the switch, without compromise on the RF
characteristics. The optimization of pull in voltage, transient time and
resonant frequency with regard to these critical design parameters are
also presented.
Abstract: This paper presents a new type of mechanism and trajectory planning strategy for bipedal walking robot. The newly designed mechanism is able to improve the performance of bipedal walking robot in terms of energy efficiency and weight reduction by utilizing minimum number of actuators. The usage of parallelogram mechanism eliminates the needs of having an extra actuator at the knee joint. This mechanism works together with the joint space trajectory planning in order to realize straight legged walking which cannot be achieved by conventional inverse kinematics trajectory planning due to the singularity. The effectiveness of the proposed strategy is confirmed by computer simulation results.
Abstract: Due to their high power-to-weight ratio and low cost, pneumatic actuators are attractive for robotics and automation applications; however, achieving fast and accurate control of their position have been known as a complex control problem. The paper presents a methodology for obtaining controllers that achieve high position accuracy and preserve the closed-loop characteristics over a broad operating range. Experimentation with a number of conventional (or "classical") three-term controllers shows that, as repeated operations accumulate, the characteristics of the pneumatic actuator change requiring frequent re-tuning of the controller parameters (PID gains). Furthermore, three-term controllers are found to perform poorly in recovering the closed-loop system after the application of load or other external disturbances. The key reason for these problems lies in the non-linear exchange of energy inside the cylinder relating, in particular, to the complex friction forces that develop on the piston-wall interface. In order to overcome this problem but still remain within the boundaries of classical control methods, we designed an auto selective classicaql controller so that the system performance would benefit from all three control gains (KP, Kd, Ki) according to system requirements and the characteristics of each type of controller. This challenging experimentation took place for consistent performance in the face of modelling imprecision and disturbances. In the work presented, a selective PID controller is presented for an experimental rig comprising an air cylinder driven by a variable-opening pneumatic valve and equipped with position and pressure sensors. The paper reports on tests carried out to investigate the capability of this specific controller to achieve consistent control performance under, repeated operations and other changes in operating conditions.
Abstract: The blood ducts must be occluded to avoid loss of
blood from vessels in laparoscopic surgeries. This paper presents a
locking mechanism to be used in a ligation laparoscopic procedure
(LigLAP I), as an alternative solution for a stapling procedure.
Currently, stapling devices are being used to occlude vessels. Using
these devices may result in some problems, including injury of bile
duct, taking up a great deal of space behind the vessel, and bile leak.
In this new procedure, a two-layer suture occludes a vessel. A
locking mechanism is also required to hold the suture. Since there is
a limited space at the device tip, a Shape Memory Alloy (SMA)
actuator is used in this mechanism. Suitability for cleanroom
applications, small size, and silent performance are among the
advantages of SMA actuators in biomedical applications. An
experimental study is conducted to examine the function of the
locking mechanism. To set up the experiment, a prototype of a
locking mechanism is built using nitinol, which is a nickel-titanium
shape memory alloy. The locking mechanism successfully locks a
polymer suture for all runs of the experiment. In addition, the effects
of various surface materials on the applied pulling forces are studied.
Various materials are mounted at the mechanism tip to compare the
maximum pulling forces applied to the suture for each material. The
results show that the various surface materials on the device tip
provide large differences in the applied pulling forces.
Abstract: A multivariable discontinuous feedback linearization approach is proposed to position control of an electrically driven fast robot manipulator. A desired performance is achieved by selecting a useful controller and suitable sampling rate and considering saturation for actuators. There is a high flexibility to apply the proposed control approach on different electrically driven manipulators. The control approach can guarantee the stability and satisfactory tracking performance. A PUMA 560 robot driven by geared permanent magnet dc motors is simulated. The simulation results show a desired performance for control system under technical specifications.