Abstract: It is essential to have a uniform and calm flow field
for a settling tank to have high performance. In general, the
recirculation zones always occurred in sedimentation tanks. The
presence of these regions may have different effects. The nonuniformity
of the velocity field, the short-circuiting at the surface and
the motion of the jet at the bed of the tank that occurs because of the
recirculation in the sedimentation layer, are affected by the geometry
of the tank. There are some ways to decrease the size of these dead
zones, which would increase the performance. One of the ways is to
use a suitable baffle configuration. In this study, the presence of
baffle with different position has been investigated by a finite volume
method, with VOF (Volume of Fluid) model. Besides, the k-ε
turbulence model is used in the numerical calculations. The results
indicate that the best position of the baffle is obtained when the
volume of the recirculation region is minimized or is divided to
smaller part and the flow field trend to be uniform in the settling
zone.
Abstract: A new conserving approach in the context of Immersed Boundary Method (IBM) is presented to simulate one dimensional, incompressible flow in a moving boundary problem. The method employs control volume scheme to simulate the flow field. The concept of ghost node is used at the boundaries to conserve the mass and momentum equations. The Present method implements the conservation laws in all cells including boundary control volumes. Application of the method is studied in a test case with moving boundary. Comparison between the results of this new method and a sharp interface (Image Point Method) IBM algorithm shows a well distinguished improvement in both pressure and velocity fields of the present method. Fluctuations in pressure field are fully resolved in this proposed method. This approach expands the IBM capability to simulate flow field for variety of problems by implementing conservation laws in a fully Cartesian grid compared to other conserving methods.
Abstract: The operation performance of a valveless micro-pump
is strongly dependent on the shape of connected nozzle/diffuser and
Reynolds number. The aims of present work are to compare the
performance curves of micropump with the original straight
nozzle/diffuser and contoured nozzle/diffuser under different back
pressure conditions. The tested valveless micropumps are assembled
of five pieces of patterned PMMA plates with hot-embracing
technique. The structures of central chamber, the inlet/outlet
reservoirs and the connected nozzle/diffuser are fabricated with laser
cutting machine. The micropump is actuated with circular-type PZT
film embraced on the bottom of central chamber. The deformation of
PZT membrane with various input voltages is measured with a
displacement laser probe. A simple testing facility is also constructed
to evaluate the performance curves for comparison.
In order to observe the evaluation of low Reynolds number
multiple vortex flow patterns within the micropump during suction
and pumping modes, the unsteady, incompressible laminar
three-dimensional Reynolds-averaged Navier-Stokes equations are
solved. The working fluid is DI water with constant thermo-physical
properties. The oscillating behavior of PZT film is modeled with the
moving boundary wall in way of UDF program. With the dynamic
mesh method, the instants pressure and velocity fields are obtained
and discussed.Results indicated that the volume flow rate is not
monotony increased with the oscillating frequency of PZT film,
regardless of the shapes of nozzle/diffuser. The present micropump
can generate the maximum volume flow rate of 13.53 ml/min when
the operation frequency is 64Hz and the input voltage is 140 volts.
The micropump with contoured nozzle/diffuser can provide 7ml/min
flow rate even when the back pressure is up to 400 mm-H2O. CFD
results revealed that the flow central chamber was occupied with
multiple pairs of counter-rotating vortices during suction and
pumping modes. The net volume flow rate over a complete
oscillating periodic of PZT
Abstract: Cardiovascular diseases, principally atherosclerosis, are responsible for 30% of world deaths. Atherosclerosis is due to the formation of plaque. The fatty plaque may be at risk of rupture, leading typically to stroke and heart attack. The plaque is usually associated with a high degree of lumen reduction, called a stenosis.It is increasingly recognized that the initiation and progression of disease and the occurrence of clinical events is a complex interplay between the local biomechanical environment and the local vascular biology. The aim of this study is to investigate the flow behavior through a stenosed artery. A physical experiment was performed using an artery model and blood analogue fluid. An axisymmetric model constructed consists of contraction and expansion region that follow a mathematical form of cosine function. A 30% diameter reduction was used in this study. The flow field was measured using particle image velocimetry (PIV). Spherical particles with 20μm diameter were seeded in a water-glycerol-NaCl mixture. Steady flow Reynolds numbers are 250. The area of interest is the region after the stenosis where the flow separation occurs. The velocity field was measured and the velocity gradient was investigated. There was high particle concentration in the recirculation zone. High velocity gradient formed immediately after the stenosis throat created a lift force that enhanced particle migration to the flow separation area.
Abstract: This paper deals with the helical flow of a Newtonian
fluid in an infinite circular cylinder, due to both longitudinal and
rotational shear stress. The velocity field and the resulting shear
stress are determined by means of the Laplace and finite Hankel
transforms and satisfy all imposed initial and boundary conditions.
For large times, these solutions reduce to the well-known steady-state
solutions.
Abstract: The presented article deals with the description of a
numerical model of a corridor at a Central Interim Spent Fuel Storage
Facility (hereinafter CISFSF). The model takes into account the
effect of air flows on the temperature of stored waste. The
computational model was implemented in the ANSYS/CFX
programming environment in the form of a CFD task solution, which
was compared with an approximate analytical calculation. The article
includes a categorization of the individual alternatives for the
ventilation of such underground systems. The aim was to evaluate a
ventilation system for a CISFSF with regard to its stability and
capacity to provide sufficient ventilation for the removal of heat
produced by stored casks with spent nuclear fuel.
Abstract: Circular tubes have been widely used as structural
members in engineering application. Therefore, its collapse behavior
has been studied for many decades, focusing on its energy absorption
characteristics. In order to predict the collapse behavior of members,
one could rely on the use of finite element codes or experiments.
These tools are helpful and high accuracy but costly and require
extensive running time. Therefore, an approximating model of tubes
collapse mechanism is an alternative for early step of design. This
paper is also aimed to develop a closed-form solution of thin-walled
circular tube subjected to bending. It has extended the Elchalakani et
al.-s model (Int. J. Mech. Sci.2002; 44:1117-1143) to include the
rate of energy dissipation of rolling hinge in the circumferential
direction. The 3-D geometrical collapse mechanism was analyzed by
adding the oblique hinge lines along the longitudinal tube within the
length of plastically deforming zone. The model was based on the
principal of energy rate conservation. Therefore, the rates of internal
energy dissipation were calculated for each hinge lines which are
defined in term of velocity field. Inextensional deformation and
perfect plastic material behavior was assumed in the derivation of
deformation energy rate. The analytical result was compared with
experimental result. The experiment was conducted with a number of
tubes having various D/t ratios. Good agreement between analytical
and experiment was achieved.
Abstract: The flow of a third grade fluid in an orthogonal rheometer is studied. We employ the admissible velocity field proposed in [5]. We solve the problem and obtain the velocity field as well as the components for the Cauchy tensor. We compare the results with those from [9]. Some diagrams concerning the velocity and Cauchy stress components profiles are presented for different values of material constants and compared with the corresponding values for a linear viscous fluid.
Abstract: Phase-Contrast MR imaging methods are widely used
for measurement of blood flow velocity components. Also there are
some other tools such as CT and Ultrasound for velocity map
detection in intravascular studies. These data are used in deriving
flow characteristics. Some clinical applications are investigated
which use pressure distribution in diagnosis of intravascular disorders
such as vascular stenosis. In this paper an approach to the problem of
measurement of intravascular pressure field by using velocity field
obtained from flow images is proposed. The method presented in this
paper uses an algorithm to calculate nonlinear equations of Navier-
Stokes, assuming blood as an incompressible and Newtonian fluid.
Flow images usually suffer the lack of spatial resolution. Our
attempt is to consider the effect of spatial resolution on the pressure
distribution estimated from this method. In order to achieve this aim,
velocity map of a numerical phantom is derived at six different
spatial resolutions. To determine the effects of vascular stenoses on
pressure distribution, a stenotic phantom geometry is considered. A
comparison between the pressure distribution obtained from the
phantom and the pressure resulted from the algorithm is presented. In
this regard we also compared the effects of collocated and staggered
computational grids on the pressure distribution resulted from this
algorithm.