Abstract: A compact Ultra Wide Band (UWB) antenna with coplanar
waveguide feed has been designed and results are verified in
this paper. The antenna has been designed on FR4 substrate with
dielectric constant (εr) of 4.4 and dimensions of 32mm x 26mm x
0.8mm. The presented antenna shows return loss characteristics in the
band of 3.1 to 10.6 GHz as prescribed by FCC, USA. Parametric
studies have been done and results thus obtained have been
presented. Simulated results have been verified on Rohde & Swartz
VNA. The measured results are in good agreement with simulated
results which make the presented antenna suitable to be used for
wearable applications. Performance analysis of antenna has also been
shown in the presence of three layered Human Arm model. Results
obtained in presence of Human Arm model has been compared with
that in free space.
Abstract: UWB is a very attractive technology for many
applications. It provides many advantages such as fine resolution and high power efficiency. Our interest in the current study is the use of
UWB radar technique in microwave medical imaging systems, especially for early breast cancer detection. The Federal Communications Commission FCC allowed frequency bandwidth of
3.1 to 10.6 GHz for this purpose. In this paper we suggest an UWB Bowtie slot antenna with enhanced bandwidth. Effects of varying the geometry of the antenna
on its performance and bandwidth are studied. The proposed antenna
is simulated in CST Microwave Studio. Details of antenna design and
simulation results such as return loss and radiation patterns are discussed in this paper. The final antenna structure exhibits good
UWB characteristics and has surpassed the bandwidth requirements.
Abstract: In this paper a tuning fork type structure of Ultra
Wideband (UWB) antenna is proposed. The antenna offers excellent
performance for UWB system, ranging from 3.7 GHz to 13.8 GHz.
The antenna exhibits a 10 dB return loss bandwidth over the entire
frequency band. The rectangular patch antenna is designed on FR4
substrate and fed with 50 ohms microstrip line by optimizing the
width of partial ground, the width and position of the feedline to
operate in UWB. The rectangular patch is then modified to tuning
fork structure by maintaining UWB frequency range.