Abstract: A reliable, real-time, and non-invasive system that can identify patients at risk for hemodynamic instability is needed to aid clinicians in their efforts to anticipate patient deterioration and initiate early interventions. The purpose of this pilot study was to explore the clinical capabilities of a real-time analytic from a single lead of an electrocardiograph to correctly distinguish between rapid response team (RRT) activations due to hemodynamic (H-RRT) and non-hemodynamic (NH-RRT) causes, as well as predict H-RRT cases with actionable lead times. The study consisted of a single center, retrospective cohort of 21 patients with RRT activations from step-down and telemetry units. Through electronic health record review and blinded to the analytic’s output, each patient was categorized by clinicians into H-RRT and NH-RRT cases. The analytic output and the categorization were compared. The prediction lead time prior to the RRT call was calculated. The analytic correctly distinguished between H-RRT and NH-RRT cases with 100% accuracy, demonstrating 100% positive and negative predictive values, and 100% sensitivity and specificity. In H-RRT cases, the analytic detected hemodynamic deterioration with a median lead time of 9.5 hours prior to the RRT call (range 14 minutes to 52 hours). The study demonstrates that an electrocardiogram (ECG) based analytic has the potential for providing clinical decision and monitoring support for caregivers to identify at risk patients within a clinically relevant timeframe allowing for increased vigilance and early interventional support to reduce the chances of continued patient deterioration.
Abstract: From several years till now the aerospace industry is developing more and more small satellites for Low-Earth Orbit (LEO) missions. Such satellites have a low cost of making and launching since they have a size and weight smaller than other types of satellites. However, because of size limitations, small satellites need integrated electronic equipment based on digital logic. Moreover, the LEOs require telecommunication modules with high throughput to transmit to earth a big amount of data in a short time. In order to meet such requirements, in this paper we propose a Telemetry, Tracking & Command module optimized through the use of the Commercial Off-The-Shelf components. The proposed approach exploits the major flexibility offered by these components in reducing costs and optimizing the performance. The method has been applied in detail for the design of the front-end receiver, which has a low noise figure (1.5 dB) and DC power consumption (smaller than 2 W). Such a performance is particularly attractive since it allows fulfilling the energy budget stringent constraints that are typical for LEO small platforms.
Abstract: Many organizations are faced with the challenge of how to analyze and build Machine Learning models using their sensitive telemetry data. In this paper, we discuss how users can leverage the power of R without having to move their big data around as well as a cloud based solution for organizations willing to host their data in the cloud. By using ScaleR technology to benefit from parallelization and remote computing or R Services on premise or in the cloud, users can leverage the power of R at scale without having to move their data around.
Abstract: The current state-of-the-art methods of mass gauging of Electric Propulsion (EP) propellants in microgravity conditions rely on external measurements that are taken at the surface of the tank. The tanks are operated under a constant thermal duty cycle to store the propellant within a pre-defined temperature and pressure range. We demonstrate using computational fluid dynamics (CFD) simulations that the heat-transfer within the pressurized propellant generates temperature and density anisotropies. This challenges the standard mass gauging methods that rely on the use of time changing skin-temperatures and pressures. We observe that the domes of the tanks are prone to be overheated, and that a long time after the heaters of the thermal cycle are switched off, the system reaches a quasi-equilibrium state with a more uniform density. We propose a new gauging method, which we call the Improved PVT method, based on universal physics and thermodynamics principles, existing TRL-9 technology and telemetry data. This method only uses as inputs the temperature and pressure readings of sensors externally attached to the tank. These sensors can operate during the nominal thermal duty cycle. The improved PVT method shows little sensitivity to the pressure sensor drifts which are critical towards the end-of-life of the missions, as well as little sensitivity to systematic temperature errors. The retrieval method has been validated experimentally with CO2 in gas and fluid state in a chamber that operates up to 82 bar within a nominal thermal cycle of 38 °C to 42 °C. The mass gauging error is shown to be lower than 1% the mass at the beginning of life, assuming an initial tank load at 100 bar. In particular, for a pressure of about 70 bar, just below the critical pressure of CO2, the error of the mass gauging in gas phase goes down to 0.1% and for 77 bar, just above the critical point, the error of the mass gauging of the liquid phase is 0.6% of initial tank load. This gauging method improves by a factor of 8 the accuracy of the standard PVT retrievals using look-up tables with tabulated data from the National Institute of Standards and Technology.
Abstract: This paper presents a digital non-linear pulse-width modulation (PWM) controller in a high-voltage (HV) buck-boost DC-DC converter for the piezoelectric transducer of the down-hole acoustic telemetry system. The proposed design controls the generation of output signal with voltage higher than the supply voltage and is targeted to work under high temperature. To minimize the power consumption and silicon area, a simple and efficient design scheme is employed to develop the PWM controller. The proposed PWM controller consists of serial to parallel (S2P) converter, data assign block, a mode and duty cycle controller (MDC), linearly PWM (LPWM) and noise shaper, pulse generator and clock generator. To improve the reliability of circuit operation at higher temperature, this design is fabricated with the 1.0-μm silicon-on-insulator (SOI) CMOS process. The implementation results validated that the proposed design has the advantages of smaller size, lower power consumption and robust thermal stability.
Abstract: The aim of this research paper is to conceptualize, discuss, analyze and propose alternate design methodologies for futuristic Black Box for flight safety. The proposal also includes global networking concepts for real time surveillance and monitoring of flight performance parameters including GPS parameters. It is expected that this proposal will serve as a failsafe real time diagnostic tool for accident investigation and location of debris in real time. In this paper, an attempt is made to improve the existing methods of flight data recording techniques and improve upon design considerations for futuristic FDR to overcome the trauma of not able to locate the block box. Since modern day communications and information technologies with large bandwidth are available coupled with faster computer processing techniques, the attempt made in this paper to develop a failsafe recording technique is feasible. Further data fusion/data warehousing technologies are available for exploitation.
Abstract: The critical concern of satellite operations is to ensure
the health and safety of satellites. The worst case in this perspective
is probably the loss of a mission, but the more common interruption
of satellite functionality can result in compromised mission
objectives. All the data acquiring from the spacecraft are known as
Telemetry (TM), which contains the wealth information related to the
health of all its subsystems. Each single item of information is
contained in a telemetry parameter, which represents a time-variant
property (i.e. a status or a measurement) to be checked. As a
consequence, there is a continuous improvement of TM monitoring
systems to reduce the time required to respond to changes in a
satellite's state of health. A fast conception of the current state of the
satellite is thus very important to respond to occurring failures.
Statistical multivariate latent techniques are one of the vital learning
tools that are used to tackle the problem above coherently.
Information extraction from such rich data sources using advanced
statistical methodologies is a challenging task due to the massive
volume of data. To solve this problem, in this paper, we present a
proposed unsupervised learning algorithm based on Principle
Component Analysis (PCA) technique. The algorithm is particularly
applied on an actual remote sensing spacecraft. Data from the
Attitude Determination and Control System (ADCS) was acquired
under two operation conditions: normal and faulty states. The models
were built and tested under these conditions, and the results show that
the algorithm could successfully differentiate between these
operations conditions. Furthermore, the algorithm provides
competent information in prediction as well as adding more insight
and physical interpretation to the ADCS operation.
Abstract: In this paper, we present a four-step ortho-rectification
procedure for real-time geo-referencing of video data from a low-cost
UAV equipped with a multi-sensor system. The basic procedures for
the real-time ortho-rectification are: (1) decompilation of the video
stream into individual frames; (2) establishing the interior camera
orientation parameters; (3) determining the relative orientation
parameters for each video frame with respect to each other; (4)
finding the absolute orientation parameters, using a self-calibration
bundle and adjustment with the aid of a mathematical model. Each
ortho-rectified video frame is then mosaicked together to produce a
mosaic image of the test area, which is then merged with a well
referenced existing digital map for the purpose of geo-referencing
and aerial surveillance. A test field located in Abuja, Nigeria was
used to evaluate our method. Video and telemetry data were collected
for about fifteen minutes, and they were processed using the four-step
ortho-rectification procedure. The results demonstrated that the
geometric measurement of the control field from ortho-images is
more accurate when compared with those from original perspective
images when used to pin point the exact location of targets on the
video imagery acquired by the UAV. The 2-D planimetric accuracy
when compared with the 6 control points measured by a GPS receiver
is between 3 to 5 metres.
Abstract: This paper discusses the approach of real-time
controlling of the energy management system using the data
acquisition tool of LabVIEW. The main idea of this inspiration was
to interface the Station (PC) with the system and publish the data on
internet using LabVIEW. In this venture, controlling and switching of
3 phase AC loads are effectively and efficiently done. The phases are
also sensed through devices. In case of any failure the attached
generator starts functioning automatically. The computer sends
command to the system and system respond to the request. The
modern feature is to access and control the system world-wide using
world wide web (internet). This controlling can be done at any time
from anywhere to effectively use the energy especially in developing
countries where energy management is a big problem. In this system
totally integrated devices are used to operate via remote location.
Abstract: The technological concepts such as wireless hospital
and portable cardiac telemetry system require the development of
physiological signal acquisition devices to be easily integrated into
the hospital database. In this paper we present the low cost, portable
wireless ECG acquisition hardware that transmits ECG signals to a
dedicated computer.The front end of the system obtains and
processes incoming signals, which are then transmitted via a
microcontroller and wireless Bluetooth module. A monitoring
purpose Bluetooth based end user application integrated with patient
database management module is developed for the computers. The
system will act as a continuous event recorder, which can be used to
follow up patients who have been resuscitatedfrom cardiac arrest,
ventricular tachycardia but also for diagnostic purposes for patients
with arrhythmia symptoms. In addition, cardiac information can be
saved into the patient-s database of the hospital.
Abstract: As the increase of intraoral acidity due to ingestion of sweet foods and acidic beverages usually bring forth a dental caries and a erosion, the measurement of intraoral pH is essential in the study of oral environment. The indwelling intraoral pH telemetry for lasting longer than 24 hours in the mouth was developed to overcome the limits of conventional wire electrode method previously used for salivary and plaque pH measurement, and to assess its effectiveness.