Abstract: The join dependency provides the basis for obtaining
lossless join decomposition in a classical relational schema. The
existence of Join dependency shows that that the tables always
represent the correct data after being joined. Since the classical
relational databases cannot handle imprecise data, they were
extended to fuzzy relational databases so that uncertain, ambiguous,
imprecise and partially known information can also be stored in
databases in a formal way. However like classical databases, the
fuzzy relational databases also undergoes decomposition during
normalization, the issue of joining the decomposed fuzzy relations
remains intact. Our effort in the present paper is to emphasize on this
issue. In this paper we define fuzzy join dependency in the
framework of type-1 fuzzy relational databases & type-2 fuzzy
relational databases using the concept of fuzzy equality which is
defined using fuzzy functions. We use the fuzzy equi-join operator
for computing the fuzzy equality of two attribute values. We also
discuss the dependency preservation property on execution of this
fuzzy equi- join and derive the necessary condition for the fuzzy
functional dependencies to be preserved on joining the decomposed
fuzzy relations. We also derive the conditions for fuzzy join
dependency to exist in context of both type-1 and type-2 fuzzy
relational databases. We find that unlike the classical relational
databases even the existence of a trivial join dependency does not
ensure lossless join decomposition in type-2 fuzzy relational
databases. Finally we derive the conditions for the fuzzy equality to
be non zero and the qualification of an attribute for fuzzy key.
Abstract: The aim of this paper is to present a new method
which can be used for progressive transmission of electrocardiogram
(ECG). The idea consists in transforming any ECG signal to an
image, containing one beat in each row. In the first step, the beats are
synchronized in order to reduce the high frequencies due to inter-beat
transitions. The obtained image is then transformed using a discrete
version of Radon Transform (DRT). Hence, transmitting the ECG,
leads to transmit the most significant energy of the transformed
image in Radon domain. For decoding purpose, the receptor needs to
use the inverse Radon Transform as well as the two synchronization
frames.
The presented protocol can be adapted for lossy to lossless
compression systems. In lossy mode we show that the compression
ratio can be multiplied by an average factor of 2 for an acceptable
quality of reconstructed signal. These results have been obtained on
real signals from MIT database.
Abstract: Extensive use of the Internet coupled with the
marvelous growth in e-commerce and m-commerce has created a
huge demand for information security. The Secure Socket Layer
(SSL) protocol is the most widely used security protocol in the
Internet which meets this demand. It provides protection against
eaves droppings, tampering and forgery. The cryptographic
algorithms RC4 and HMAC have been in use for achieving security
services like confidentiality and authentication in the SSL. But recent
attacks against RC4 and HMAC have raised questions in the
confidence on these algorithms. Hence two novel cryptographic
algorithms MAJE4 and MACJER-320 have been proposed as
substitutes for them. The focus of this work is to demonstrate the
performance of these new algorithms and suggest them as dependable
alternatives to satisfy the need of security services in SSL. The
performance evaluation has been done by using practical
implementation method.