Abstract: Cardiovascular diseases (CVDs) are the main cause of death globally. Most CVDs can be prevented by avoiding habitual risk factors. Separate from the habitual risk factors, there are some inherent factors in each individual that can increase the risk potential of CVDs. Vessel shapes and geometry are influential factors, having great impact on the blood flow and the hemodynamic behavior of the vessels. In the present study, the influence of bifurcation angle on blood flow characteristics is studied. In order to approach this topic, by simplifying the details of the bifurcation, three models with angles 30°, 45°, and 60° were created, then by using CFD analysis, the response of these models for stable flow and pulsatile flow was studied. In the conducted simulation in order to eliminate the influence of other geometrical factors, only the angle of the bifurcation was changed and other parameters remained constant during the research. Simulations are conducted under dynamic and stable condition. In the stable flow simulation, a steady velocity of 0.17 m/s at the inlet plug was maintained and in dynamic simulations, a typical LAD flow waveform is implemented. The results show that the bifurcation angle has an influence on the maximum speed of the flow. In the stable flow condition, increasing the angle lead to decrease the maximum flow velocity. In the dynamic flow simulations, increasing the bifurcation angle lead to an increase in the maximum velocity. Since blood flow has pulsatile characteristics, using a uniform velocity during the simulations can lead to a discrepancy between the actual results and the calculated results.
Abstract: An experimental study on finned-tube radiators has been conducted. Three radiators found in desktop computers sized for 120 mm fans were tested in steady and pulsatile flows of ambient air over a Reynolds number range of 50 < Re < 900. Water at 60 °C was circulated through the radiators to maintain a constant fin temperature during the tests. For steady flow, it was found that the heat transfer rate increased linearly with the mass flow rate of air. The pulsatile flow experiments showed that frequency of pulsation had a negligible effect on the heat transfer rate for the range of frequencies tested (0.5 Hz – 2.5 Hz). For all three radiators, the heat transfer rate was decreased in the case of pulsatile flow. Linear heat transfer correlations for steady and pulsatile flow were calculated in terms of Reynolds number and Nusselt number.
Abstract: The aim of the present study is to computationally evaluate the hemodynamic factors which affect the formation of atherosclerosis and plaque rupture in the human artery. An increase of atherosclerosis disease in the artery causes geometry changes, which results in hemodynamic changes such as flow separation, reattachment, and adhesion of new cells (chemotactic) in the artery. Hence, geometry plays an important role in the determining the nature of hemodynamic patterns. Influence of stenosis in the non-bifurcating artery, under pulsatile flow condition, has been studied on an idealized geometry. Analysis of flow through symmetric and asymmetric stenosis in the artery revealed the significance of oscillating shear index (OSI), flow separation, low WSS zones and secondary flow patterns on plaque formation. The observed characteristic of flow in the post-stenotic region highlight the importance of plaque eccentricity on the formation of secondary stenosis on the arterial wall.
Abstract: The exploitation of flow pulsation in micro- and
mini-channels is a potentially useful technique for enhancing cooling
of high-end photonics and electronics systems. It is thought that
pulsation alters the thickness of the hydrodynamic and thermal
boundary layers, and hence affects the overall thermal resistance
of the heat sink. Although the fluid mechanics and heat transfer
are inextricably linked, it can be useful to decouple the parameters
to better understand the mechanisms underlying any heat transfer
enhancement. Using two-dimensional, two-component particle image
velocimetry, the current work intends to characterize the heat transfer
mechanisms in pulsating flow with a mean Reynolds number of
48 by experimentally quantifying the hydrodynamics of a generic
liquid-cooled channel geometry. Flows circulated through the test
section by a gear pump are modulated using a controller to achieve
sinusoidal flow pulsations with Womersley numbers of 7.45 and
2.36 and an amplitude ratio of 0.75. It is found that the transient
characteristics of the measured velocity profiles are dependent on the
speed of oscillation, in accordance with the analytical solution for
flow in a rectangular channel. A large velocity overshoot is observed
close to the wall at high frequencies, resulting from the interaction
of near-wall viscous stresses and inertial effects of the main fluid
body. The steep velocity gradients at the wall are indicative of
augmented heat transfer, although the local flow reversal may reduce
the upstream temperature difference in heat transfer applications.
While unsteady effects remain evident at the lower frequency, the
annular effect subsides and retreats from the wall. The shear rate at
the wall is increased during the accelerating half-cycle and decreased
during deceleration compared to steady flow, suggesting that the flow
may experience both enhanced and diminished heat transfer during
a single period. Hence, the thickness of the hydrodynamic boundary
layer is reduced for positively moving flow during one half of the
pulsation cycle at the investigated frequencies. It is expected that the
size of the thermal boundary layer is similarly reduced during the
cycle, leading to intervals of heat transfer enhancement.
Abstract: In the current work, a three-dimensional geometry of a
75% stenosed blood vessel is analyzed. Large eddy simulation (LES)
with the help of a dynamic subgrid scale Smagorinsky model is
applied to model the turbulent pulsatile flow. The geometry, the
transmural pressure and the properties of the blood and the elastic
boundary were based on clinical measurement data. For the flexible
wall model, a thin solid region is constructed around the 75%
stenosed blood vessel. The deformation of this solid region was
modelled as a deforming boundary to reduce the computational cost
of the solid model. Fluid-structure interaction is realized via a twoway
coupling between the blood flow modelled via LES and the
deforming vessel. The information of the flow pressure and the wall
motion was exchanged continually during the cycle by an arbitrary
Lagrangian-Eulerian method. The boundary condition of current time
step depended on previous solutions. The fluctuation of the velocity
in the post-stenotic region was analyzed in the study. The axial
velocity at normalized position Z=0.5 shows a negative value near
the vessel wall. The displacement of the elastic boundary was
concerned in this study. In particular, the wall displacement at the
systole and the diastole were compared. The negative displacement at
the stenosis indicates a collapse at the maximum velocity and the
deceleration phase.
Abstract: In this paper, we study the pulsatile flow of blood through stenotic arteries. The inner layer of arterial walls is modeled as a porous medium and human blood is assumed as an incompressible fluid. A numerical algorithm based on the finite element method is developed to simulate the blood flow through both the lumen region and the porous wall. The algorithm is then applied to study the flow behaviour and to investigate the significance of the non-Newtonian effect.
Abstract: In this study, numerical simulations on laminar flow in
sinusoidal wavy shaped tubes were conducted for mean Reynolds
number of 250, which is in the range of physiological flow-rate and
investigated flow structures, pressure distribution and particle
trajectories both in steady and periodic inflow conditions. For
extensive comparisons, various wave lengths and amplitudes of sine
function for geometry of tube models were employed. The results
showed that small amplitude secondary curvature has significant
influence on the nature of flow patterns and particle mixing
mechanism. This implies that characterizing accurate geometry is
essential in accurate predicting of in vivo hemodynamics and may
motivate further study on any possibility of reflection of secondary
flow on vascular remodeling and pathophysiology.
Abstract: The presented paper shows the possibility of using
holographic interferometry for measurement of temperature field in
moving fluids. There are a few methods for identification of velocity
fields in fluids, such us LDA, PIV, hot wire anemometry. It is very
difficult to measure the temperature field in moving fluids. One of the
often used methods is Constant Current Anemometry (CCA), which
is a point temperature measurement method. Data are possibly
acquired at frequencies up to 1000Hz. This frequency should be
limiting factor for using of CCA in fluid when fast change of
temperature occurs. This shortcoming of CCA measurements should
be overcome by using of optical methods such as holographic
interferometry. It is necessary to employ a special holographic setup
with double sensitivity instead of the commonly used Mach-Zehnder
type of holographic interferometer in order to attain the parameters
sufficient for the studied case. This setup is not light efficient like the
Mach-Zehnder type but has double sensitivity. The special technique
of acquiring and phase averaging of results from holographic
interferometry is also presented. The results from the holographic
interferometry experiments will be compared with the temperature
field achieved by methods CCA method.
Abstract: Physiological control of a left ventricle assist device (LVAD) is generally a complicated task due to diverse operating environments and patient variability. In this work, a tracking control algorithm based on sliding mode and feed forward control for a class of discrete-time single input single output (SISO) nonlinear uncertain systems is presented. The controller was developed to track the reference trajectory to a set operating point without inducing suction in the ventricle. The controller regulates the estimated mean pulsatile flow Qp and mean pulsatility index of pump rotational speed PIω that was generated from a model of the assist device. We recall the principle of the sliding mode control theory then we combine the feed-forward control design with the sliding mode control technique to follow the reference trajectory. The uncertainty is replaced by its upper and lower boundary. The controller was tested in a computer simulation covering two scenarios (preload and ventricular contractility). The simulation results prove the effectiveness and the robustness of the proposed controller
Abstract: The recent advances in computational fluid dynamics
(CFD) can be useful in observing the detailed hemodynamics in
cerebral aneurysms for understanding not only their formation and
rupture but also for clinical evaluation and treatment. However,
important hemodynamic quantities are difficult to measure in vivo. In
the present study, an approximate model of normal middle cerebral
artery (MCA) along with two cases consisting broad and narrow
saccular aneurysms are analyzed. The models are generated in
ANSYS WORKBENCH and transient analysis is performed in
ANSYS-CFX. The results obtained are compared for three cases and
agree well with the available literature.
Abstract: Periodic vortex shedding in pulsating flow inside wavy
channel and the effect it has on heat transfer are studied using the
finite volume method. A sinusoidally-varying component is superimposed
on a uniform flow inside a sinusoidal wavy channel and
the effects on the Nusselt number is analyzed. It was found that a
unique optimum value of the pulsation frequency, represented by the
Strouhal number, exists for Reynolds numbers ranging from 125 to
1000. Results suggest that the gain in heat transfer is related to the
process of vortex formation, movement about the troughs of the wavy
channel, and subsequent ejection/destruction through the converging
section. Heat transfer is the highest when the frequencies of the
pulsation and vortex formation approach being in-phase. Analysis of
Strouhal number effect on Nu over a period of pulsation substantiates
the proposed physical mechanism for enhancement. The effect of
changing the amplitude of pulsation is also presented over a period
of pulsation, showing a monotonic increase in heat transfer with
increasing amplitude. The 60% increase in Nusselt number suggests
that sinusoidal fluid pulsation can an effective method for enhancing
heat transfer in laminar, wavy-channel flows.