Abstract: The paper presents an analytical solution for dispersion
of a solute in the peristaltic motion of a couple stress fluid
through a porous medium with slip condition in the presence of both
homogeneous and heterogeneous chemical reactions. The average
effective dispersion coefficient has been found using Taylor-s limiting
condition and long wavelength approximation. The effects of various
relevant parameters on the average coefficient of dispersion have been
studied. The average effective dispersion coefficient tends to increase
with permeability parameter but tends to decrease with homogeneous
chemical reaction rate parameter, couple stress parameter, slip parameter
and heterogeneous reaction rate parameter.
Abstract: The paper presents an analytical solution for dispersion
of a solute in the peristaltic motion of a micropolar fluid in the
presence of magnetic field and both homogeneous and heterogeneous
chemical reactions. The average effective dispersion coefficient has
been found using Taylor-s limiting condition under long wavelength
approximation. The effects of various relevant parameters on the average
coefficient of dispersion have been studied. The average effective
dispersion coefficient increases with amplitude ratio, cross viscosity
coefficient and heterogeneous chemical reaction rate parameter. But it
decreases with magnetic field parameter and homogeneous chemical
reaction rate parameter. It can be noted that the presence of peristalsis
enhances dispersion of a solute.
Abstract: The measurement of anesthetic depth is necessary in
anesthesiology. NN10 is very simple method among the RR intervals
analysis methods. NN10 parameter means the numbers of above the 10
ms intervals of the normal to normal RR intervals.
Bispectrum analysis is defined as 2D FFT. EEG signal reflected the
non-linear peristalsis phenomena according to the change brain
function. After analyzing the bispectrum of the 2 dimension, the most
significant power spectrum density peaks appeared abundantly at the
specific area in awakening and anesthesia state. These points are
utilized to create the new index since many peaks appeared at the
specific area in the frequency coordinate. The measured range of an
index was 0-100. An index is 20-50 at an anesthesia, while the index is
90-60 at the awake.
In this paper, the relation between NN10 parameter using ECG and
bisepctrum index using EEG is observed to estimate the depth of
anesthesia during anesthesia and then we estimated the utility of the
anesthetic.
Abstract: An analytical solution for dispersion of a solute in the
peristaltic motion of a couple stress fluid in the presence of magnetic
field with both homogeneous and heterogeneous chemical reactions is
presented. The average effective dispersion coefficient has been found
using Taylor-s limiting condition and long wavelength approximation.
The effects of various relevant parameters on the average effective
coefficient of dispersion have been studied. The average effective
dispersion coefficient tends to decrease with magnetic field parameter,
homogeneous chemical reaction rate parameter and amplitude ratio
but tends to increase with heterogeneous chemical reaction rate
parameter.