Abstract: The reliable results of an insulated oval duct
considering heat radiation are obtained basing on accurate oval
perimeter obtained by integral method as well as one-dimensional
Plane Wedge Thermal Resistance (PWTR) model. This is an extension
study of former paper of insulated oval duct neglecting heat radiation.
It is found that in the practical situations with long-short-axes ratio a/b
4.5% while t/R2