Abstract: This paper is intended to evaluate the structural performance of welded electronic road signs under various damage scenarios (DSs) using a finite element (FE) model calibrated with full-scale ultimate load testing results. The tested electronic road sign specimen was built with a back skin made of 5052 aluminum and two channels and a frame made of 6061 aluminum, where the back skin was connected to the frame by welding. The size of the tested specimen was 1.52 m long, 1.43 m wide, and 0.28 m deep. An actuator applied vertical loads at the center of the back skin of the specimen, resulting in a displacement of 158.7 mm and an ultimate load of 153.46 kN. Using these testing data, generation and calibration of a FE model of the tested specimen were executed in ABAQUS, indicating that the difference in the ultimate load between the calibrated model simulation and full-scale testing was only 3.32%. Then, six different DSs were simulated where the areas of the welded connection in the calibrated model were diminished for the DSs. It was found that the corners at the back skin-frame joint were prone to connection failure for all the DSs, and failure of the back skin-frame connection occurred remarkably from the distant edges.
Abstract: Background: HIV virological failure still remains a problem in HV/AIDS treatment and care. This study aimed to describe the prevalence and identify the factors associated with viral non-suppression among HIV-positive adult patients on antiretroviral therapy in Woliso Town, Oromia, Ethiopia. Methods: A retrospective cross-sectional study was conducted among 424 HIV-positive patient’s attending antiretroviral therapy (ART) in Woliso Town during the period from August 25, 2020 to August 30, 2020. Data collected from patient medical records were entered into Epi Info version 2.3.2.1 and exported to SPSS version 21.0 for analysis. Logistic regression analysis was done to identify factors associated with viral load non-suppression, and statistical significance of odds ratios were declared using 95% confidence interval and p-value < 0.05. Results: A total of 424 patients were included in this study. The mean age (± SD) of the study participants was 39.88 (± 9.995) years. The prevalence of HIV viral load non-suppression was 55 (13.0%) with 95% CI (9.9-16.5). Second-line ART treatment regimen (Adjusted Odds Ratio (AOR) = 8.98, 95% Confidence Interval (CI): 2.64, 30.58) and routine viral load testing (AOR = 0.01, 95% CI: 0.001, 0.02) were significantly associated with virological non-suppression. Conclusion: Virological non-suppression was high, which hinders the achievement of the third global 95 target. The second-line regimen and routine viral load testing were significantly associated with virological non-suppression. It suggests the need to assess the effectiveness of antiretroviral drugs for epidemic control. It also clearly shows the need to decentralize third-line ART treatment for those patients in need.
Abstract: Pile load tests should be applied to check the bearing capacity calculations and to determine the settlement of the pile corresponding to test load. Strain gauges can be installed into pile in order to determine the shaft resistance of the piles for every soil layer respectively. Detailed results can be obtained by means of strain gauges placed at certain levels into test piles. In the scope of this study, pile load test data obtained from two different projects are examined. Instrumented static pile load tests were applied on totally 7 test bored piles of different diameters (80 cm, 150 cm, and 200 cm) and different lengths (between 30-76 m) in two different project site. Settlement analysis of test piles is done by using some of load transfer methods and finite element method. Plaxis 3D which is a three-dimensional finite element program is also used for settlement analysis of the test piles. In this study, firstly bearing capacity of test piles are determined and compared with strain gauge data which is required for settlement analysis. Then, settlement values of the test piles are estimated by using load transfer methods developed in recent years and finite element method. The aim of this study is to show similarities and differences between the results obtained from settlement analysis methods and instrumented pile load tests.
Abstract: Ultimate capacity of large diameter bored piles is usually determined from pile loading tests as recommended by several international codes and foundation design standards. However, loading of this type of piles till achieving apparent failure is practically seldom. In this paper, numerical analyses are carried out to simulate load test of a large diameter bored pile performed at the location of Alzey highway bridge project (Germany). Test results of pile load settlement relationship till failure as well as results of the base and shaft resistances are available. Apparent failure was indicated in this test by the significant increase of the induced settlement during the last load increment applied on the pile head. Measurements of this pile load test are used to assess the quality of the numerical models investigated. Three different material soil models are implemented in the analyses: Mohr coulomb (MC), Soft soil (SS), and Modified Mohr coulomb (MMC). Very good agreement is obtained between the field measured settlement and the calculated settlement using the MMC model. Results of analysis showed also that the MMC constitutive model is superior to MC, and SS models in predicting the ultimate base and shaft resistances of the large diameter bored pile. After calibrating the numerical model, behavior of large diameter bored piles under axial loads is discussed and the formation of the plastic zone around the pile is explored. Results obtained showed that the plastic zone below the base of the pile at failure extended laterally to about four times the pile diameter and vertically to about three times the pile diameter.
Abstract: Socketing of bored piles in rock is always seen as a matter of debate on construction sites between consultants and contractors. The socketing depth normally depends on the type of rock, depth at which the rock is available below the pile cap and load carrying capacity of the pile. In this paper, the review of field load test data of drilled shaft socketed in weathered limestone conducted using conventional static pile load test and dynamic pile load test was made to evaluate a unit shaft friction for the bored piles socketed in weathered limestone (weak rock). The borehole drilling data were also reviewed in conjunction with the pile test result. In addition, the back-calculated unit shaft friction was reviewed against various empirical methods for bored piles socketed in weak rock. The paper concludes with an estimated ultimate unit shaft friction from the case study in Qatar for preliminary design.
Abstract: The paper presents design and production of thin-walled U-profile footbridge made of UHPFRC. The main structure of the bridge is one prefabricated shell structure made of UHPFRC with dispersed steel fibers without any conventional reinforcement. The span of the bridge structure is 10 m and the clear width of 1.5 m. The thickness of the UHPFRC shell structure oscillated in an interval of 30-45 mm. Several calculations were made during the bridge design and compared with the experiments. For the purpose of verifying the calculations, a segment of 1.5 m was first produced, followed by the whole footbridge for testing. After the load tests were done, the design was optimized to cast the final footbridge.
Abstract: Accurate determination of rock mass deformation modulus, as an important design parameter, is one of the most controversial issues in most engineering projects. A 3D numerical model of standard plate load test (PLT) using the FLAC3D code was carried to investigate the mechanism governing the test process. Five objectives were the focus of this study. The first goal was to employ 3D modeling in the interpretation of PLT conducted at the Bazoft dam site, Iran. The second objective was to investigate the effect of displacements measuring depth from the loading plates on the calculated moduli. The magnitude of rock mass deformation modulus calculated from PLT depends on anchor depth, and in practice, this may be a cause of error in the selection of realistic deformation modulus for the rock mass. The third goal of the study was to investigate the effect of testing plate diameter on the calculated modulus. Moreover, a comparison of the calculated modulus from ISRM formula, numerical modeling and calculated modulus from the actual PLT carried out at right abutment of the Bazoft dam site was another objective of the study. Finally, the effect of plastic strains on the calculated moduli in each of the loading-unloading cycles for three loading plates was investigated. The geometry, material properties, and boundary conditions on the constructed 3D model were selected based on the in-situ conditions of PLT at Bazoft dam site. A good agreement was achieved between numerical model results and the field tests results.
Abstract: Many classical bearing capacity theories assume that the natural soil's layers are homogenous for determining the bearing capacity of the soil. But, in many practical projects, we encounter multi-layer soils. Geosynthetic as reinforcement materials have been extensively used in the construction of various structures. In this paper, numerical analysis of the Plate Load Test (PLT) using of ABAQUS software in double-layered soils with different thicknesses of sandy and gravelly layers reinforced with geogrid was considered. The PLT is one of the common filed methods to calculate parameters such as soil bearing capacity, the evaluation of the compressibility and the determination of the Subgrade Reaction module. In fact, the influence of the geogrid layers on the bearing capacity of the layered soils is investigated. Finally, the most appropriate mode for the distance and number of reinforcement layers is determined. Results show that using three layers of geogrid with a distance of 0.3 times the width of the loading plate has the highest efficiency in bearing capacity of double-layer (sand and gravel) soils. Also, the significant increase in bearing capacity between unreinforced and reinforced soil with three layers of geogrid is caused by the condition that the upper layer (gravel) thickness is equal to the loading plate width.
Abstract: The present research has been performed to investigate the effect of base course application on load-settlement characteristics of sandy subgrade using plate load test. The main parameter investigated in this study was the subgrade reaction coefficient. The model tests were conducted in a 1.35 m long, 1 m wide, and 1 m deep steel test box of Imam Khomeini International University (IKIU Calibration Chamber). The base courses used in this research were in three different thicknesses of 15 cm, 20 cm, and 30 cm. The test results indicated that in the case of using base course over loose sandy subgrade, the values of subgrade reaction coefficient can be increased from 7 to 132 , 224 , and 396 in presence of 15 cm, 20 cm, and 30 cm base course, respectively.
Abstract: Today, with the daily advancement of geotechnical engineering on soil improvement and modification of the physical properties and shear strength of soil, it is now possible to construct structures with high-volume and high service load on loose sandy soils. One of such methods is using micropiles, which are mostly used to control asymmetrical subsidence, increase bearing capacity, and prevent soil liquefaction. This study examined the improvement of Anzali's saturated loose silty sand using 192 micropiles with a length of 8 meters and diameter of 75 mm. Bandar-e Anzali is one of Iran's coastal populated cities which are located in a high-seismicity region. The effects of the insertion of micropiles on prevention of liquefaction and improvement of subsidence were examined through comparison of the results of Standard Penetration Test (SPT) and Plate Load Test (PLT) before and after implementation of the micropiles. The results show that the SPT values and the ultimate bearing capacity of silty sand increased after the implementation of the micropiles. Therefore, the installation of micropiles increases the strength of silty sand improving the resistance of soil against liquefaction.
Abstract: In context of understanding problems faced by undergraduate students while carrying out laboratory experiments dealing with high voltages, it was found that most of the students are hesitant to work directly on machine. The reason is that error in the circuitry might lead to deterioration of machine and laboratory instruments. So, it has become inevitable to include modern pedagogic techniques for undergraduate students, which would help them to first carry out experiment in virtual system and then to work on live circuit. Further advantages include that students can try out their intuitive ideas and perform in virtual environment, hence leading to new research and innovations. In this paper, virtual environment used is of MATLAB/Simulink for three-phase induction machines. The performance analysis of three-phase induction machine is carried out using virtual environment which includes Direct Current (DC) Test, No-Load Test, and Block Rotor Test along with speed torque characteristics for different rotor resistances and input voltage, respectively. Further, this paper carries out computer aided teaching of basic Voltage Source Inverter (VSI) drive circuitry. Hence, this paper gave undergraduates a clearer view of experiments performed on virtual machine (No-Load test, Block Rotor test and DC test, respectively). After successful implementation of basic tests, VSI circuitry is implemented, and related harmonic distortion (THD) and Fast Fourier Transform (FFT) of current and voltage waveform are studied.
Abstract: The Cone Penetration Test (CPT) is a common in-situ
test which generally investigates a much greater volume of soil more
quickly than possible from sampling and laboratory tests. Therefore,
it has the potential to realize both cost savings and assessment of soil
properties rapidly and continuously. The principle objective of this
paper is to demonstrate the feasibility and efficiency of using
artificial neural networks (ANNs) to predict the soil angle of internal
friction (Φ) and the soil modulus of elasticity (E) from CPT results
considering the uncertainties and non-linearities of the soil. In
addition, ANNs are used to study the influence of different
parameters and recommend which parameters should be included as
input parameters to improve the prediction. Neural networks discover
relationships in the input data sets through the iterative presentation
of the data and intrinsic mapping characteristics of neural topologies.
General Regression Neural Network (GRNN) is one of the powerful
neural network architectures which is utilized in this study. A large
amount of field and experimental data including CPT results, plate
load tests, direct shear box, grain size distribution and calculated data
of overburden pressure was obtained from a large project in the
United Arab Emirates. This data was used for the training and the
validation of the neural network. A comparison was made between
the obtained results from the ANN's approach, and some common
traditional correlations that predict Φ and E from CPT results with
respect to the actual results of the collected data. The results show
that the ANN is a very powerful tool. Very good agreement was
obtained between estimated results from ANN and actual measured
results with comparison to other correlations available in the
literature. The study recommends some easily available parameters
that should be included in the estimation of the soil properties to
improve the prediction models. It is shown that the use of friction
ration in the estimation of Φ and the use of fines content in the
estimation of E considerable improve the prediction models.
Abstract: Paper presents a study about dynamic effects obtained
from the dynamic load testing of the city highway bridges in Latvia
carried out from 2005 to 2012. 9 prestressed concrete bridges and 4
composite bridges were considered. 11 of 13 bridges were designed
according to the Eurocodes but two according to the previous
structural codes used in Latvia (SNIP 2.05.03-84). The dynamic
properties of the bridges were obtained by heavy vehicle passing the
bridge roadway with different driving speeds and with or without
even pavement. The obtained values of the Dynamic amplification
factor (DAF) and the bridge natural frequency were analyzed and
compared to the values of built-in traffic load models provided in
Eurocode 1. The actual DAF values for even bridge pavement in the
most cases are smaller than the value adopted in Eurocode 1. Vehicle
speed for uneven pavements significantly influence Dynamic
amplification factor values.
Abstract: In order to verify the performance of lunar lander
structure, landing-impact test is urgently needed. And the test
equipment is necessary for the test. The functions and the key points of
the equipment are presented to satisfy the requirements of the test, and
the design scheme is proposed. The composition, the major function
and the critical parts’ design of the equipment are introduced. By the
load test of releasing device and single-beam hoist, and the
compatibility test of landing-impact testing system, the rationality and
reliability of the equipment is proved.
Abstract: In the past, there were many bridge-s collapses due to
lack of bridge structural capacity information. Most of concrete
bridge health was relied on information from visual inspection, which
sometime was inadequate. This study was conducted in order to
investigate relationship between bridge structural condition and
bridge visual condition. This study was a part of a big project
conducted at Department of Highways of Thailand. In this study, 31
bridges including slab-type bridges, plank-girder bridges, prestressed
box-beam bridges, prestressed I-girder bridges and prestressed multibeam
bridges were selected for visual inspection and load test. It was
found a positive correlation between bridge appearance and bridge-s
load carrying capacity. However, statistical characteristic revealed
low correlation between them.
Abstract: The ability to predict an accurate temperature
distribution requires the knowledge of the losses, the thermal
characteristics of the materials, and the cooling conditions, all of
which are very difficult to quantify. In this paper, the impact of the
effects of iron and copper losses are investigated separately and
their effects on the heating in various points of the stator of an
induction motor, is highlighted by using two simple tests. In addition,
the effect of a defect, such as an open circuit in a phase of the stator,
on the heating is also obtained by a no-load test.
The squirrel cage induction motor is rated at 2.2 kW; 380 V; 5.2
A; Δ connected; 50 Hz; 1420 rpm and the class of insulation F, has
been thermally tested under several load conditions. Several
thermocouples were placed in strategic points of the stator.
Abstract: Due to the high percentage of induction motors in industrial market, there exist a large opportunity for energy savings. Replacement of working induction motors with more efficient ones can be an important resource for energy savings. A calculation of energy savings and payback periods, as a result of such a replacement, based on nameplate motor efficiency or manufacture-s data can lead to large errors [1]. Efficiency of induction motors (IMs) can be extracted using some procedures that use the no-load test results. In the cases that we must estimate the efficiency on-line, some of these procedures can-t be efficient. In some cases the efficiency estimates using the rating values of the motor, but these procedures can have errors due to the different working condition of the motor. In this paper the efficiency of an IM estimated by using the genetic algorithm. The results are compared with the measured values of the torque and power. The results show smaller errors for this procedure compared with the conventional classical procedures, hence the cost of the equipments is reduced and on-line estimation of the efficiency can be made.
Abstract: The main objectives of this study are to inspect and
identify any damage of jaimusi highway prestressed concrete bridge
after repair and strengthening of damaged structural members and to
evaluate the performance of the bridge structural members by
adopting static load test. Inspection program after repair and
strengthening includes identifying and evaluating the structural
members of bridge such as T-shape cantilever structure, hanging
beams, corbels, external tendons, anchor beams, sticking steel plate,
and piers. The results of inspection show that the overall state of the
bridge structural member after repair and strengthening is good. The
results of rebound test of concrete strength show that the average
strength of concrete is 46.31Mpa. Whereas, the average value of
concrete strength of anchor beam is 49.82Mpa. According to the
results of static load test, the experimental values are less than
theoretical values of internal forces, deflection, and strain, indicating
that the stiffness of the experimental structure, overall deformation
and integrity satisfy the designed standard and the working
performance is good, and the undertaking capacity has a certain
surplus. There is not visible change in the length and width of cracks
and there are not new cracks under experimental load.
Abstract: The scale dependence of the strength of virtually homogeneous rock is usually considered to be insignificant but the spectrum of discontinuities plays a very important role for the strength of differently sized rock elements and also controls the rock creep strain. Large-scale load tests comprised recording of the creep strain rate that was found to be strongly retarded and negligible for stresses lower than about 1/3 of the failure load. For higher stresses creep took place according to a log time law representing secondary creep that ultimately changed to tertiary creep and failure.
Abstract: Text-based game is supposed to be a low resource
consumption application that delivers good performances when
compared to graphical-intensive type of games. But, nowadays, some
of the online text-based games are not offering performances that are
acceptable to the users. Therefore, an online text-based game called
Star_Quest has been developed in order to analyze its behavior under
different performance measurements. Performance metrics such as
throughput, scalability, response time and page loading time are
captured to yield the performance of the game. The techniques in
performing the load testing are also disclosed to exhibit the viability
of our work. The comparative assessment between the results
obtained and the accepted level of performances are conducted as to
determine the performance level of the game. The study reveals that
the developed game managed to meet all the performance objectives
set forth.